additionalProperties() const | openstudio::model::ModelObject | |
addToNode(Node &node) | openstudio::model::WaterToWaterComponent | virtual |
addToSplitter(Splitter &splitter) | openstudio::model::HVACComponent | |
addToTertiaryNode(Node &node) | openstudio::model::WaterToWaterComponent | virtual |
airLoopHVAC() const | openstudio::model::HVACComponent | |
airLoopHVACOutdoorAirSystem() const | openstudio::model::HVACComponent | |
allowableChildTypes() const | openstudio::model::ParentObject | |
applySizingValues() | openstudio::model::HVACComponent | |
autosize() | openstudio::model::HVACComponent | |
autosizedDesignHeatRecoveryWaterFlowRate() const | openstudio::model::ChillerElectricEIR | |
autosizeDesignHeatRecoveryWaterFlowRate() | openstudio::model::ChillerElectricEIR | |
autosizedReferenceCapacity() const | openstudio::model::ChillerElectricEIR | |
autosizedReferenceChilledWaterFlowRate() const | openstudio::model::ChillerElectricEIR | |
autosizedReferenceCondenserFluidFlowRate() const | openstudio::model::ChillerElectricEIR | |
autosizeReferenceCapacity() | openstudio::model::ChillerElectricEIR | |
autosizeReferenceChilledWaterFlowRate() | openstudio::model::ChillerElectricEIR | |
autosizeReferenceCondenserFluidFlowRate() | openstudio::model::ChillerElectricEIR | |
basinHeaterCapacity() const | openstudio::model::ChillerElectricEIR | |
basinHeaterSchedule() const | openstudio::model::ChillerElectricEIR | |
basinHeaterSetpointTemperature() const | openstudio::model::ChillerElectricEIR | |
cadObjectId() const | openstudio::model::ModelObject | |
children() const | openstudio::model::HVACComponent | protectedvirtual |
chilledWaterLoop() const | openstudio::model::ChillerElectricEIR | |
ChillerElectricEIR(const Model &model, const CurveBiquadratic &CCFofT, const CurveBiquadratic &EItoCORFofT, const CurveQuadratic &EItoCORFofPLR) | openstudio::model::ChillerElectricEIR | explicit |
ChillerElectricEIR(const Model &model) | openstudio::model::ChillerElectricEIR | explicit |
ChillerElectricEIRVector typedef | openstudio::model::ChillerElectricEIR | related |
chillerFlowMode() const | openstudio::model::ChillerElectricEIR | |
clone(Model model) const | openstudio::model::WaterToWaterComponent | virtual |
openstudio::model::HVACComponent::clone() const | openstudio::model::ModelObject | |
condenserFanPowerRatio() const | openstudio::model::ChillerElectricEIR | |
condenserHeatRecoveryRelativeCapacityFraction() const | openstudio::model::ChillerElectricEIR | |
condenserType() const | openstudio::model::ChillerElectricEIR | |
condenserWaterLoop() const | openstudio::model::ChillerElectricEIR | |
connectedObject(unsigned port) const | openstudio::model::ModelObject | |
connectedObjectPort(unsigned port) const | openstudio::model::ModelObject | |
containingHVACComponent() const | openstudio::model::HVACComponent | |
containingStraightComponent() const | openstudio::model::HVACComponent | |
containingZoneHVACComponent() const | openstudio::model::HVACComponent | |
coolingCapacityFunctionOfTemperature() const | openstudio::model::ChillerElectricEIR | |
createComponent() const | openstudio::model::ModelObject | |
demandInletModelObject() const | openstudio::model::WaterToWaterComponent | virtual |
demandInletPort() const | openstudio::model::WaterToWaterComponent | virtual |
demandOutletModelObject() const | openstudio::model::WaterToWaterComponent | virtual |
demandOutletPort() const | openstudio::model::WaterToWaterComponent | virtual |
designHeatRecoveryWaterFlowRate() const | openstudio::model::ChillerElectricEIR | |
disconnect() | openstudio::model::WaterToWaterComponent | |
displayName() const | openstudio::model::ModelObject | |
electricInputToCoolingOutputRatioFunctionOfPLR() const | openstudio::model::ChillerElectricEIR | |
electricInputToCoolingOutputRatioFunctionOfTemperature() const | openstudio::model::ChillerElectricEIR | |
emsActuatorNames() const | openstudio::model::ModelObject | virtual |
emsInternalVariableNames() const | openstudio::model::ModelObject | virtual |
endUseSubcategory() const | openstudio::model::ChillerElectricEIR | |
fractionofCompressorElectricConsumptionRejectedbyCondenser() const | openstudio::model::ChillerElectricEIR | |
