#include <HeatPumpWaterToWaterEquationFitHeating.hpp>
Public Member Functions | |
boost::optional < HeatPumpWaterToWaterEquationFitCooling > | companionCoolingHeatPump () const |
double | heatingCapacityCoefficient1 () const |
double | heatingCapacityCoefficient2 () const |
double | heatingCapacityCoefficient3 () const |
double | heatingCapacityCoefficient4 () const |
double | heatingCapacityCoefficient5 () const |
double | heatingCompressorPowerCoefficient1 () const |
double | heatingCompressorPowerCoefficient2 () const |
double | heatingCompressorPowerCoefficient3 () const |
double | heatingCompressorPowerCoefficient4 () const |
double | heatingCompressorPowerCoefficient5 () const |
bool | isRatedHeatingCapacityAutosized () const |
bool | isRatedHeatingPowerConsumptionAutosized () const |
bool | isReferenceLoadSideFlowRateAutosized () const |
bool | isReferenceSourceSideFlowRateAutosized () const |
boost::optional< double > | ratedHeatingCapacity () const |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Heating Capacity". More... | |
boost::optional< double > | ratedHeatingPowerConsumption () const |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Heating Power Consumption". More... | |
double | ratedLoadSideFlowRate () const |
Prior to EnergyPlus 8.7.0 this field was not autosizeable. More... | |
double | ratedSourceSideFlowRate () const |
Prior to EnergyPlus 8.7.0 this field was not autosizeable. More... | |
double | referenceCoefficientofPerformance () const |
boost::optional< double > | referenceLoadSideFlowRate () const |
boost::optional< double > | referenceSourceSideFlowRate () const |
double | sizingFactor () const |
Constructors and Destructors | |
HeatPumpWaterToWaterEquationFitHeating (const Model &model) | |
virtual | ~HeatPumpWaterToWaterEquationFitHeating () |
Setters | |
bool | setReferenceLoadSideFlowRate (double referenceLoadSideFlowRate) |
bool | setRatedLoadSideFlowRate (double ratedLoadSideFlowRate) |
Synonym of setReferenceLoadSideFlowRate for backwards compatibility. More... | |
void | autosizeReferenceLoadSideFlowRate () |
bool | setReferenceSourceSideFlowRate (double referenceSourceSideFlowRate) |
bool | setRatedSourceSideFlowRate (double ratedLoadSideFlowRate) |
Synonym of setReferenceSourceSideFlowRate for backwards compatibility. More... | |
void | autosizeReferenceSourceSideFlowRate () |
bool | setRatedHeatingCapacity (double ratedHeatingCapacity) |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Heating Capacity". More... | |
void | autosizeRatedHeatingCapacity () |
bool | setRatedHeatingPowerConsumption (double ratedHeatingPowerConsumption) |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Heating Power Consumption". More... | |
void | autosizeRatedHeatingPowerConsumption () |
bool | setHeatingCapacityCoefficient1 (double heatingCapacityCoefficient1) |
bool | setHeatingCapacityCoefficient2 (double heatingCapacityCoefficient2) |
bool | setHeatingCapacityCoefficient3 (double heatingCapacityCoefficient3) |
bool | setHeatingCapacityCoefficient4 (double heatingCapacityCoefficient4) |
bool | setHeatingCapacityCoefficient5 (double heatingCapacityCoefficient5) |
bool | setHeatingCompressorPowerCoefficient1 (double heatingCompressorPowerCoefficient1) |
bool | setHeatingCompressorPowerCoefficient2 (double heatingCompressorPowerCoefficient2) |
bool | setHeatingCompressorPowerCoefficient3 (double heatingCompressorPowerCoefficient3) |
bool | setHeatingCompressorPowerCoefficient4 (double heatingCompressorPowerCoefficient4) |
bool | setHeatingCompressorPowerCoefficient5 (double heatingCompressorPowerCoefficient5) |
bool | setReferenceCoefficientofPerformance (double referenceCoefficientofPerformance) |
bool | setSizingFactor (double sizingFactor) |
bool | setCompanionCoolingHeatPump (const HeatPumpWaterToWaterEquationFitCooling &companionHP) |
