#include <AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass.hpp>
Public Member Functions | |
Constructors and Destructors | |
AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass (const Model &model, const HVACComponent &fan, const HVACComponent &coolingCoil, const HVACComponent &heatingCoil) | |
virtual | ~AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass () |
Getters | |
boost::optional< Schedule > | availabilitySchedule () const |
boost::optional< double > | systemAirFlowRateDuringCoolingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Supply Air Flow Rate". More... | |
bool | isSystemAirFlowRateDuringCoolingOperationAutosized () const |
boost::optional< double > | systemAirFlowRateDuringHeatingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Supply Air Flow Rate". More... | |
bool | isSystemAirFlowRateDuringHeatingOperationAutosized () const |
boost::optional< double > | systemAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Supply Air Flow Rate". More... | |
bool | isSystemAirFlowRateWhenNoCoolingorHeatingisNeededAutosized () const |
boost::optional< double > | outdoorAirFlowRateDuringCoolingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Outdoor Air Flow Rate". More... | |
bool | isOutdoorAirFlowRateDuringCoolingOperationAutosized () const |
boost::optional< double > | outdoorAirFlowRateDuringHeatingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Outdoor Air Flow Rate". More... | |
bool | isOutdoorAirFlowRateDuringHeatingOperationAutosized () const |
boost::optional< double > | outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Outdoor Air Flow Rate". More... | |
bool | isOutdoorAirFlowRateWhenNoCoolingorHeatingisNeededAutosized () const |
boost::optional< Schedule > | outdoorAirFlowRateMultiplierSchedule () const |
HVACComponent | supplyAirFan () const |
std::string | supplyAirFanPlacement () const |
boost::optional< Schedule > | supplyAirFanOperatingModeSchedule () const |
HVACComponent | coolingCoil () const |
HVACComponent | heatingCoil () const |
std::string | priorityControlMode () const |
double | minimumOutletAirTemperatureDuringCoolingOperation () const |
double | maximumOutletAirTemperatureDuringHeatingOperation () const |
std::string | dehumidificationControlType () const |
double | minimumRuntimeBeforeOperatingModeChange () const |
unsigned | plenumorMixerAirPort () const |
Node | plenumorMixerNode () const |
This Node always exists for connecting "Plenum or Mixer Inlet Node", it will be translated only if actually connected to an AirLoopHVAC:ReturnPlenum or an AirLoopHVAC:ZoneMixer. More... | |
boost::optional< Mixer > | plenumorMixer () const |
Convenience method to get the optional linked Mixer object (AirLoopHVAC:ReturnPlenum or AirLoopHVAC:ZoneMixer) More... | |
Setters | |
bool | setAvailabilitySchedule (Schedule &schedule) |
void | resetAvailabilitySchedule () |
bool | setSystemAirFlowRateDuringCoolingOperation (double systemAirFlowRateDuringCoolingOperation) |
void | autosizeSystemAirFlowRateDuringCoolingOperation () |
bool | setSystemAirFlowRateDuringHeatingOperation (double systemAirFlowRateDuringHeatingOperation) |
void | autosizeSystemAirFlowRateDuringHeatingOperation () |
bool | setSystemAirFlowRateWhenNoCoolingorHeatingisNeeded (double systemAirFlowRateWhenNoCoolingorHeatingisNeeded) |
void | autosizeSystemAirFlowRateWhenNoCoolingorHeatingisNeeded () |
bool | setOutdoorAirFlowRateDuringCoolingOperation (double outdoorAirFlowRateDuringCoolingOperation) |
void | autosizeOutdoorAirFlowRateDuringCoolingOperation () |
bool | setOutdoorAirFlowRateDuringHeatingOperation (double outdoorAirFlowRateDuringHeatingOperation) |
void | autosizeOutdoorAirFlowRateDuringHeatingOperation () |
bool | setOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded (double outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded) |
void | autosizeOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () |
bool | setOutdoorAirFlowRateMultiplierSchedule (Schedule &outdoorAirFlowRateMultiplierSchedule) |
void | resetOutdoorAirFlowRateMultiplierSchedule () |
bool | setSupplyAirFan (const HVACComponent &fansCVandOnOff) |
bool | setSupplyAirFanPlacement (std::string supplyAirFanPlacement) |
bool | setSupplyAirFanOperatingModeSchedule (Schedule &schedule) |
void | resetSupplyAirFanOperatingModeSchedule () |
bool | setCoolingCoil (const HVACComponent &coolingCoilsDXMultiModeOrSingleSpeed) |
bool | setHeatingCoil (const HVACComponent &heatingCoilName) |
