#include <HeatPumpWaterToWaterEquationFitCooling.hpp>
Public Member Functions | |
Constructors and Destructors | |
HeatPumpWaterToWaterEquationFitCooling (const Model &model) | |
virtual | ~HeatPumpWaterToWaterEquationFitCooling () |
Getters | |
boost::optional< double > | referenceLoadSideFlowRate () const |
double | ratedLoadSideFlowRate () const |
Prior to EnergyPlus 8.7.0 this field was not autosizeable. More... | |
bool | isReferenceLoadSideFlowRateAutosized () const |
boost::optional< double > | referenceSourceSideFlowRate () const |
double | ratedSourceSideFlowRate () const |
Prior to EnergyPlus 8.7.0 this field was not autosizeable. More... | |
bool | isReferenceSourceSideFlowRateAutosized () const |
boost::optional< double > | ratedCoolingCapacity () const |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Cooling Capacity". More... | |
bool | isRatedCoolingCapacityAutosized () const |
boost::optional< double > | ratedCoolingPowerConsumption () const |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Cooling Power Consumption". More... | |
bool | isRatedCoolingPowerConsumptionAutosized () const |
double | coolingCapacityCoefficient1 () const |
double | coolingCapacityCoefficient2 () const |
double | coolingCapacityCoefficient3 () const |
double | coolingCapacityCoefficient4 () const |
double | coolingCapacityCoefficient5 () const |
double | coolingCompressorPowerCoefficient1 () const |
double | coolingCompressorPowerCoefficient2 () const |
double | coolingCompressorPowerCoefficient3 () const |
double | coolingCompressorPowerCoefficient4 () const |
double | coolingCompressorPowerCoefficient5 () const |
double | referenceCoefficientofPerformance () const |
double | sizingFactor () const |
boost::optional < HeatPumpWaterToWaterEquationFitHeating > | companionHeatingHeatPump () const |
Setters | |
bool | setReferenceLoadSideFlowRate (double referenceLoadSideFlowRate) |
bool | setRatedLoadSideFlowRate (double ratedLoadSideFlowRate) |
Synonym of setReferenceLoadSideFlowRate for backwards compatibility. More... | |
void | autosizeReferenceLoadSideFlowRate () |
bool | setReferenceSourceSideFlowRate (double referenceSourceSideFlowRate) |
bool | setRatedSourceSideFlowRate (double ratedSourceSideFlowRate) |
Synonym of setReferenceLoadSideFlowRate for backwards compatibility. More... | |
void | autosizeReferenceSourceSideFlowRate () |
bool | setRatedCoolingCapacity (double ratedCoolingCapacity) |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Cooling Capacity". More... | |
void | autosizeRatedCoolingCapacity () |
bool | setRatedCoolingPowerConsumption (double ratedCoolingPowerConsumption) |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Cooling Power Consumption". More... | |
void | autosizeRatedCoolingPowerConsumption () |
bool | setCoolingCapacityCoefficient1 (double coolingCapacityCoefficient1) |
bool | setCoolingCapacityCoefficient2 (double coolingCapacityCoefficient2) |
bool | setCoolingCapacityCoefficient3 (double coolingCapacityCoefficient3) |
bool | setCoolingCapacityCoefficient4 (double coolingCapacityCoefficient4) |
bool | setCoolingCapacityCoefficient5 (double coolingCapacityCoefficient5) |
bool | setCoolingCompressorPowerCoefficient1 (double coolingCompressorPowerCoefficient1) |
bool | setCoolingCompressorPowerCoefficient2 (double coolingCompressorPowerCoefficient2) |
bool | setCoolingCompressorPowerCoefficient3 (double coolingCompressorPowerCoefficient3) |
bool | setCoolingCompressorPowerCoefficient4 (double coolingCompressorPowerCoefficient4) |
bool | setCoolingCompressorPowerCoefficient5 (double coolingCompressorPowerCoefficient5) |
bool | setReferenceCoefficientofPerformance (double referenceCoefficientofPerformance) |
bool | setSizingFactor (double sizingFactor) |
bool | setCompanionHeatingHeatPump (const HeatPumpWaterToWaterEquationFitHeating &companionHP) |
Other | |
boost::optional< double > | autosizedReferenceLoadSideFlowRate () const |
boost::optional< double > | autosizedReferenceSourceSideFlowRate () const |
boost::optional< double > | autosizedRatedCoolingCapacity () const |
boost::optional< double > | autosizedRatedCoolingPowerConsumption () const |
Public Member Functions inherited from openstudio::model::WaterToWaterComponent | |
virtual bool | addToNode (Node &node) |
virtual bool | addToTertiaryNode (Node &node) |
Add this WaterToWaterComponent to a tertiaryPlantLoop by making connections to the tertiary inlet and outlet. More... | |
