OpenStudio:model
 All Classes Namespaces Functions Variables Typedefs Enumerations Enumerator Pages
openstudio::model::ChillerElectricReformulatedEIR Member List

This is the complete list of members for openstudio::model::ChillerElectricReformulatedEIR, including all inherited members.

additionalProperties() const openstudio::model::ModelObject
addToNode(Node &node)openstudio::model::WaterToWaterComponentvirtual
addToSplitter(Splitter &splitter)openstudio::model::HVACComponent
addToTertiaryNode(Node &node)openstudio::model::WaterToWaterComponentvirtual
airLoopHVAC() const openstudio::model::HVACComponent
airLoopHVACOutdoorAirSystem() const openstudio::model::HVACComponent
allowableChildTypes() const openstudio::model::ParentObject
applySizingValues()openstudio::model::HVACComponent
autosize()openstudio::model::HVACComponent
autosizedDesignHeatRecoveryWaterFlowRate() const openstudio::model::ChillerElectricReformulatedEIR
autosizeDesignHeatRecoveryWaterFlowRate()openstudio::model::ChillerElectricReformulatedEIR
autosizedReferenceCapacity() const openstudio::model::ChillerElectricReformulatedEIR
autosizedReferenceChilledWaterFlowRate() const openstudio::model::ChillerElectricReformulatedEIR
autosizedReferenceCondenserWaterFlowRate() const openstudio::model::ChillerElectricReformulatedEIR
autosizeReferenceCapacity()openstudio::model::ChillerElectricReformulatedEIR
autosizeReferenceChilledWaterFlowRate()openstudio::model::ChillerElectricReformulatedEIR
autosizeReferenceCondenserWaterFlowRate()openstudio::model::ChillerElectricReformulatedEIR
children() const openstudio::model::HVACComponentprotectedvirtual
chilledWaterLoop() const openstudio::model::ChillerElectricReformulatedEIR
ChillerElectricReformulatedEIR(const Model &model, const Curve &CCFofT, const Curve &EItoCORFofT, const Curve &EItoCORFofPLR)openstudio::model::ChillerElectricReformulatedEIRexplicit
ChillerElectricReformulatedEIR(const Model &model)openstudio::model::ChillerElectricReformulatedEIRexplicit
ChillerElectricReformulatedEIRVector typedefopenstudio::model::ChillerElectricReformulatedEIRrelated
chillerFlowMode() const openstudio::model::ChillerElectricReformulatedEIR
clone(Model model) const openstudio::model::WaterToWaterComponentvirtual
openstudio::model::HVACComponent::clone() const openstudio::model::ModelObject
condenserHeatRecoveryRelativeCapacityFraction() const openstudio::model::ChillerElectricReformulatedEIR
condenserWaterLoop() const openstudio::model::ChillerElectricReformulatedEIR
connectedObject(unsigned port) const openstudio::model::ModelObject
connectedObjectPort(unsigned port) const openstudio::model::ModelObject
containingHVACComponent() const openstudio::model::HVACComponent
containingStraightComponent() const openstudio::model::HVACComponent
containingZoneHVACComponent() const openstudio::model::HVACComponent
coolingCapacityFunctionOfTemperature() const openstudio::model::ChillerElectricReformulatedEIR
createComponent() const openstudio::model::ModelObject
demandInletModelObject() const openstudio::model::WaterToWaterComponentvirtual
demandInletPort() const openstudio::model::WaterToWaterComponentvirtual
demandOutletModelObject() const openstudio::model::WaterToWaterComponentvirtual
demandOutletPort() const openstudio::model::WaterToWaterComponentvirtual
designHeatRecoveryWaterFlowRate() const openstudio::model::ChillerElectricReformulatedEIR
disconnect()openstudio::model::WaterToWaterComponent
electricInputToCoolingOutputRatioFunctionOfPLR() const openstudio::model::ChillerElectricReformulatedEIR
electricInputToCoolingOutputRatioFunctionOfPLRType() const openstudio::model::ChillerElectricReformulatedEIR
electricInputToCoolingOutputRatioFunctionOfTemperature() const openstudio::model::ChillerElectricReformulatedEIR
emsActuatorNames() const openstudio::model::ModelObjectvirtual