bool | setPriorityControlMode (std::string priorityControlMode) |
bool | setMinimumOutletAirTemperatureDuringCoolingOperation (double minimumOutletAirTemperatureDuringCoolingOperation) |
bool | setMaximumOutletAirTemperatureDuringHeatingOperation (double maximumOutletAirTemperatureDuringHeatingOperation) |
bool | setDehumidificationControlType (std::string dehumidificationControlType) |
bool | setMinimumRuntimeBeforeOperatingModeChange (double runtime) |
bool | setPlenumorMixer (const Mixer &returnPathComponent) |
Connect the bypass air duct to an AirLoopHVAC:ReturnPlenum or an AirLoopHVAC:ZoneMixer that must be on the same AirLoopHVAC as this Unitary System. More... | |
void | resetPlenumorMixer () |
boost::optional< double > | autosizedSystemAirFlowRateDuringCoolingOperation () const |
boost::optional< double > | autosizedSystemAirFlowRateDuringHeatingOperation () const |
boost::optional< double > | autosizedSystemAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
boost::optional< double > | autosizedOutdoorAirFlowRateDuringCoolingOperation () const |
boost::optional< double > | autosizedOutdoorAirFlowRateDuringHeatingOperation () const |
boost::optional< double > | autosizedOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
Public Member Functions inherited from openstudio::model::StraightComponent | |
bool | addToNode (Node &node) |
boost::optional< AirLoopHVAC > | airLoopHVAC () const |
Returns the optional AirLoopHVAC object that this AirToAirComponent is attached to. More... | |
ModelObject | clone (Model model) const |
void | disconnect () |
boost::optional< ModelObject > | inletModelObject () const |
Returns the optional ModelObject connected to the inlet port. More... | |
unsigned | inletPort () const |
Returns the inlet port. More... | |
boost::optional< ModelObject > | outletModelObject () const |
Returns the optional ModelObject connected to the outlet port. More... | |
unsigned | outletPort () const |
Returns the outlet port. More... | |
std::vector < openstudio::IdfObject > | remove () |
bool | removeFromLoop () |
StraightComponent (IddObjectType type, const Model &model) | |
virtual | ~StraightComponent () |
Public Member Functions inherited from openstudio::model::HVACComponent | |
bool | addToNode (Node &node) |
Adds this object to a new system node and returns a boolean indicating if the addition was successful. More... | |
bool | addToSplitter (Splitter &splitter) |
Adds this object to a splitter by creating a new branch. More... | |
boost::optional< AirLoopHVAC > | airLoopHVAC () const |
Returns the optional AirLoopHVAC object that the HVAC component is attached to. More... | |
boost::optional < AirLoopHVACOutdoorAirSystem > | airLoopHVACOutdoorAirSystem () const |
Returns the optional AirLoopHVACOutdoorAirSystem that the HVAC component is attached to. More... | |
void | applySizingValues () |
void | autosize () |
Returns the optional ModelObject connected to this object's port. More... | |
boost::optional< HVACComponent > | containingHVACComponent () const |
EnergyPlus unitary equipment and air terminals are typically composed of other HVAC components. More... | |
boost::optional < StraightComponent > | containingStraightComponent () const |
boost::optional < ZoneHVACComponent > | containingZoneHVACComponent () const |
Returns any ZoneHVACComponent that contains this HVACComponent. More... | |
void | disconnect () |
Removes all connections to other HVACComponent objects. More... | |
bool | isRemovable () const |
Indicates if the HVACComponent can be removed from the model. More... | |
boost::optional< Loop > | loop () const |
Returns the optional Loop object that the HVAC component is attached to. More... | |
boost::optional< PlantLoop > | plantLoop () const |
Returns the optional PlantLoop object that the HVAC component is attached to. More... | |
std::vector< IdfObject > | remove () |
Removes the HVACComponent from the model only if isRemovable() return true. More... | |
virtual | ~HVACComponent () |
Public Member Functions inherited from openstudio::model::ParentObject | |
std::vector< IddObjectType > | allowableChildTypes () const |
Returns a vector of allowable children types. More... | |
std::vector< ModelObject > | children () const |
Return direct child objects in the Model. More... | |
virtual | ~ParentObject () |
Public Member Functions inherited from openstudio::model::ModelObject | |
virtual | ~ModelObject () |
ModelObject | clone () const |
Creates a deep copy of this object, placing it in this object's model(). More... | |