gbXMLId() const | openstudio::model::ModelObject | |
getAutosizedValue(std::string valueName, std::string unitString) const | openstudio::model::ModelObject | |
getData(const OutputVariable &variable, const std::string &envPeriod) const | openstudio::model::ModelObject | |
getModelObjectSources() const | openstudio::model::ModelObject | inline |
getModelObjectSources(IddObjectType iddObjectType) const | openstudio::model::ModelObject | inline |
getModelObjectTarget(unsigned index) const | openstudio::model::ModelObject | inline |
getModelObjectTargets() const | openstudio::model::ModelObject | inline |
getRecursiveChildren(const ParentObject &object, bool includeLifeCycleCostsAndAdditionalProperties=false, bool includeUsedResources=true) | openstudio::model::ParentObject | related |
getRecursiveChildrenAndResources(const ModelObject &object) | openstudio::model::ParentObject | related |
getRecursiveResources(const ModelObject &object) | openstudio::model::ModelObject | related |
getScheduleTypeKeys(const Schedule &schedule) const | openstudio::model::ModelObject | |
hasAdditionalProperties() const | openstudio::model::ModelObject | |
heatRecoveryInletHighTemperatureLimitSchedule() const | openstudio::model::ChillerElectricEIR | |
heatRecoveryLeavingTemperatureSetpointNode() const | openstudio::model::ChillerElectricEIR | |
heatRecoveryLoop() const | openstudio::model::ChillerElectricEIR | |
HVACComponent(IddObjectType type, const Model &model) | openstudio::model::HVACComponent | protected |
HVACComponent(std::shared_ptr< ImplType > impl) | openstudio::model::HVACComponent | explicitprotected |
iddObjectType() | openstudio::model::ChillerElectricEIR | static |
openstudio::model::WaterToWaterComponent::iddObjectType() const | openstudio::model::ModelObject | |
ImplType typedef | openstudio::model::HVACComponent | protected |
isBasinHeaterCapacityDefaulted() const | openstudio::model::ChillerElectricEIR | |
isBasinHeaterSetpointTemperatureDefaulted() const | openstudio::model::ChillerElectricEIR | |
isChillerFlowModeDefaulted() const | openstudio::model::ChillerElectricEIR | |
isCondenserFanPowerRatioDefaulted() const | openstudio::model::ChillerElectricEIR | |
isCondenserTypeDefaulted() const | openstudio::model::ChillerElectricEIR | |
isDesignHeatRecoveryWaterFlowRateAutosized() const | openstudio::model::ChillerElectricEIR | |
isFractionofCompressorElectricConsumptionRejectedbyCondenserDefaulted() const | openstudio::model::ChillerElectricEIR | |
isLeavingChilledWaterLowerTemperatureLimitDefaulted() const | openstudio::model::ChillerElectricEIR | |
isMaximumPartLoadRatioDefaulted() const | openstudio::model::ChillerElectricEIR | |
isMinimumPartLoadRatioDefaulted() const | openstudio::model::ChillerElectricEIR | |
isMinimumUnloadingRatioDefaulted() const | openstudio::model::ChillerElectricEIR | |
isOptimumPartLoadRatioDefaulted() const | openstudio::model::ChillerElectricEIR | |
isReferenceCapacityAutosized() const | openstudio::model::ChillerElectricEIR | |
isReferenceChilledWaterFlowRateAutosized() const | openstudio::model::ChillerElectricEIR | |
isReferenceCondenserFluidFlowRateAutosized() const | openstudio::model::ChillerElectricEIR | |
isReferenceEnteringCondenserFluidTemperatureDefaulted() const | openstudio::model::ChillerElectricEIR | |
isReferenceLeavingChilledWaterTemperatureDefaulted() const | openstudio::model::ChillerElectricEIR | |
isRemovable() const | openstudio::model::HVACComponent | |
isSizingFactorDefaulted() const | openstudio::model::ChillerElectricEIR | |
leavingChilledWaterLowerTemperatureLimit() const | openstudio::model::ChillerElectricEIR | |
lifeCycleCosts() const | openstudio::model::ModelObject | |
loop() const | openstudio::model::HVACComponent | |
maximumPartLoadRatio() const | openstudio::model::ChillerElectricEIR | |
minimumPartLoadRatio() const | openstudio::model::ChillerElectricEIR | |
minimumUnloadingRatio() const | openstudio::model::ChillerElectricEIR | |
model() const | openstudio::model::ModelObject | |
ModelObject(IddObjectType type, const Model &model, bool fastName=false) | openstudio::model::ModelObject | explicitprotected |