emsInternalVariableNames() const openstudio::model::ModelObjectvirtual
endUseSubcategory() const openstudio::model::ChillerElectricReformulatedEIR
fractionofCompressorElectricConsumptionRejectedbyCondenser() const openstudio::model::ChillerElectricReformulatedEIR
getAutosizedValue(std::string valueName, std::string unitString) const openstudio::model::ModelObject
getData(const OutputVariable &variable, const std::string &envPeriod) const openstudio::model::ModelObject
getModelObjectSources() const openstudio::model::ModelObjectinline
getModelObjectSources(IddObjectType iddObjectType) const openstudio::model::ModelObjectinline
getModelObjectTarget(unsigned index) const openstudio::model::ModelObjectinline
getModelObjectTargets() const openstudio::model::ModelObjectinline
getRecursiveChildren(const ParentObject &object, bool includeLifeCycleCostsAndAdditionalProperties=false, bool includeUsedResources=true)openstudio::model::ParentObjectrelated
getRecursiveChildrenAndResources(const ModelObject &object)openstudio::model::ParentObjectrelated
getRecursiveResources(const ModelObject &object)openstudio::model::ModelObjectrelated
getScheduleTypeKeys(const Schedule &schedule) const openstudio::model::ModelObject
hasAdditionalProperties() const openstudio::model::ModelObject
heatRecoveryInletHighTemperatureLimitSchedule() const openstudio::model::ChillerElectricReformulatedEIR
heatRecoveryLeavingTemperatureSetpointNode() const openstudio::model::ChillerElectricReformulatedEIR
heatRecoveryLoop() const openstudio::model::ChillerElectricReformulatedEIR
HVACComponent(IddObjectType type, const Model &model)openstudio::model::HVACComponentprotected
HVACComponent(std::shared_ptr< ImplType > impl)openstudio::model::HVACComponentexplicitprotected
iddObjectType()openstudio::model::ChillerElectricReformulatedEIRstatic
openstudio::model::WaterToWaterComponent::iddObjectType() const openstudio::model::ModelObject
ImplType typedefopenstudio::model::HVACComponentprotected
isChillerFlowModeDefaulted() const openstudio::model::ChillerElectricReformulatedEIR
isDesignHeatRecoveryWaterFlowRateAutosized() const openstudio::model::ChillerElectricReformulatedEIR
isFractionofCompressorElectricConsumptionRejectedbyCondenserDefaulted() const openstudio::model::ChillerElectricReformulatedEIR
isLeavingChilledWaterLowerTemperatureLimitDefaulted() const openstudio::model::ChillerElectricReformulatedEIR
isMaximumPartLoadRatioDefaulted() const openstudio::model::ChillerElectricReformulatedEIR
isMinimumPartLoadRatioDefaulted() const openstudio::model::ChillerElectricReformulatedEIR
isMinimumUnloadingRatioDefaulted() const openstudio::model::ChillerElectricReformulatedEIR
isOptimumPartLoadRatioDefaulted() const openstudio::model::ChillerElectricReformulatedEIR
isReferenceCapacityAutosized() const openstudio::model::ChillerElectricReformulatedEIR
isReferenceChilledWaterFlowRateAutosized() const openstudio::model::ChillerElectricReformulatedEIR
isReferenceCondenserWaterFlowRateAutosized() const openstudio::model::ChillerElectricReformulatedEIR
isReferenceLeavingChilledWaterTemperatureDefaulted() const openstudio::model::ChillerElectricReformulatedEIR
isReferenceLeavingCondenserWaterTemperatureDefaulted() const openstudio::model::ChillerElectricReformulatedEIR
isRemovable() const openstudio::model::HVACComponent
isSizingFactorDefaulted() const openstudio::model::ChillerElectricReformulatedEIR
leavingChilledWaterLowerTemperatureLimit() const openstudio::model::ChillerElectricReformulatedEIR
lifeCycleCosts() const openstudio::model::ModelObject
loop() const openstudio::model::HVACComponent
maximumPartLoadRatio() const openstudio::model::ChillerElectricReformulatedEIR
minimumPartLoadRatio() const openstudio::model::ChillerElectricReformulatedEIR
minimumUnloadingRatio() const openstudio::model::ChillerElectricReformulatedEIR
