#include <ZoneHVACWaterToAirHeatPump.hpp>
Public Member Functions | |
Constructors and Destructors | |
ZoneHVACWaterToAirHeatPump (const Model &model, Schedule &availabilitySchedule, HVACComponent &supplyAirFan, HVACComponent &heatingCoil, HVACComponent &coolingCoil, HVACComponent &supplementalHeatingCoil) | |
virtual | ~ZoneHVACWaterToAirHeatPump () |
Getters | |
Schedule | availabilitySchedule () const |
boost::optional< double > | supplyAirFlowRateDuringCoolingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Supply Air Flow Rate". More... | |
bool | isSupplyAirFlowRateDuringCoolingOperationAutosized () const |
boost::optional< double > | supplyAirFlowRateDuringHeatingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Supply Air Flow Rate". More... | |
bool | isSupplyAirFlowRateDuringHeatingOperationAutosized () const |
boost::optional< double > | supplyAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Supply Air Flow Rate". More... | |
bool | isSupplyAirFlowRateWhenNoCoolingorHeatingisNeededAutosized () const |
boost::optional< double > | outdoorAirFlowRateDuringCoolingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Outdoor Air Flow Rate". More... | |
bool | isOutdoorAirFlowRateDuringCoolingOperationAutosized () const |
boost::optional< double > | outdoorAirFlowRateDuringHeatingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Outdoor Air Flow Rate". More... | |
bool | isOutdoorAirFlowRateDuringHeatingOperationAutosized () const |
boost::optional< double > | outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Outdoor Air Flow Rate". More... | |
bool | isOutdoorAirFlowRateWhenNoCoolingorHeatingisNeededAutosized () const |
HVACComponent | supplyAirFan () const |
HVACComponent | heatingCoil () const |
HVACComponent | coolingCoil () const |
double | maximumCyclingRate () const |
bool | isMaximumCyclingRateDefaulted () const |
double | heatPumpTimeConstant () const |
bool | isHeatPumpTimeConstantDefaulted () const |
double | fractionofOnCyclePowerUse () const |
bool | isFractionofOnCyclePowerUseDefaulted () const |
double | heatPumpFanDelayTime () const |
bool | isHeatPumpFanDelayTimeDefaulted () const |
HVACComponent | supplementalHeatingCoil () const |
boost::optional< double > | maximumSupplyAirTemperaturefromSupplementalHeater () const |
bool | isMaximumSupplyAirTemperaturefromSupplementalHeaterAutosized () const |
double | maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation () const |
bool | isMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperationDefaulted () const |
std::string | fanPlacement () const |
bool | isFanPlacementDefaulted () const |
std::string | heatPumpCoilWaterFlowMode () const |
bool | isHeatPumpCoilWaterFlowModeDefaulted () const |
boost::optional< Schedule > | supplyAirFanOperatingModeSchedule () const |
Setters | |
bool | setAvailabilitySchedule (Schedule &schedule) |
bool | setSupplyAirFlowRateDuringCoolingOperation (boost::optional< double > supplyAirFlowRateDuringCoolingOperation) |
bool | setSupplyAirFlowRateDuringCoolingOperation (double supplyAirFlowRateDuringCoolingOperation) |
void | resetSupplyAirFlowRateDuringCoolingOperation () |
void | autosizeSupplyAirFlowRateDuringCoolingOperation () |
bool | setSupplyAirFlowRateDuringHeatingOperation (boost::optional< double > supplyAirFlowRateDuringHeatingOperation) |
bool | setSupplyAirFlowRateDuringHeatingOperation (double supplyAirFlowRateDuringHeatingOperation) |
void | resetSupplyAirFlowRateDuringHeatingOperation () |
void | autosizeSupplyAirFlowRateDuringHeatingOperation () |
bool | setSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded (boost::optional< double > supplyAirFlowRateWhenNoCoolingorHeatingisNeeded) |
bool | setSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded (double supplyAirFlowRateWhenNoCoolingorHeatingisNeeded) |
void | resetSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded () |
void | autosizeSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded () |
bool | setOutdoorAirFlowRateDuringCoolingOperation (boost::optional< double > outdoorAirFlowRateDuringCoolingOperation) |
bool | setOutdoorAirFlowRateDuringCoolingOperation (double outdoorAirFlowRateDuringCoolingOperation) |
void | resetOutdoorAirFlowRateDuringCoolingOperation () |
void | autosizeOutdoorAirFlowRateDuringCoolingOperation () |
bool | setOutdoorAirFlowRateDuringHeatingOperation (boost::optional< double > outdoorAirFlowRateDuringHeatingOperation) |
bool | setOutdoorAirFlowRateDuringHeatingOperation (double outdoorAirFlowRateDuringHeatingOperation) |
void | resetOutdoorAirFlowRateDuringHeatingOperation () |
void | autosizeOutdoorAirFlowRateDuringHeatingOperation () |