Other | |
boost::optional< double > | autosizedReferenceLoadSideFlowRate () const |
boost::optional< double > | autosizedReferenceSourceSideFlowRate () const |
boost::optional< double > | autosizedRatedHeatingCapacity () const |
boost::optional< double > | autosizedRatedHeatingPowerConsumption () const |
Public Member Functions inherited from openstudio::model::WaterToWaterComponent | |
virtual bool | addToNode (Node &node) |
virtual bool | addToTertiaryNode (Node &node) |
Add this WaterToWaterComponent to a tertiaryPlantLoop by making connections to the tertiary inlet and outlet. More... | |
virtual ModelObject | clone (Model model) const |
virtual boost::optional < ModelObject > | demandInletModelObject () const |
Returns the optional ModelObject connected to the demand inlet port. More... | |
virtual unsigned | demandInletPort () const |
Returns the demand inlet port. More... | |
virtual boost::optional < ModelObject > | demandOutletModelObject () const |
Returns the optional ModelObject connected to the demand outlet port. More... | |
virtual unsigned | demandOutletPort () const |
Returns the demand outlet port. More... | |
void | disconnect () |
boost::optional< PlantLoop > | plantLoop () const |
Returns the optional PlantLoop object that the HVAC component is a supply component on. More... | |
virtual std::vector < openstudio::IdfObject > | remove () |
bool | removeFromPlantLoop () |
Removes the component from the plantLoop if one is attached. More... | |
bool | removeFromSecondaryPlantLoop () |
Removes the component from the secondaryPlantLoop if one is attached. More... | |
bool | removeFromTertiaryPlantLoop () |
Removes the component from the tertiaryPlantLoop if one is attached. More... | |
boost::optional< PlantLoop > | secondaryPlantLoop () const |
Returns the optional PlantLoop object that the HVAC component is a demand component on. More... | |
virtual boost::optional < ModelObject > | supplyInletModelObject () const |
Returns the optional ModelObject connected to the supply inlet port. More... | |
virtual unsigned | supplyInletPort () const |
Returns the supply inlet port. More... | |
virtual boost::optional < ModelObject > | supplyOutletModelObject () const |
Returns the optional ModelObject connected to the supply outlet port. More... | |
virtual unsigned | supplyOutletPort () const |
Returns the supply outlet port. More... | |
boost::optional< ModelObject > | tertiaryInletModelObject () const |
Returns the optional ModelObject connected to the tertiary inlet. More... | |
boost::optional< ModelObject > | tertiaryOutletModelObject () const |
Returns the optional ModelObject connected to the tertiary outlet. More... | |
boost::optional< PlantLoop > | tertiaryPlantLoop () const |
Tertiary plant loop applies to a limited number of WaterToWaterComponent types that interact with three plant systems. More... | |
WaterToWaterComponent (IddObjectType type, const Model &model) | |
virtual | ~WaterToWaterComponent () |
Public Member Functions inherited from openstudio::model::HVACComponent | |
bool | addToNode (Node &node) |
Adds this object to a new system node and returns a boolean indicating if the addition was successful. More... | |
bool | addToSplitter (Splitter &splitter) |
Adds this object to a splitter by creating a new branch. More... | |
boost::optional< AirLoopHVAC > | airLoopHVAC () const |
Returns the optional AirLoopHVAC object that the HVAC component is attached to. More... | |
boost::optional < AirLoopHVACOutdoorAirSystem > | airLoopHVACOutdoorAirSystem () const |
Returns the optional AirLoopHVACOutdoorAirSystem that the HVAC component is attached to. More... | |
void | applySizingValues () |
void | autosize () |
Returns the optional ModelObject connected to this object's port. More... | |