ModelObject | clone (Model model) const |
Creates a deep copy of this object, placing it in model. More... | |
Component | createComponent () const |
Method for creating sharable Model snippets. More... | |
Model | model () const |
Returns the Model that contains this object. More... | |
boost::optional< ParentObject > | parent () const |
Return this object's parent in the hierarchy, if it has one. More... | |
std::vector< ResourceObject > | resources () const |
Get the resources directly used by this ModelObject. More... | |
template<typename T > | |
std::vector< T > | getModelObjectSources () const |
Get all objects of type T that point to this object. More... | |
template<typename T > | |
std::vector< T > | getModelObjectSources (IddObjectType iddObjectType) const |
Get all objects of type T that point to this object. More... | |
template<typename T > | |
boost::optional< T > | getModelObjectTarget (unsigned index) const |
Get the object of type T pointed to by this object from field index. More... | |
template<typename T > | |
std::vector< T > | getModelObjectTargets () const |
Get all objects of type T to which this object points. More... | |
const std::vector< std::string > & | outputVariableNames () const |
Get all output variables names that could be associated with this object. More... | |
std::vector< OutputVariable > | outputVariables () const |
Get all output variables associated with this object, must run simulation to generate data. More... | |
boost::optional < openstudio::TimeSeries > | getData (const OutputVariable &variable, const std::string &envPeriod) const |
Get data associated with this output variable and this object. More... | |
std::vector< LifeCycleCost > | lifeCycleCosts () const |
Returns the list of all LifeCycleCosts that refer to this object. More... | |
std::vector< IdfObject > | removeLifeCycleCosts () |
Removes all LifeCycleCosts that refer to this object. More... | |
IddObjectType | iddObjectType () const |
This is a virtual function that will tell you the type of iddObject you are dealing with. More... | |
AdditionalProperties | additionalProperties () const |
Returns this object's additional properties, constructing a new object if necessary. More... | |
bool | hasAdditionalProperties () const |
Returns true if this object has additional properties. More... | |
std::vector< IdfObject > | removeAdditionalProperties () |
Removes all additional properties that refer to this object. More... | |
bool | setParent (ParentObject &newParent) |
set the parent, child may have to call non-const methods on the parent More... | |
bool | operator< (const ModelObject &right) const |
bool | operator== (const ModelObject &other) const |
equality test More... | |
bool | operator!= (const ModelObject &other) const |
inequality test More... | |
std::vector< ScheduleTypeKey > | getScheduleTypeKeys (const Schedule &schedule) const |
Return the ScheduleTypeKeys indicating how schedule is used in this object. More... | |
boost::optional< double > | getAutosizedValue (std::string valueName, std::string unitString) const |
Gets the autosized component value from the sql file. More... | |
virtual std::vector < EMSActuatorNames > | emsActuatorNames () const |
Return the names of the available ems actuators. More... | |
virtual std::vector< std::string > | emsInternalVariableNames () const |
Return the names of the available ems internal variables. More... | |
boost::optional< ModelObject > | connectedObject (unsigned port) const |
boost::optional< unsigned > | connectedObjectPort (unsigned port) const |
Static Public Member Functions | |
static std::vector< std::string > | dehumidificationControlTypeValues () |
static IddObjectType | iddObjectType () |
static std::vector< std::string > | priorityControlModeValues () |
static std::vector< std::string > | supplyAirFanPlacementValues () |
Related Functions | |
(Note that these are not member functions.) | |
typedef std::vector < AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass > | AirLoopHVACUnitaryHeatCoolVAVChangeoverBypassVector |
typedef boost::optional < AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass > | OptionalAirLoopHVACUnitaryHeatCoolVAVChangeoverBypass |
Related Functions inherited from openstudio::model::ParentObject | |
std::vector< ModelObject > | getRecursiveChildren (const ParentObject &object, bool includeLifeCycleCostsAndAdditionalProperties=false, bool includeUsedResources=true) |