bool | setOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded (boost::optional< double > outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded) |
bool | setOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded (double outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded) |
void | resetOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () |
void | autosizeOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () |
bool | setSupplyAirFan (HVACComponent &fansOnOff) |
bool | setHeatingCoil (HVACComponent &heatingCoils) |
bool | setCoolingCoil (HVACComponent &coolingCoils) |
bool | setMaximumCyclingRate (boost::optional< double > maximumCyclingRate) |
bool | setMaximumCyclingRate (double maximumCyclingRate) |
void | resetMaximumCyclingRate () |
bool | setHeatPumpTimeConstant (boost::optional< double > heatPumpTimeConstant) |
bool | setHeatPumpTimeConstant (double heatPumpTimeConstant) |
void | resetHeatPumpTimeConstant () |
bool | setFractionofOnCyclePowerUse (boost::optional< double > fractionofOnCyclePowerUse) |
bool | setFractionofOnCyclePowerUse (double fractionofOnCyclePowerUse) |
void | resetFractionofOnCyclePowerUse () |
bool | setHeatPumpFanDelayTime (boost::optional< double > heatPumpFanDelayTime) |
bool | setHeatPumpFanDelayTime (double heatPumpFanDelayTime) |
void | resetHeatPumpFanDelayTime () |
bool | setSupplementalHeatingCoil (HVACComponent &heatingCoilName) |
bool | setMaximumSupplyAirTemperaturefromSupplementalHeater (boost::optional< double > maximumSupplyAirTemperaturefromSupplementalHeater) |
bool | setMaximumSupplyAirTemperaturefromSupplementalHeater (double maximumSupplyAirTemperaturefromSupplementalHeater) |
void | resetMaximumSupplyAirTemperaturefromSupplementalHeater () |
void | autosizeMaximumSupplyAirTemperaturefromSupplementalHeater () |
bool | setMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation (boost::optional< double > maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation) |
bool | setMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation (double maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation) |
void | resetMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation () |
bool | setFanPlacement (std::string fanPlacement) |
void | resetFanPlacement () |
bool | setHeatPumpCoilWaterFlowMode (std::string heatPumpCoilWaterFlowMode) |
void | resetHeatPumpCoilWaterFlowMode () |
bool | setSupplyAirFanOperatingModeSchedule (Schedule &schedule) |
void | resetSupplyAirFanOperatingModeSchedule () |
Other | |
boost::optional< double > | autosizedSupplyAirFlowRateDuringCoolingOperation () const |
boost::optional< double > | autosizedSupplyAirFlowRateDuringHeatingOperation () const |
boost::optional< double > | autosizedSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
boost::optional< double > | autosizedOutdoorAirFlowRateDuringCoolingOperation () const |
boost::optional< double > | autosizedOutdoorAirFlowRateDuringHeatingOperation () const |
boost::optional< double > | autosizedOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
boost::optional< double > | autosizedMaximumSupplyAirTemperaturefromSupplementalHeater () const |
Public Member Functions inherited from openstudio::model::ZoneHVACComponent | |
bool | addToNode (Node &node) |
Adds this ZoneHVACComponent to a node on an AirLoopHVAC object. More... | |
bool | addToThermalZone (ThermalZone &thermalZone) |
Adds this ZoneHVACComponent to the thermal zone while managing all node connections automatically. More... | |
boost::optional< ModelObject > | airInletModelObject () const |
Provided for backwards compatibility, use inletNode instead. More... | |
boost::optional< AirLoopHVAC > | airLoopHVAC () const |
Returns the AirLoopHVAC attached to this ZoneHVACComponent. More... | |
boost::optional< ModelObject > | airOutletModelObject () const |
Provided for backwards compatibility, use outletNode instead. More... | |
boost::optional< Node > | inletNode () const |
Returns the optional node connected to the inletPort(). More... | |
unsigned | inletPort () const |
Returns the inlet port. More... | |
boost::optional< Node > | outletNode () const |
Returns the optional node connected to the outletPort(). More... | |
unsigned | outletPort () const |
Returns the outlet port. More... | |
bool | removeFromAirLoopHVAC () |
If this ZoneHVACComponent is used as a supply component on an AirLoopHVAC system, then this method will detach this ZoneHVACComponent from the AirLoopHVAC system, otherwise this method does nothing. More... | |
void | removeFromThermalZone () |
Detaches this ZoneHVACComponent from the associated ThermalZone. More... | |