boost::optional< HVACComponent > | containingHVACComponent () const |
EnergyPlus unitary equipment and air terminals are typically composed of other HVAC components. More... | |
boost::optional < StraightComponent > | containingStraightComponent () const |
boost::optional < ZoneHVACComponent > | containingZoneHVACComponent () const |
Returns any ZoneHVACComponent that contains this HVACComponent. More... | |
void | disconnect () |
Removes all connections to other HVACComponent objects. More... | |
bool | isRemovable () const |
Indicates if the HVACComponent can be removed from the model. More... | |
boost::optional< Loop > | loop () const |
Returns the optional Loop object that the HVAC component is attached to. More... | |
boost::optional< PlantLoop > | plantLoop () const |
Returns the optional PlantLoop object that the HVAC component is attached to. More... | |
std::vector< IdfObject > | remove () |
Removes the HVACComponent from the model only if isRemovable() return true. More... | |
virtual | ~HVACComponent () |
Public Member Functions inherited from openstudio::model::ParentObject | |
std::vector< IddObjectType > | allowableChildTypes () const |
Returns a vector of allowable children types. More... | |
std::vector< ModelObject > | children () const |
Return direct child objects in the Model. More... | |
virtual | ~ParentObject () |
Public Member Functions inherited from openstudio::model::ModelObject | |
virtual | ~ModelObject () |
ModelObject | clone () const |
Creates a deep copy of this object, placing it in this object's model(). More... | |
ModelObject | clone (Model model) const |
Creates a deep copy of this object, placing it in model. More... | |
Component | createComponent () const |
Method for creating sharable Model snippets. More... | |
Model | model () const |
Returns the Model that contains this object. More... | |
boost::optional< ParentObject > | parent () const |
Return this object's parent in the hierarchy, if it has one. More... | |
std::vector< ResourceObject > | resources () const |
Get the resources directly used by this ModelObject. More... | |
template<typename T > | |
std::vector< T > | getModelObjectSources () const |
Get all objects of type T that point to this object. More... | |
template<typename T > | |
std::vector< T > | getModelObjectSources (IddObjectType iddObjectType) const |
Get all objects of type T that point to this object. More... | |
template<typename T > | |
boost::optional< T > | getModelObjectTarget (unsigned index) const |
Get the object of type T pointed to by this object from field index. More... | |
template<typename T > | |
std::vector< T > | getModelObjectTargets () const |
Get all objects of type T to which this object points. More... | |
const std::vector< std::string > & | outputVariableNames () const |
Get all output variables names that could be associated with this object. More... | |
std::vector< OutputVariable > | outputVariables () const |
Get all output variables associated with this object, must run simulation to generate data. More... | |
boost::optional < openstudio::TimeSeries > | getData (const OutputVariable &variable, const std::string &envPeriod) const |
Get data associated with this output variable and this object. More... | |
std::vector< LifeCycleCost > | lifeCycleCosts () const |
Returns the list of all LifeCycleCosts that refer to this object. More... | |
std::vector< IdfObject > | removeLifeCycleCosts () |
Removes all LifeCycleCosts that refer to this object. More... | |
IddObjectType | iddObjectType () const |
This is a virtual function that will tell you the type of iddObject you are dealing with. More... | |
AdditionalProperties | additionalProperties () const |
Returns this object's additional properties, constructing a new object if necessary. More... | |