virtual ModelObject | clone (Model model) const |
virtual boost::optional < ModelObject > | demandInletModelObject () const |
Returns the optional ModelObject connected to the demand inlet port. More... | |
virtual unsigned | demandInletPort () const |
Returns the demand inlet port. More... | |
virtual boost::optional < ModelObject > | demandOutletModelObject () const |
Returns the optional ModelObject connected to the demand outlet port. More... | |
virtual unsigned | demandOutletPort () const |
Returns the demand outlet port. More... | |
void | disconnect () |
boost::optional< PlantLoop > | plantLoop () const |
Returns the optional PlantLoop object that the HVAC component is a supply component on. More... | |
virtual std::vector < openstudio::IdfObject > | remove () |
bool | removeFromPlantLoop () |
Removes the component from the plantLoop if one is attached. More... | |
bool | removeFromSecondaryPlantLoop () |
Removes the component from the secondaryPlantLoop if one is attached. More... | |
bool | removeFromTertiaryPlantLoop () |
Removes the component from the tertiaryPlantLoop if one is attached. More... | |
boost::optional< PlantLoop > | secondaryPlantLoop () const |
Returns the optional PlantLoop object that the HVAC component is a demand component on. More... | |
virtual boost::optional < ModelObject > | supplyInletModelObject () const |
Returns the optional ModelObject connected to the supply inlet port. More... | |
virtual unsigned | supplyInletPort () const |
Returns the supply inlet port. More... | |
virtual boost::optional < ModelObject > | supplyOutletModelObject () const |
Returns the optional ModelObject connected to the supply outlet port. More... | |
virtual unsigned | supplyOutletPort () const |
Returns the supply outlet port. More... | |
boost::optional< ModelObject > | tertiaryInletModelObject () const |
Returns the optional ModelObject connected to the tertiary inlet. More... | |
boost::optional< ModelObject > | tertiaryOutletModelObject () const |
Returns the optional ModelObject connected to the tertiary outlet. More... | |
boost::optional< PlantLoop > | tertiaryPlantLoop () const |
Tertiary plant loop applies to a limited number of WaterToWaterComponent types that interact with three plant systems. More... | |
WaterToWaterComponent (IddObjectType type, const Model &model) | |
virtual | ~WaterToWaterComponent () |
Public Member Functions inherited from openstudio::model::HVACComponent | |
bool | addToNode (Node &node) |
Adds this object to a new system node and returns a boolean indicating if the addition was successful. More... | |
bool | addToSplitter (Splitter &splitter) |
Adds this object to a splitter by creating a new branch. More... | |
boost::optional< AirLoopHVAC > | airLoopHVAC () const |
Returns the optional AirLoopHVAC object that the HVAC component is attached to. More... | |
boost::optional < AirLoopHVACOutdoorAirSystem > | airLoopHVACOutdoorAirSystem () const |
Returns the optional AirLoopHVACOutdoorAirSystem that the HVAC component is attached to. More... | |
void | applySizingValues () |
void | autosize () |
Returns the optional ModelObject connected to this object's port. More... | |
boost::optional< HVACComponent > | containingHVACComponent () const |
EnergyPlus unitary equipment and air terminals are typically composed of other HVAC components. More... | |
boost::optional < StraightComponent > | containingStraightComponent () const |
boost::optional < ZoneHVACComponent > | containingZoneHVACComponent () const |
Returns any ZoneHVACComponent that contains this HVACComponent. More... | |
void | disconnect () |
Removes all connections to other HVACComponent objects. More... | |
bool | isRemovable () const |
Indicates if the HVACComponent can be removed from the model. More... | |
boost::optional< Loop > | loop () const |
Returns the optional Loop object that the HVAC component is attached to. More... | |
boost::optional< PlantLoop > | plantLoop () const |
Returns the optional PlantLoop object that the HVAC component is attached to. More... | |
std::vector< IdfObject > | remove () |
Removes the HVACComponent from the model only if isRemovable() return true. More... | |
virtual | ~HVACComponent () |
Public Member Functions inherited from openstudio::model::ParentObject | |
std::vector< IddObjectType > | allowableChildTypes () const |