void | removeReturnPlenum () |
Remove any return plenum attached to this ZoneHVACComponent. More... | |
boost::optional < AirLoopHVACReturnPlenum > | returnPlenum () const |
bool | setReturnPlenum (const ThermalZone &plenumZone) |
Establish plenumZone as the return plenum for this ZoneHVACComponent. More... | |
virtual boost::optional < ThermalZone > | thermalZone () const |
Returns the optional ThermalZone that this ZoneHVACComponent is attached to. More... | |
virtual | ~ZoneHVACComponent () |
Public Member Functions inherited from openstudio::model::HVACComponent | |
bool | addToNode (Node &node) |
Adds this object to a new system node and returns a boolean indicating if the addition was successful. More... | |
bool | addToSplitter (Splitter &splitter) |
Adds this object to a splitter by creating a new branch. More... | |
boost::optional< AirLoopHVAC > | airLoopHVAC () const |
Returns the optional AirLoopHVAC object that the HVAC component is attached to. More... | |
boost::optional < AirLoopHVACOutdoorAirSystem > | airLoopHVACOutdoorAirSystem () const |
Returns the optional AirLoopHVACOutdoorAirSystem that the HVAC component is attached to. More... | |
void | applySizingValues () |
void | autosize () |
Returns the optional ModelObject connected to this object's port. More... | |
boost::optional< HVACComponent > | containingHVACComponent () const |
EnergyPlus unitary equipment and air terminals are typically composed of other HVAC components. More... | |
boost::optional < StraightComponent > | containingStraightComponent () const |
boost::optional < ZoneHVACComponent > | containingZoneHVACComponent () const |
Returns any ZoneHVACComponent that contains this HVACComponent. More... | |
void | disconnect () |
Removes all connections to other HVACComponent objects. More... | |
bool | isRemovable () const |
Indicates if the HVACComponent can be removed from the model. More... | |
boost::optional< Loop > | loop () const |
Returns the optional Loop object that the HVAC component is attached to. More... | |
boost::optional< PlantLoop > | plantLoop () const |
Returns the optional PlantLoop object that the HVAC component is attached to. More... | |
std::vector< IdfObject > | remove () |
Removes the HVACComponent from the model only if isRemovable() return true. More... | |
virtual | ~HVACComponent () |
Public Member Functions inherited from openstudio::model::ParentObject | |
std::vector< IddObjectType > | allowableChildTypes () const |
Returns a vector of allowable children types. More... | |
std::vector< ModelObject > | children () const |
Return direct child objects in the Model. More... | |
virtual | ~ParentObject () |
Public Member Functions inherited from openstudio::model::ModelObject | |
virtual | ~ModelObject () |
ModelObject | clone () const |
Creates a deep copy of this object, placing it in this object's model(). More... | |
ModelObject | clone (Model model) const |
Creates a deep copy of this object, placing it in model. More... | |
Component | createComponent () const |
Method for creating sharable Model snippets. More... | |
Model | model () const |
Returns the Model that contains this object. More... | |
boost::optional< ParentObject > | parent () const |
Return this object's parent in the hierarchy, if it has one. More... | |
std::vector< ResourceObject > | resources () const |
Get the resources directly used by this ModelObject. More... | |
template<typename T > | |
std::vector< T > | getModelObjectSources () const |
Get all objects of type T that point to this object. More... | |
template<typename T > | |
std::vector< T > | getModelObjectSources (IddObjectType iddObjectType) const |
Get all objects of type T that point to this object. More... | |
template<typename T > | |
boost::optional< T > | getModelObjectTarget (unsigned index) const |
Get the object of type T pointed to by this object from field index. More... | |
template<typename T > | |
std::vector< T > | getModelObjectTargets () const |
Get all objects of type T to which this object points. More... | |
const std::vector< std::string > & | outputVariableNames () const |
Get all output variables names that could be associated with this object. More... | |
std::vector< OutputVariable > | outputVariables () const |
Get all output variables associated with this object, must run simulation to generate data. More... | |
boost::optional < openstudio::TimeSeries > | getData (const OutputVariable &variable, const std::string &envPeriod) const |
Get data associated with this output variable and this object. More... | |
std::vector< LifeCycleCost > | lifeCycleCosts () const |
Returns the list of all LifeCycleCosts that refer to this object. More... | |