bool | hasAdditionalProperties () const |
Returns true if this object has additional properties. More... | |
std::vector< IdfObject > | removeAdditionalProperties () |
Removes all additional properties that refer to this object. More... | |
bool | setParent (ParentObject &newParent) |
set the parent, child may have to call non-const methods on the parent More... | |
bool | operator< (const ModelObject &right) const |
bool | operator== (const ModelObject &other) const |
equality test More... | |
bool | operator!= (const ModelObject &other) const |
inequality test More... | |
std::vector< ScheduleTypeKey > | getScheduleTypeKeys (const Schedule &schedule) const |
Return the ScheduleTypeKeys indicating how schedule is used in this object. More... | |
boost::optional< double > | getAutosizedValue (std::string valueName, std::string unitString) const |
Gets the autosized component value from the sql file. More... | |
virtual std::vector < EMSActuatorNames > | emsActuatorNames () const |
Return the names of the available ems actuators. More... | |
virtual std::vector< std::string > | emsInternalVariableNames () const |
Return the names of the available ems internal variables. More... | |
boost::optional< ModelObject > | connectedObject (unsigned port) const |
boost::optional< unsigned > | connectedObjectPort (unsigned port) const |
Static Public Member Functions | |
static IddObjectType | iddObjectType () |
Related Functions | |
(Note that these are not member functions.) | |
typedef std::vector < HeatPumpWaterToWaterEquationFitHeating > | HeatPumpWaterToWaterEquationFitHeatingVector |
typedef boost::optional < HeatPumpWaterToWaterEquationFitHeating > | OptionalHeatPumpWaterToWaterEquationFitHeating |
Related Functions inherited from openstudio::model::ParentObject | |
std::vector< ModelObject > | getRecursiveChildren (const ParentObject &object, bool includeLifeCycleCostsAndAdditionalProperties=false) |
Returns object and all other objects accessible by calling children() on encountered ParentObjects . More... | |
std::vector< ModelObject > | getRecursiveChildrenAndResources (const ModelObject &object) |
Returns object and all other objects accessible by calling children() and resources() on encountered ModelObjects . More... | |
Related Functions inherited from openstudio::model::ModelObject | |
std::vector< ResourceObject > | getRecursiveResources (const ModelObject &object) |
Returns all ResourceObjects accessible by recursively calling .resources() starting from object. More... | |
typedef std::pair< std::string, std::string > | ScheduleTypeKey |
Typedef for ScheduleTypeRegistry key. More... | |
typedef std::pair< std::string, std::string > | ScheduleTypeKey |
Typedef for ScheduleTypeRegistry key. More... | |
Additional Inherited Members | |
Protected Types inherited from openstudio::model::HVACComponent | |
typedef detail::HVACComponent_Impl | ImplType |
Protected Types inherited from openstudio::model::ModelObject | |
typedef detail::ModelObject_Impl | ImplType |
Protected Member Functions inherited from openstudio::model::HVACComponent | |
virtual std::vector< ModelObject > | children () const |
HVACComponent (IddObjectType type, const Model &model) | |
HVACComponent (std::shared_ptr< ImplType > impl) | |
Protected Member Functions inherited from openstudio::model::ParentObject | |
ParentObject (IddObjectType type, const Model &model) | |
Constructs a new ParentObject object in the model. More... | |
Protected Member Functions inherited from openstudio::model::ModelObject | |
ModelObject (IddObjectType type, const Model &model, bool fastName=false) | |
ModelObject (std::shared_ptr< detail::ModelObject_Impl > impl) | |
HeatPumpWaterToWaterEquationFitHeating is a WaterToWaterComponent that wraps the OpenStudio IDD object 'OS:HeatPump:WaterToWater:EquationFit:Heating'.