ModelObject(std::shared_ptr< detail::ModelObject_Impl > impl) | openstudio::model::ModelObject | explicitprotected |
operator!=(const ModelObject &other) const | openstudio::model::ModelObject | |
operator<(const ModelObject &right) const | openstudio::model::ModelObject | |
operator==(const ModelObject &other) const | openstudio::model::ModelObject | |
optimumPartLoadRatio() const | openstudio::model::ChillerElectricEIR | |
OptionalChillerElectricEIR typedef | openstudio::model::ChillerElectricEIR | related |
outputVariableNames() const | openstudio::model::ModelObject | |
outputVariables() const | openstudio::model::ModelObject | |
parent() const | openstudio::model::ModelObject | |
ParentObject(IddObjectType type, const Model &model) | openstudio::model::ParentObject | protected |
plantLoop() const | openstudio::model::WaterToWaterComponent | |
referenceCapacity() const | openstudio::model::ChillerElectricEIR | |
referenceChilledWaterFlowRate() const | openstudio::model::ChillerElectricEIR | |
referenceCondenserFluidFlowRate() const | openstudio::model::ChillerElectricEIR | |
referenceCOP() const | openstudio::model::ChillerElectricEIR | |
referenceEnteringCondenserFluidTemperature() const | openstudio::model::ChillerElectricEIR | |
referenceLeavingChilledWaterTemperature() const | openstudio::model::ChillerElectricEIR | |
remove() | openstudio::model::WaterToWaterComponent | virtual |
removeAdditionalProperties() | openstudio::model::ModelObject | |
removeFromPlantLoop() | openstudio::model::WaterToWaterComponent | |
removeFromSecondaryPlantLoop() | openstudio::model::WaterToWaterComponent | |
removeFromTertiaryPlantLoop() | openstudio::model::WaterToWaterComponent | |
removeLifeCycleCosts() | openstudio::model::ModelObject | |
resetBasinHeaterCapacity() | openstudio::model::ChillerElectricEIR | |
resetBasinHeaterSchedule() | openstudio::model::ChillerElectricEIR | |
resetBasinHeaterSetpointTemperature() | openstudio::model::ChillerElectricEIR | |
resetChillerFlowMode() | openstudio::model::ChillerElectricEIR | |
resetCondenserFanPowerRatio() | openstudio::model::ChillerElectricEIR | |
resetCondenserType() | openstudio::model::ChillerElectricEIR | |
resetFractionofCompressorElectricConsumptionRejectedbyCondenser() | openstudio::model::ChillerElectricEIR | |
resetHeatRecoveryInletHighTemperatureLimitSchedule() | openstudio::model::ChillerElectricEIR | |
resetHeatRecoveryLeavingTemperatureSetpointNode() | openstudio::model::ChillerElectricEIR | |
resetLeavingChilledWaterLowerTemperatureLimit() | openstudio::model::ChillerElectricEIR | |
resetMaximumPartLoadRatio() | openstudio::model::ChillerElectricEIR | |
resetMinimumPartLoadRatio() | openstudio::model::ChillerElectricEIR | |
resetMinimumUnloadingRatio() | openstudio::model::ChillerElectricEIR | |
resetOptimumPartLoadRatio() | openstudio::model::ChillerElectricEIR | |
resetReferenceChilledWaterFlowRate() | openstudio::model::ChillerElectricEIR | |
resetReferenceCondenserFluidFlowRate() | openstudio::model::ChillerElectricEIR | |
resetReferenceEnteringCondenserFluidTemperature() | openstudio::model::ChillerElectricEIR | |
resetReferenceLeavingChilledWaterTemperature() | openstudio::model::ChillerElectricEIR | |
resetSizingFactor() | openstudio::model::ChillerElectricEIR | |
resources() const | openstudio::model::ModelObject | |
secondaryPlantLoop() const | openstudio::model::WaterToWaterComponent | |
setBasinHeaterCapacity(double basinHeaterCapacity) | openstudio::model::ChillerElectricEIR | |
setBasinHeaterSchedule(Schedule &s) | openstudio::model::ChillerElectricEIR | |
setBasinHeaterSetpointTemperature(double basinHeaterSetpointTemperature) | openstudio::model::ChillerElectricEIR | |
setCADObjectId(const std::string &cadObjectId) | openstudio::model::ModelObject | |
setChillerFlowMode(std::string chillerFlowMode) | openstudio::model::ChillerElectricEIR | |
setCondenserFanPowerRatio(double condenserFanPowerRatio) | openstudio::model::ChillerElectricEIR | |
setCondenserHeatRecoveryRelativeCapacityFraction(double condenserHeatRecoveryRelativeCapacityFraction) | openstudio::model::ChillerElectricEIR | |