std::vector< IdfObject > | removeLifeCycleCosts () |
Removes all LifeCycleCosts that refer to this object. More... | |
IddObjectType | iddObjectType () const |
This is a virtual function that will tell you the type of iddObject you are dealing with. More... | |
AdditionalProperties | additionalProperties () const |
Returns this object's additional properties, constructing a new object if necessary. More... | |
bool | hasAdditionalProperties () const |
Returns true if this object has additional properties. More... | |
std::vector< IdfObject > | removeAdditionalProperties () |
Removes all additional properties that refer to this object. More... | |
bool | setParent (ParentObject &newParent) |
set the parent, child may have to call non-const methods on the parent More... | |
bool | operator< (const ModelObject &right) const |
bool | operator== (const ModelObject &other) const |
equality test More... | |
bool | operator!= (const ModelObject &other) const |
inequality test More... | |
std::vector< ScheduleTypeKey > | getScheduleTypeKeys (const Schedule &schedule) const |
Return the ScheduleTypeKeys indicating how schedule is used in this object. More... | |
boost::optional< double > | getAutosizedValue (std::string valueName, std::string unitString) const |
Gets the autosized component value from the sql file. More... | |
virtual std::vector < EMSActuatorNames > | emsActuatorNames () const |
Return the names of the available ems actuators. More... | |
virtual std::vector< std::string > | emsInternalVariableNames () const |
Return the names of the available ems internal variables. More... | |
boost::optional< ModelObject > | connectedObject (unsigned port) const |
boost::optional< unsigned > | connectedObjectPort (unsigned port) const |
Static Public Member Functions | |
static std::vector< std::string > | fanPlacementValues () |
static std::vector< std::string > | heatPumpCoilWaterFlowModeValues () |
static IddObjectType | iddObjectType () |
Related Functions | |
(Note that these are not member functions.) | |
typedef boost::optional < ZoneHVACWaterToAirHeatPump > | OptionalZoneHVACWaterToAirHeatPump |
typedef std::vector < ZoneHVACWaterToAirHeatPump > | ZoneHVACWaterToAirHeatPumpVector |
Related Functions inherited from openstudio::model::ParentObject | |
std::vector< ModelObject > | getRecursiveChildren (const ParentObject &object, bool includeLifeCycleCostsAndAdditionalProperties=false) |
Returns object and all other objects accessible by calling children() on encountered ParentObjects . More... | |
std::vector< ModelObject > | getRecursiveChildrenAndResources (const ModelObject &object) |
Returns object and all other objects accessible by calling children() and resources() on encountered ModelObjects . More... | |
Related Functions inherited from openstudio::model::ModelObject | |
std::vector< ResourceObject > | getRecursiveResources (const ModelObject &object) |
Returns all ResourceObjects accessible by recursively calling .resources() starting from object. More... | |
typedef std::pair< std::string, std::string > | ScheduleTypeKey |
Typedef for ScheduleTypeRegistry key. More... | |
typedef std::pair< std::string, std::string > | ScheduleTypeKey |
Typedef for ScheduleTypeRegistry key. More... | |
Additional Inherited Members | |
Protected Types inherited from openstudio::model::ZoneHVACComponent | |
typedef detail::ZoneHVACComponent_Impl | ImplType |
Protected Types inherited from openstudio::model::HVACComponent | |
typedef detail::HVACComponent_Impl | ImplType |
Protected Types inherited from openstudio::model::ModelObject | |
typedef detail::ModelObject_Impl | ImplType |
Protected Member Functions inherited from openstudio::model::ZoneHVACComponent | |
virtual std::vector< ModelObject > | children () const override |
ZoneHVACComponent (IddObjectType type, const Model &model) | |
ZoneHVACComponent (std::shared_ptr< ImplType > impl) | |
Protected Member Functions inherited from openstudio::model::HVACComponent | |
HVACComponent (IddObjectType type, const Model &model) | |
HVACComponent (std::shared_ptr< ImplType > impl) | |
Protected Member Functions inherited from openstudio::model::ParentObject | |
ParentObject (IddObjectType type, const Model &model) | |
Constructs a new ParentObject object in the model. More... | |
Protected Member Functions inherited from openstudio::model::ModelObject | |
ModelObject (IddObjectType type, const Model &model, bool fastName=false) | |
ModelObject (std::shared_ptr< detail::ModelObject_Impl > impl) | |
ZoneHVACWaterToAirHeatPump is a ZoneHVACComponent that wraps the OpenStudio IDD object 'OS:ZoneHVAC:WaterToAirHeatPump'.