Returns object and all other objects accessible by calling children() on encountered ParentObjects . More... | |
std::vector< ModelObject > | getRecursiveChildrenAndResources (const ModelObject &object) |
Returns object and all other objects accessible by calling children() and resources() on encountered ModelObjects . More... | |
Related Functions inherited from openstudio::model::ModelObject | |
std::vector< ResourceObject > | getRecursiveResources (const ModelObject &object) |
Returns all ResourceObjects accessible by recursively calling .resources() starting from object. More... | |
Additional Inherited Members | |
Protected Types inherited from openstudio::model::HVACComponent | |
typedef detail::HVACComponent_Impl | ImplType |
Protected Types inherited from openstudio::model::ModelObject | |
typedef detail::ModelObject_Impl | ImplType |
Protected Member Functions inherited from openstudio::model::HVACComponent | |
virtual std::vector< ModelObject > | children () const |
HVACComponent (IddObjectType type, const Model &model) | |
HVACComponent (std::shared_ptr< ImplType > impl) | |
Protected Member Functions inherited from openstudio::model::ParentObject | |
ParentObject (IddObjectType type, const Model &model) | |
Constructs a new ParentObject object in the model. More... | |
Protected Member Functions inherited from openstudio::model::ModelObject | |
ModelObject (IddObjectType type, const Model &model, bool fastName=false) | |
ModelObject (std::shared_ptr< detail::ModelObject_Impl > impl) | |
AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass is a StraightComponent that wraps the OpenStudio IDD object 'OS:AirLoopHVAC:UnitaryHeatCool:VAVChangeoverBypass'.
|
explicit |
|
inlinevirtual |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::autosizedOutdoorAirFlowRateDuringCoolingOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::autosizedOutdoorAirFlowRateDuringHeatingOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::autosizedOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::autosizedSystemAirFlowRateDuringCoolingOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::autosizedSystemAirFlowRateDuringHeatingOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::autosizedSystemAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
void openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::autosizeOutdoorAirFlowRateDuringCoolingOperation | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::autosizeOutdoorAirFlowRateDuringHeatingOperation | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::autosizeOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::autosizeSystemAirFlowRateDuringCoolingOperation | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::autosizeSystemAirFlowRateDuringHeatingOperation | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::autosizeSystemAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) |
boost::optional<Schedule> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::availabilitySchedule | ( | ) | const |
HVACComponent openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::coolingCoil | ( | ) | const |
std::string openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::dehumidificationControlType | ( | ) | const |
|
static |
HVACComponent openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::heatingCoil | ( | ) | const |
|
static |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::isOutdoorAirFlowRateDuringCoolingOperationAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::isOutdoorAirFlowRateDuringHeatingOperationAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::isOutdoorAirFlowRateWhenNoCoolingorHeatingisNeededAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::isSystemAirFlowRateDuringCoolingOperationAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::isSystemAirFlowRateDuringHeatingOperationAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::isSystemAirFlowRateWhenNoCoolingorHeatingisNeededAutosized | ( | ) | const |
double openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::maximumOutletAirTemperatureDuringHeatingOperation | ( | ) | const |
double openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::minimumOutletAirTemperatureDuringCoolingOperation | ( | ) | const |
double openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::minimumRuntimeBeforeOperatingModeChange | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::outdoorAirFlowRateDuringCoolingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Outdoor Air Flow Rate".