model() const openstudio::model::ModelObject
ModelObject(IddObjectType type, const Model &model, bool fastName=false)openstudio::model::ModelObjectexplicitprotected
ModelObject(std::shared_ptr< detail::ModelObject_Impl > impl)openstudio::model::ModelObjectexplicitprotected
operator!=(const ModelObject &other) const openstudio::model::ModelObject
operator<(const ModelObject &right) const openstudio::model::ModelObject
operator==(const ModelObject &other) const openstudio::model::ModelObject
optimumPartLoadRatio() const openstudio::model::ChillerElectricReformulatedEIR
OptionalChillerElectricReformulatedEIR typedefopenstudio::model::ChillerElectricReformulatedEIRrelated
outputVariableNames() const openstudio::model::ModelObject
outputVariables() const openstudio::model::ModelObject
parent() const openstudio::model::ModelObject
ParentObject(IddObjectType type, const Model &model)openstudio::model::ParentObjectprotected
plantLoop() const openstudio::model::WaterToWaterComponent
referenceCapacity() const openstudio::model::ChillerElectricReformulatedEIR
referenceChilledWaterFlowRate() const openstudio::model::ChillerElectricReformulatedEIR
referenceCondenserWaterFlowRate() const openstudio::model::ChillerElectricReformulatedEIR
referenceCOP() const openstudio::model::ChillerElectricReformulatedEIR
referenceLeavingChilledWaterTemperature() const openstudio::model::ChillerElectricReformulatedEIR
referenceLeavingCondenserWaterTemperature() const openstudio::model::ChillerElectricReformulatedEIR
remove()openstudio::model::WaterToWaterComponentvirtual
removeAdditionalProperties()openstudio::model::ModelObject
removeFromPlantLoop()openstudio::model::WaterToWaterComponent
removeFromSecondaryPlantLoop()openstudio::model::WaterToWaterComponent
removeFromTertiaryPlantLoop()openstudio::model::WaterToWaterComponent
removeLifeCycleCosts()openstudio::model::ModelObject
resetChillerFlowMode()openstudio::model::ChillerElectricReformulatedEIR
resetElectricInputToCoolingOutputRatioFunctionOfPLRType()openstudio::model::ChillerElectricReformulatedEIR
resetFractionofCompressorElectricConsumptionRejectedbyCondenser()openstudio::model::ChillerElectricReformulatedEIR
resetHeatRecoveryInletHighTemperatureLimitSchedule()openstudio::model::ChillerElectricReformulatedEIR
resetHeatRecoveryLeavingTemperatureSetpointNode()openstudio::model::ChillerElectricReformulatedEIR
resetLeavingChilledWaterLowerTemperatureLimit()openstudio::model::ChillerElectricReformulatedEIR
resetMaximumPartLoadRatio()openstudio::model::ChillerElectricReformulatedEIR
resetMinimumPartLoadRatio()openstudio::model::ChillerElectricReformulatedEIR
resetMinimumUnloadingRatio()openstudio::model::ChillerElectricReformulatedEIR
resetOptimumPartLoadRatio()openstudio::model::ChillerElectricReformulatedEIR
resetReferenceChilledWaterFlowRate()openstudio::model::ChillerElectricReformulatedEIR
resetReferenceCondenserWaterFlowRate()openstudio::model::ChillerElectricReformulatedEIR
resetReferenceLeavingChilledWaterTemperature()openstudio::model::ChillerElectricReformulatedEIR
resetReferenceLeavingCondenserWaterTemperature()openstudio::model::ChillerElectricReformulatedEIR
resetSizingFactor()openstudio::model::ChillerElectricReformulatedEIR
resources() const openstudio::model::ModelObject
secondaryPlantLoop() const openstudio::model::WaterToWaterComponent
setChillerFlowMode(std::string chillerFlowMode)openstudio::model::ChillerElectricReformulatedEIR
setCondenserHeatRecoveryRelativeCapacityFraction(double condenserHeatRecoveryRelativeCapacityFraction)openstudio::model::ChillerElectricReformulatedEIR
setCoolingCapacityFunctionOfTemperature(const Curve &)openstudio::model::ChillerElectricReformulatedEIR
setDesignHeatRecoveryWaterFlowRate(double designHeatRecoveryWaterFlowRate)openstudio::model::ChillerElectricReformulatedEIR