Returns a vector of allowable children types. More... | |
std::vector< ModelObject > | children () const |
Return direct child objects in the Model. More... | |
virtual | ~ParentObject () |
Public Member Functions inherited from openstudio::model::ModelObject | |
virtual | ~ModelObject () |
ModelObject | clone () const |
Creates a deep copy of this object, placing it in this object's model(). More... | |
ModelObject | clone (Model model) const |
Creates a deep copy of this object, placing it in model. More... | |
Component | createComponent () const |
Method for creating sharable Model snippets. More... | |
Model | model () const |
Returns the Model that contains this object. More... | |
boost::optional< ParentObject > | parent () const |
Return this object's parent in the hierarchy, if it has one. More... | |
std::vector< ResourceObject > | resources () const |
Get the resources directly used by this ModelObject. More... | |
template<typename T > | |
std::vector< T > | getModelObjectSources () const |
Get all objects of type T that point to this object. More... | |
template<typename T > | |
std::vector< T > | getModelObjectSources (IddObjectType iddObjectType) const |
Get all objects of type T that point to this object. More... | |
template<typename T > | |
boost::optional< T > | getModelObjectTarget (unsigned index) const |
Get the object of type T pointed to by this object from field index. More... | |
template<typename T > | |
std::vector< T > | getModelObjectTargets () const |
Get all objects of type T to which this object points. More... | |
const std::vector< std::string > & | outputVariableNames () const |
Get all output variables names that could be associated with this object. More... | |
std::vector< OutputVariable > | outputVariables () const |
Get all output variables associated with this object, must run simulation to generate data. More... | |
boost::optional < openstudio::TimeSeries > | getData (const OutputVariable &variable, const std::string &envPeriod) const |
Get data associated with this output variable and this object. More... | |
std::vector< LifeCycleCost > | lifeCycleCosts () const |
Returns the list of all LifeCycleCosts that refer to this object. More... | |
std::vector< IdfObject > | removeLifeCycleCosts () |
Removes all LifeCycleCosts that refer to this object. More... | |
IddObjectType | iddObjectType () const |
This is a virtual function that will tell you the type of iddObject you are dealing with. More... | |
AdditionalProperties | additionalProperties () const |
Returns this object's additional properties, constructing a new object if necessary. More... | |
bool | hasAdditionalProperties () const |
Returns true if this object has additional properties. More... | |
std::vector< IdfObject > | removeAdditionalProperties () |
Removes all additional properties that refer to this object. More... | |
bool | setParent (ParentObject &newParent) |
set the parent, child may have to call non-const methods on the parent More... | |
bool | operator< (const ModelObject &right) const |
bool | operator== (const ModelObject &other) const |
equality test More... | |
bool | operator!= (const ModelObject &other) const |
inequality test More... | |
std::vector< ScheduleTypeKey > | getScheduleTypeKeys (const Schedule &schedule) const |
Return the ScheduleTypeKeys indicating how schedule is used in this object. More... | |
boost::optional< double > | getAutosizedValue (std::string valueName, std::string unitString) const |
Gets the autosized component value from the sql file. More... | |
virtual std::vector < EMSActuatorNames > | emsActuatorNames () const |
Return the names of the available ems actuators. More... | |
virtual std::vector< std::string > | emsInternalVariableNames () const |
Return the names of the available ems internal variables. More... | |
boost::optional< ModelObject > | connectedObject (unsigned port) const |
boost::optional< unsigned > | connectedObjectPort (unsigned port) const |
Static Public Member Functions | |
static IddObjectType | iddObjectType () |
Related Functions | |
(Note that these are not member functions.) | |
typedef std::vector < HeatPumpWaterToWaterEquationFitCooling > | HeatPumpWaterToWaterEquationFitCoolingVector |
typedef boost::optional < HeatPumpWaterToWaterEquationFitCooling > | OptionalHeatPumpWaterToWaterEquationFitCooling |
Related Functions inherited from openstudio::model::ParentObject | |