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::outdoorAirFlowRateDuringHeatingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Outdoor Air Flow Rate".
boost::optional<Schedule> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::outdoorAirFlowRateMultiplierSchedule | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Outdoor Air Flow Rate".
boost::optional<Mixer> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::plenumorMixer | ( | ) | const |
Convenience method to get the optional linked Mixer object (AirLoopHVAC:ReturnPlenum or AirLoopHVAC:ZoneMixer)
unsigned openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::plenumorMixerAirPort | ( | ) | const |
Node openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::plenumorMixerNode | ( | ) | const |
This Node always exists for connecting "Plenum or Mixer Inlet Node", it will be translated only if actually connected to an AirLoopHVAC:ReturnPlenum or an AirLoopHVAC:ZoneMixer.
std::string openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::priorityControlMode | ( | ) | const |
|
static |
void openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::resetAvailabilitySchedule | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::resetOutdoorAirFlowRateMultiplierSchedule | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::resetPlenumorMixer | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::resetSupplyAirFanOperatingModeSchedule | ( | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setAvailabilitySchedule | ( | Schedule & | schedule | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setCoolingCoil | ( | const HVACComponent & | coolingCoilsDXMultiModeOrSingleSpeed | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setDehumidificationControlType | ( | std::string | dehumidificationControlType | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setHeatingCoil | ( | const HVACComponent & | heatingCoilName | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setMaximumOutletAirTemperatureDuringHeatingOperation | ( | double | maximumOutletAirTemperatureDuringHeatingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setMinimumOutletAirTemperatureDuringCoolingOperation | ( | double | minimumOutletAirTemperatureDuringCoolingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setMinimumRuntimeBeforeOperatingModeChange | ( | double | runtime | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setOutdoorAirFlowRateDuringCoolingOperation | ( | double | outdoorAirFlowRateDuringCoolingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setOutdoorAirFlowRateDuringHeatingOperation | ( | double | outdoorAirFlowRateDuringHeatingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setOutdoorAirFlowRateMultiplierSchedule | ( | Schedule & | outdoorAirFlowRateMultiplierSchedule | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | double | outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setPlenumorMixer | ( | const Mixer & | returnPathComponent | ) |
Connect the bypass air duct to an AirLoopHVAC:ReturnPlenum or an AirLoopHVAC:ZoneMixer that must be on the same AirLoopHVAC as this Unitary System.
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setPriorityControlMode | ( | std::string | priorityControlMode | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setSupplyAirFan | ( | const HVACComponent & | fansCVandOnOff | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setSupplyAirFanOperatingModeSchedule | ( | Schedule & | schedule | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setSupplyAirFanPlacement | ( | std::string | supplyAirFanPlacement | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setSystemAirFlowRateDuringCoolingOperation | ( | double | systemAirFlowRateDuringCoolingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setSystemAirFlowRateDuringHeatingOperation | ( | double | systemAirFlowRateDuringHeatingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::setSystemAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | double | systemAirFlowRateWhenNoCoolingorHeatingisNeeded | ) |
HVACComponent openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::supplyAirFan | ( | ) | const |
boost::optional<Schedule> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::supplyAirFanOperatingModeSchedule | ( | ) | const |
std::string openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::supplyAirFanPlacement | ( | ) | const |
|
static |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::systemAirFlowRateDuringCoolingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Supply Air Flow Rate".
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::systemAirFlowRateDuringHeatingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Supply Air Flow Rate".
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass::systemAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Supply Air Flow Rate".
|
related |
|
related |