setElectricInputToCoolingOutputRatioFunctionOfPLR(const Curve &)openstudio::model::ChillerElectricReformulatedEIR
setElectricInputToCoolingOutputRatioFunctionOfPLRType(std::string electricInputToCoolingOutputRatioFunctionOfPLRType)openstudio::model::ChillerElectricReformulatedEIR
setElectricInputToCoolingOutputRatioFunctionOfTemperature(const Curve &)openstudio::model::ChillerElectricReformulatedEIR
setEndUseSubcategory(const std::string &endUseSubcategory)openstudio::model::ChillerElectricReformulatedEIR
setFractionofCompressorElectricConsumptionRejectedbyCondenser(double fractionofCompressorElectricConsumptionRejectedbyCondenser)openstudio::model::ChillerElectricReformulatedEIR
setHeatRecoveryInletHighTemperatureLimitSchedule(Schedule &s)openstudio::model::ChillerElectricReformulatedEIR
setHeatRecoveryLeavingTemperatureSetpointNode(const Node &node)openstudio::model::ChillerElectricReformulatedEIR
setLeavingChilledWaterLowerTemperatureLimit(double leavingChilledWaterLowerTemperatureLimit)openstudio::model::ChillerElectricReformulatedEIR
setMaximumPartLoadRatio(double maximumPartLoadRatio)openstudio::model::ChillerElectricReformulatedEIR
setMinimumPartLoadRatio(double minimumPartLoadRatio)openstudio::model::ChillerElectricReformulatedEIR
setMinimumUnloadingRatio(double minimumUnloadingRatio)openstudio::model::ChillerElectricReformulatedEIR
setOptimumPartLoadRatio(double optimumPartLoadRatio)openstudio::model::ChillerElectricReformulatedEIR
setParent(ParentObject &newParent)openstudio::model::ModelObject
setReferenceCapacity(boost::optional< double > referenceCapacity)openstudio::model::ChillerElectricReformulatedEIR
setReferenceCapacity(double referenceCapacity)openstudio::model::ChillerElectricReformulatedEIR
setReferenceChilledWaterFlowRate(boost::optional< double > referenceChilledWaterFlowRate)openstudio::model::ChillerElectricReformulatedEIR
setReferenceChilledWaterFlowRate(double referenceChilledWaterFlowRate)openstudio::model::ChillerElectricReformulatedEIR
setReferenceCondenserWaterFlowRate(boost::optional< double > referenceCondenserWaterFlowRate)openstudio::model::ChillerElectricReformulatedEIR
setReferenceCondenserWaterFlowRate(double referenceCondenserWaterFlowRate)openstudio::model::ChillerElectricReformulatedEIR
setReferenceCOP(double referenceCOP)openstudio::model::ChillerElectricReformulatedEIR
setReferenceLeavingChilledWaterTemperature(double referenceLeavingChilledWaterTemperature)openstudio::model::ChillerElectricReformulatedEIR
setReferenceLeavingCondenserWaterTemperature(double referenceLeavingCondenserWaterTemperature)openstudio::model::ChillerElectricReformulatedEIR
setSizingFactor(double sizingFactor)openstudio::model::ChillerElectricReformulatedEIR
sizingFactor() const openstudio::model::ChillerElectricReformulatedEIR
supplyInletModelObject() const openstudio::model::WaterToWaterComponentvirtual
supplyInletPort() const openstudio::model::WaterToWaterComponentvirtual
supplyOutletModelObject() const openstudio::model::WaterToWaterComponentvirtual
supplyOutletPort() const openstudio::model::WaterToWaterComponentvirtual
tertiaryInletModelObject() const openstudio::model::WaterToWaterComponent
tertiaryOutletModelObject() const openstudio::model::WaterToWaterComponent
tertiaryPlantLoop() const openstudio::model::WaterToWaterComponent
validChillerFlowModeValues()openstudio::model::ChillerElectricReformulatedEIRstatic
WaterToWaterComponent(IddObjectType type, const Model &model)openstudio::model::WaterToWaterComponent
~ChillerElectricReformulatedEIR()openstudio::model::ChillerElectricReformulatedEIRinlinevirtual
~HVACComponent()openstudio::model::HVACComponentinlinevirtual
~ModelObject()openstudio::model::ModelObjectinlinevirtual
~ParentObject()openstudio::model::ParentObjectinlinevirtual
~WaterToWaterComponent()openstudio::model::WaterToWaterComponentinlinevirtual