setCondenserType(std::string condenserType) | openstudio::model::ChillerElectricEIR | |
setCoolingCapacityFunctionOfTemperature(const CurveBiquadratic &) | openstudio::model::ChillerElectricEIR | |
setDesignHeatRecoveryWaterFlowRate(double designHeatRecoveryWaterFlowRate) | openstudio::model::ChillerElectricEIR | |
setDisplayName(const std::string &displayName) | openstudio::model::ModelObject | |
setElectricInputToCoolingOutputRatioFunctionOfPLR(const CurveQuadratic &) | openstudio::model::ChillerElectricEIR | |
setElectricInputToCoolingOutputRatioFunctionOfTemperature(const CurveBiquadratic &) | openstudio::model::ChillerElectricEIR | |
setEndUseSubcategory(const std::string &endUseSubcategory) | openstudio::model::ChillerElectricEIR | |
setFractionofCompressorElectricConsumptionRejectedbyCondenser(double fractionofCompressorElectricConsumptionRejectedbyCondenser) | openstudio::model::ChillerElectricEIR | |
setGBXMLId(const std::string &gbXMLId) | openstudio::model::ModelObject | |
setHeatRecoveryInletHighTemperatureLimitSchedule(Schedule &s) | openstudio::model::ChillerElectricEIR | |
setHeatRecoveryLeavingTemperatureSetpointNode(const Node &node) | openstudio::model::ChillerElectricEIR | |
setLeavingChilledWaterLowerTemperatureLimit(double leavingChilledWaterLowerTemperatureLimit) | openstudio::model::ChillerElectricEIR | |
setMaximumPartLoadRatio(double maximumPartLoadRatio) | openstudio::model::ChillerElectricEIR | |
setMinimumPartLoadRatio(double minimumPartLoadRatio) | openstudio::model::ChillerElectricEIR | |
setMinimumUnloadingRatio(double minimumUnloadingRatio) | openstudio::model::ChillerElectricEIR | |
setOptimumPartLoadRatio(double optimumPartLoadRatio) | openstudio::model::ChillerElectricEIR | |
setParent(ParentObject &newParent) | openstudio::model::ModelObject | |
setReferenceCapacity(boost::optional< double > referenceCapacity) | openstudio::model::ChillerElectricEIR | |
setReferenceCapacity(double referenceCapacity) | openstudio::model::ChillerElectricEIR | |
setReferenceChilledWaterFlowRate(boost::optional< double > referenceChilledWaterFlowRate) | openstudio::model::ChillerElectricEIR | |
setReferenceChilledWaterFlowRate(double referenceChilledWaterFlowRate) | openstudio::model::ChillerElectricEIR | |
setReferenceCondenserFluidFlowRate(boost::optional< double > referenceCondenserFluidFlowRate) | openstudio::model::ChillerElectricEIR | |
setReferenceCondenserFluidFlowRate(double referenceCondenserFluidFlowRate) | openstudio::model::ChillerElectricEIR | |
setReferenceCOP(double referenceCOP) | openstudio::model::ChillerElectricEIR | |
setReferenceEnteringCondenserFluidTemperature(double referenceEnteringCondenserFluidTemperature) | openstudio::model::ChillerElectricEIR | |
setReferenceLeavingChilledWaterTemperature(double referenceLeavingChilledWaterTemperature) | openstudio::model::ChillerElectricEIR | |
setSizingFactor(double sizingFactor) | openstudio::model::ChillerElectricEIR | |
sizingFactor() const | openstudio::model::ChillerElectricEIR | |
supplyInletModelObject() const | openstudio::model::WaterToWaterComponent | virtual |
supplyInletPort() const | openstudio::model::WaterToWaterComponent | virtual |
supplyOutletModelObject() const | openstudio::model::WaterToWaterComponent | virtual |
supplyOutletPort() const | openstudio::model::WaterToWaterComponent | virtual |
tertiaryInletModelObject() const | openstudio::model::WaterToWaterComponent | |
tertiaryOutletModelObject() const | openstudio::model::WaterToWaterComponent | |
tertiaryPlantLoop() const | openstudio::model::WaterToWaterComponent | |
validChillerFlowModeValues() | openstudio::model::ChillerElectricEIR | static |
validCondenserTypeValues() | openstudio::model::ChillerElectricEIR | static |
WaterToWaterComponent(IddObjectType type, const Model &model) | openstudio::model::WaterToWaterComponent | |
~ChillerElectricEIR() | openstudio::model::ChillerElectricEIR | inlinevirtual |
~HVACComponent() | openstudio::model::HVACComponent | inlinevirtual |
~ModelObject() | openstudio::model::ModelObject | inlinevirtual |
~ParentObject() | openstudio::model::ParentObject | inlinevirtual |
~WaterToWaterComponent() | openstudio::model::WaterToWaterComponent | inlinevirtual |