openstudio::model::ZoneHVACWaterToAirHeatPump::ZoneHVACWaterToAirHeatPump | ( | const Model & | model, |
Schedule & | availabilitySchedule, | ||
HVACComponent & | supplyAirFan, | ||
HVACComponent & | heatingCoil, | ||
HVACComponent & | coolingCoil, | ||
HVACComponent & | supplementalHeatingCoil | ||
) |
|
inlinevirtual |
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::autosizedMaximumSupplyAirTemperaturefromSupplementalHeater | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::autosizedOutdoorAirFlowRateDuringCoolingOperation | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::autosizedOutdoorAirFlowRateDuringHeatingOperation | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::autosizedOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::autosizedSupplyAirFlowRateDuringCoolingOperation | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::autosizedSupplyAirFlowRateDuringHeatingOperation | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::autosizedSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
void openstudio::model::ZoneHVACWaterToAirHeatPump::autosizeMaximumSupplyAirTemperaturefromSupplementalHeater | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::autosizeOutdoorAirFlowRateDuringCoolingOperation | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::autosizeOutdoorAirFlowRateDuringHeatingOperation | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::autosizeOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::autosizeSupplyAirFlowRateDuringCoolingOperation | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::autosizeSupplyAirFlowRateDuringHeatingOperation | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::autosizeSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) |
Schedule openstudio::model::ZoneHVACWaterToAirHeatPump::availabilitySchedule | ( | ) | const |
HVACComponent openstudio::model::ZoneHVACWaterToAirHeatPump::coolingCoil | ( | ) | const |
std::string openstudio::model::ZoneHVACWaterToAirHeatPump::fanPlacement | ( | ) | const |
|
static |
double openstudio::model::ZoneHVACWaterToAirHeatPump::fractionofOnCyclePowerUse | ( | ) | const |
HVACComponent openstudio::model::ZoneHVACWaterToAirHeatPump::heatingCoil | ( | ) | const |
std::string openstudio::model::ZoneHVACWaterToAirHeatPump::heatPumpCoilWaterFlowMode | ( | ) | const |
|
static |
double openstudio::model::ZoneHVACWaterToAirHeatPump::heatPumpFanDelayTime | ( | ) | const |
double openstudio::model::ZoneHVACWaterToAirHeatPump::heatPumpTimeConstant | ( | ) | const |
|
static |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isFanPlacementDefaulted | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isFractionofOnCyclePowerUseDefaulted | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isHeatPumpCoilWaterFlowModeDefaulted | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isHeatPumpFanDelayTimeDefaulted | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isHeatPumpTimeConstantDefaulted | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isMaximumCyclingRateDefaulted | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperationDefaulted | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isMaximumSupplyAirTemperaturefromSupplementalHeaterAutosized | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isOutdoorAirFlowRateDuringCoolingOperationAutosized | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isOutdoorAirFlowRateDuringHeatingOperationAutosized | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isOutdoorAirFlowRateWhenNoCoolingorHeatingisNeededAutosized | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isSupplyAirFlowRateDuringCoolingOperationAutosized | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isSupplyAirFlowRateDuringHeatingOperationAutosized | ( | ) | const |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::isSupplyAirFlowRateWhenNoCoolingorHeatingisNeededAutosized | ( | ) | const |
double openstudio::model::ZoneHVACWaterToAirHeatPump::maximumCyclingRate | ( | ) | const |
double openstudio::model::ZoneHVACWaterToAirHeatPump::maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::maximumSupplyAirTemperaturefromSupplementalHeater | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::outdoorAirFlowRateDuringCoolingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Outdoor Air Flow Rate".
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::outdoorAirFlowRateDuringHeatingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Outdoor Air Flow Rate".
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Outdoor Air Flow Rate".