|
explicit |
|
inlinevirtual |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitHeating::autosizedRatedHeatingCapacity | ( | ) | const |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitHeating::autosizedRatedHeatingPowerConsumption | ( | ) | const |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitHeating::autosizedReferenceLoadSideFlowRate | ( | ) | const |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitHeating::autosizedReferenceSourceSideFlowRate | ( | ) | const |
void openstudio::model::HeatPumpWaterToWaterEquationFitHeating::autosizeRatedHeatingCapacity | ( | ) |
void openstudio::model::HeatPumpWaterToWaterEquationFitHeating::autosizeRatedHeatingPowerConsumption | ( | ) |
void openstudio::model::HeatPumpWaterToWaterEquationFitHeating::autosizeReferenceLoadSideFlowRate | ( | ) |
void openstudio::model::HeatPumpWaterToWaterEquationFitHeating::autosizeReferenceSourceSideFlowRate | ( | ) |
boost::optional<HeatPumpWaterToWaterEquationFitCooling> openstudio::model::HeatPumpWaterToWaterEquationFitHeating::companionCoolingHeatPump | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::heatingCapacityCoefficient1 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::heatingCapacityCoefficient2 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::heatingCapacityCoefficient3 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::heatingCapacityCoefficient4 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::heatingCapacityCoefficient5 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::heatingCompressorPowerCoefficient1 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::heatingCompressorPowerCoefficient2 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::heatingCompressorPowerCoefficient3 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::heatingCompressorPowerCoefficient4 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::heatingCompressorPowerCoefficient5 | ( | ) | const |
|
static |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::isRatedHeatingCapacityAutosized | ( | ) | const |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::isRatedHeatingPowerConsumptionAutosized | ( | ) | const |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::isReferenceLoadSideFlowRateAutosized | ( | ) | const |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::isReferenceSourceSideFlowRateAutosized | ( | ) | const |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitHeating::ratedHeatingCapacity | ( | ) | const |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Heating Capacity".
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitHeating::ratedHeatingPowerConsumption | ( | ) | const |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Heating Power Consumption".
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::ratedLoadSideFlowRate | ( | ) | const |
Prior to EnergyPlus 8.7.0 this field was not autosizeable.
To preserve backwards compatibility this method will return -999.0 in autosized models.
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::ratedSourceSideFlowRate | ( | ) | const |
Prior to EnergyPlus 8.7.0 this field was not autosizeable.
To preserve backwards compatibility this method will return -999.0 in autosized models.
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::referenceCoefficientofPerformance | ( | ) | const |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitHeating::referenceLoadSideFlowRate | ( | ) | const |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitHeating::referenceSourceSideFlowRate | ( | ) | const |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setCompanionCoolingHeatPump | ( | const HeatPumpWaterToWaterEquationFitCooling & | companionHP | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setHeatingCapacityCoefficient1 | ( | double | heatingCapacityCoefficient1 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setHeatingCapacityCoefficient2 | ( | double | heatingCapacityCoefficient2 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setHeatingCapacityCoefficient3 | ( | double | heatingCapacityCoefficient3 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setHeatingCapacityCoefficient4 | ( | double | heatingCapacityCoefficient4 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setHeatingCapacityCoefficient5 | ( | double | heatingCapacityCoefficient5 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setHeatingCompressorPowerCoefficient1 | ( | double | heatingCompressorPowerCoefficient1 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setHeatingCompressorPowerCoefficient2 | ( | double | heatingCompressorPowerCoefficient2 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setHeatingCompressorPowerCoefficient3 | ( | double | heatingCompressorPowerCoefficient3 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setHeatingCompressorPowerCoefficient4 | ( | double | heatingCompressorPowerCoefficient4 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setHeatingCompressorPowerCoefficient5 | ( | double | heatingCompressorPowerCoefficient5 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setRatedHeatingCapacity | ( | double | ratedHeatingCapacity | ) |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Heating Capacity".
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setRatedHeatingPowerConsumption | ( | double | ratedHeatingPowerConsumption | ) |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Heating Power Consumption".
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setRatedLoadSideFlowRate | ( | double | ratedLoadSideFlowRate | ) |
Synonym of setReferenceLoadSideFlowRate for backwards compatibility.
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setRatedSourceSideFlowRate | ( | double | ratedLoadSideFlowRate | ) |
Synonym of setReferenceSourceSideFlowRate for backwards compatibility.
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setReferenceCoefficientofPerformance | ( | double | referenceCoefficientofPerformance | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setReferenceLoadSideFlowRate | ( | double | referenceLoadSideFlowRate | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setReferenceSourceSideFlowRate | ( | double | referenceSourceSideFlowRate | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitHeating::setSizingFactor | ( | double | sizingFactor | ) |
double openstudio::model::HeatPumpWaterToWaterEquationFitHeating::sizingFactor | ( | ) | const |
|
related |
|
related |