std::vector< ModelObject > | getRecursiveChildren (const ParentObject &object, bool includeLifeCycleCostsAndAdditionalProperties=false, bool includeUsedResources=true) |
Returns object and all other objects accessible by calling children() on encountered ParentObjects . More... | |
std::vector< ModelObject > | getRecursiveChildrenAndResources (const ModelObject &object) |
Returns object and all other objects accessible by calling children() and resources() on encountered ModelObjects . More... | |
Related Functions inherited from openstudio::model::ModelObject | |
std::vector< ResourceObject > | getRecursiveResources (const ModelObject &object) |
Returns all ResourceObjects accessible by recursively calling .resources() starting from object. More... | |
Additional Inherited Members | |
Protected Types inherited from openstudio::model::HVACComponent | |
typedef detail::HVACComponent_Impl | ImplType |
Protected Types inherited from openstudio::model::ModelObject | |
typedef detail::ModelObject_Impl | ImplType |
Protected Member Functions inherited from openstudio::model::HVACComponent | |
virtual std::vector< ModelObject > | children () const |
HVACComponent (IddObjectType type, const Model &model) | |
HVACComponent (std::shared_ptr< ImplType > impl) | |
Protected Member Functions inherited from openstudio::model::ParentObject | |
ParentObject (IddObjectType type, const Model &model) | |
Constructs a new ParentObject object in the model. More... | |
Protected Member Functions inherited from openstudio::model::ModelObject | |
ModelObject (IddObjectType type, const Model &model, bool fastName=false) | |
ModelObject (std::shared_ptr< detail::ModelObject_Impl > impl) | |
HeatPumpWaterToWaterEquationFitCooling is a WaterToWaterComponent that wraps the OpenStudio IDD object 'OS:HeatPump:WaterToWater:EquationFit:Cooling'.
|
explicit |
|
inlinevirtual |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitCooling::autosizedRatedCoolingCapacity | ( | ) | const |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitCooling::autosizedRatedCoolingPowerConsumption | ( | ) | const |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitCooling::autosizedReferenceLoadSideFlowRate | ( | ) | const |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitCooling::autosizedReferenceSourceSideFlowRate | ( | ) | const |
void openstudio::model::HeatPumpWaterToWaterEquationFitCooling::autosizeRatedCoolingCapacity | ( | ) |
void openstudio::model::HeatPumpWaterToWaterEquationFitCooling::autosizeRatedCoolingPowerConsumption | ( | ) |
void openstudio::model::HeatPumpWaterToWaterEquationFitCooling::autosizeReferenceLoadSideFlowRate | ( | ) |
void openstudio::model::HeatPumpWaterToWaterEquationFitCooling::autosizeReferenceSourceSideFlowRate | ( | ) |
boost::optional<HeatPumpWaterToWaterEquationFitHeating> openstudio::model::HeatPumpWaterToWaterEquationFitCooling::companionHeatingHeatPump | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::coolingCapacityCoefficient1 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::coolingCapacityCoefficient2 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::coolingCapacityCoefficient3 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::coolingCapacityCoefficient4 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::coolingCapacityCoefficient5 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::coolingCompressorPowerCoefficient1 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::coolingCompressorPowerCoefficient2 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::coolingCompressorPowerCoefficient3 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::coolingCompressorPowerCoefficient4 | ( | ) | const |
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::coolingCompressorPowerCoefficient5 | ( | ) | const |
|
static |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::isRatedCoolingCapacityAutosized | ( | ) | const |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::isRatedCoolingPowerConsumptionAutosized | ( | ) | const |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::isReferenceLoadSideFlowRateAutosized | ( | ) | const |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::isReferenceSourceSideFlowRateAutosized | ( | ) | const |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitCooling::ratedCoolingCapacity | ( | ) | const |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Cooling Capacity".