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetFanPlacement | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetFractionofOnCyclePowerUse | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetHeatPumpCoilWaterFlowMode | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetHeatPumpFanDelayTime | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetHeatPumpTimeConstant | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetMaximumCyclingRate | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetMaximumSupplyAirTemperaturefromSupplementalHeater | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetOutdoorAirFlowRateDuringCoolingOperation | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetOutdoorAirFlowRateDuringHeatingOperation | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetSupplyAirFanOperatingModeSchedule | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetSupplyAirFlowRateDuringCoolingOperation | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetSupplyAirFlowRateDuringHeatingOperation | ( | ) |
void openstudio::model::ZoneHVACWaterToAirHeatPump::resetSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setAvailabilitySchedule | ( | Schedule & | schedule | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setCoolingCoil | ( | HVACComponent & | coolingCoils | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setFanPlacement | ( | std::string | fanPlacement | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setFractionofOnCyclePowerUse | ( | boost::optional< double > | fractionofOnCyclePowerUse | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setFractionofOnCyclePowerUse | ( | double | fractionofOnCyclePowerUse | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setHeatingCoil | ( | HVACComponent & | heatingCoils | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setHeatPumpCoilWaterFlowMode | ( | std::string | heatPumpCoilWaterFlowMode | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setHeatPumpFanDelayTime | ( | boost::optional< double > | heatPumpFanDelayTime | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setHeatPumpFanDelayTime | ( | double | heatPumpFanDelayTime | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setHeatPumpTimeConstant | ( | boost::optional< double > | heatPumpTimeConstant | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setHeatPumpTimeConstant | ( | double | heatPumpTimeConstant | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setMaximumCyclingRate | ( | boost::optional< double > | maximumCyclingRate | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setMaximumCyclingRate | ( | double | maximumCyclingRate | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ( | boost::optional< double > | maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ( | double | maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setMaximumSupplyAirTemperaturefromSupplementalHeater | ( | boost::optional< double > | maximumSupplyAirTemperaturefromSupplementalHeater | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setMaximumSupplyAirTemperaturefromSupplementalHeater | ( | double | maximumSupplyAirTemperaturefromSupplementalHeater | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setOutdoorAirFlowRateDuringCoolingOperation | ( | boost::optional< double > | outdoorAirFlowRateDuringCoolingOperation | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setOutdoorAirFlowRateDuringCoolingOperation | ( | double | outdoorAirFlowRateDuringCoolingOperation | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setOutdoorAirFlowRateDuringHeatingOperation | ( | boost::optional< double > | outdoorAirFlowRateDuringHeatingOperation | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setOutdoorAirFlowRateDuringHeatingOperation | ( | double | outdoorAirFlowRateDuringHeatingOperation | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | boost::optional< double > | outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | double | outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setSupplementalHeatingCoil | ( | HVACComponent & | heatingCoilName | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setSupplyAirFan | ( | HVACComponent & | fansOnOff | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setSupplyAirFanOperatingModeSchedule | ( | Schedule & | schedule | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setSupplyAirFlowRateDuringCoolingOperation | ( | boost::optional< double > | supplyAirFlowRateDuringCoolingOperation | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setSupplyAirFlowRateDuringCoolingOperation | ( | double | supplyAirFlowRateDuringCoolingOperation | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setSupplyAirFlowRateDuringHeatingOperation | ( | boost::optional< double > | supplyAirFlowRateDuringHeatingOperation | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setSupplyAirFlowRateDuringHeatingOperation | ( | double | supplyAirFlowRateDuringHeatingOperation | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | boost::optional< double > | supplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ) |
bool openstudio::model::ZoneHVACWaterToAirHeatPump::setSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | double | supplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ) |
HVACComponent openstudio::model::ZoneHVACWaterToAirHeatPump::supplementalHeatingCoil | ( | ) | const |
HVACComponent openstudio::model::ZoneHVACWaterToAirHeatPump::supplyAirFan | ( | ) | const |
boost::optional<Schedule> openstudio::model::ZoneHVACWaterToAirHeatPump::supplyAirFanOperatingModeSchedule | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::supplyAirFlowRateDuringCoolingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Supply Air Flow Rate".
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::supplyAirFlowRateDuringHeatingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Supply Air Flow Rate".
boost::optional<double> openstudio::model::ZoneHVACWaterToAirHeatPump::supplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Supply Air Flow Rate".
|
related |
|
related |