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitCooling::ratedCoolingPowerConsumption | ( | ) | const |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Cooling Power Consumption".
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::ratedLoadSideFlowRate | ( | ) | const |
Prior to EnergyPlus 8.7.0 this field was not autosizeable.
To preserve backwards compatibility this method will return -999.0 in autosized models.
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::ratedSourceSideFlowRate | ( | ) | const |
Prior to EnergyPlus 8.7.0 this field was not autosizeable.
To preserve backwards compatibility this method will return -999.0 in autosized models.
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::referenceCoefficientofPerformance | ( | ) | const |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitCooling::referenceLoadSideFlowRate | ( | ) | const |
boost::optional<double> openstudio::model::HeatPumpWaterToWaterEquationFitCooling::referenceSourceSideFlowRate | ( | ) | const |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setCompanionHeatingHeatPump | ( | const HeatPumpWaterToWaterEquationFitHeating & | companionHP | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setCoolingCapacityCoefficient1 | ( | double | coolingCapacityCoefficient1 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setCoolingCapacityCoefficient2 | ( | double | coolingCapacityCoefficient2 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setCoolingCapacityCoefficient3 | ( | double | coolingCapacityCoefficient3 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setCoolingCapacityCoefficient4 | ( | double | coolingCapacityCoefficient4 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setCoolingCapacityCoefficient5 | ( | double | coolingCapacityCoefficient5 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setCoolingCompressorPowerCoefficient1 | ( | double | coolingCompressorPowerCoefficient1 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setCoolingCompressorPowerCoefficient2 | ( | double | coolingCompressorPowerCoefficient2 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setCoolingCompressorPowerCoefficient3 | ( | double | coolingCompressorPowerCoefficient3 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setCoolingCompressorPowerCoefficient4 | ( | double | coolingCompressorPowerCoefficient4 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setCoolingCompressorPowerCoefficient5 | ( | double | coolingCompressorPowerCoefficient5 | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setRatedCoolingCapacity | ( | double | ratedCoolingCapacity | ) |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Cooling Capacity".
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setRatedCoolingPowerConsumption | ( | double | ratedCoolingPowerConsumption | ) |
In EnergyPlus 8.7.0 and above this field maps to the EnergyPlus field named "Reference Cooling Power Consumption".
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setRatedLoadSideFlowRate | ( | double | ratedLoadSideFlowRate | ) |
Synonym of setReferenceLoadSideFlowRate for backwards compatibility.
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setRatedSourceSideFlowRate | ( | double | ratedSourceSideFlowRate | ) |
Synonym of setReferenceLoadSideFlowRate for backwards compatibility.
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setReferenceCoefficientofPerformance | ( | double | referenceCoefficientofPerformance | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setReferenceLoadSideFlowRate | ( | double | referenceLoadSideFlowRate | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setReferenceSourceSideFlowRate | ( | double | referenceSourceSideFlowRate | ) |
bool openstudio::model::HeatPumpWaterToWaterEquationFitCooling::setSizingFactor | ( | double | sizingFactor | ) |
double openstudio::model::HeatPumpWaterToWaterEquationFitCooling::sizingFactor | ( | ) | const |
|
related |
|
related |