OpenStudio:model
 All Classes Namespaces Functions Variables Typedefs Enumerations Enumerator Pages
Public Member Functions | Static Public Member Functions | Related Functions | List of all members
openstudio::model::ChillerElectricReformulatedEIR Class Reference

#include <ChillerElectricReformulatedEIR.hpp>

+ Inheritance diagram for openstudio::model::ChillerElectricReformulatedEIR:

Public Member Functions

 ChillerElectricReformulatedEIR (const Model &model, const Curve &CCFofT, const Curve &EItoCORFofT, const Curve &EItoCORFofPLR)
 
 ChillerElectricReformulatedEIR (const Model &model)
 
virtual ~ChillerElectricReformulatedEIR ()
 
Getters
boost::optional< double > referenceCapacity () const
 
bool isReferenceCapacityAutosized () const
 
double referenceCOP () const
 
double referenceLeavingChilledWaterTemperature () const
 
bool isReferenceLeavingChilledWaterTemperatureDefaulted () const
 
double referenceLeavingCondenserWaterTemperature () const
 
bool isReferenceLeavingCondenserWaterTemperatureDefaulted () const
 
boost::optional< double > referenceChilledWaterFlowRate () const
 
bool isReferenceChilledWaterFlowRateAutosized () const
 
boost::optional< double > referenceCondenserWaterFlowRate () const
 
bool isReferenceCondenserWaterFlowRateAutosized () const
 
Curve coolingCapacityFunctionOfTemperature () const
 
Curve electricInputToCoolingOutputRatioFunctionOfTemperature () const
 
std::string electricInputToCoolingOutputRatioFunctionOfPLRType () const
 
Curve electricInputToCoolingOutputRatioFunctionOfPLR () const
 
double minimumPartLoadRatio () const
 
bool isMinimumPartLoadRatioDefaulted () const
 
double maximumPartLoadRatio () const
 
bool isMaximumPartLoadRatioDefaulted () const
 
double optimumPartLoadRatio () const
 
bool isOptimumPartLoadRatioDefaulted () const
 
double minimumUnloadingRatio () const
 
bool isMinimumUnloadingRatioDefaulted () const
 
double fractionofCompressorElectricConsumptionRejectedbyCondenser () const
 
bool isFractionofCompressorElectricConsumptionRejectedbyCondenserDefaulted () const
 
double leavingChilledWaterLowerTemperatureLimit () const
 
bool isLeavingChilledWaterLowerTemperatureLimitDefaulted () const
 
std::string chillerFlowMode () const
 
bool isChillerFlowModeDefaulted () const
 
boost::optional< double > designHeatRecoveryWaterFlowRate () const
 
bool isDesignHeatRecoveryWaterFlowRateAutosized () const
 
double sizingFactor () const
 
bool isSizingFactorDefaulted () const
 
double condenserHeatRecoveryRelativeCapacityFraction () const
 
boost::optional< ScheduleheatRecoveryInletHighTemperatureLimitSchedule () const
 
boost::optional< NodeheatRecoveryLeavingTemperatureSetpointNode () const
 
std::string endUseSubcategory () const
 
Setters
bool setReferenceCapacity (boost::optional< double > referenceCapacity)
 
bool setReferenceCapacity (double referenceCapacity)
 
void autosizeReferenceCapacity ()
 
bool setReferenceCOP (double referenceCOP)
 
bool setReferenceLeavingChilledWaterTemperature (double referenceLeavingChilledWaterTemperature)
 
void resetReferenceLeavingChilledWaterTemperature ()
 
bool setReferenceLeavingCondenserWaterTemperature (double referenceLeavingCondenserWaterTemperature)
 
void resetReferenceLeavingCondenserWaterTemperature ()
 
bool setReferenceChilledWaterFlowRate (boost::optional< double > referenceChilledWaterFlowRate)
 
bool setReferenceChilledWaterFlowRate (double referenceChilledWaterFlowRate)
 
void resetReferenceChilledWaterFlowRate ()
 
void autosizeReferenceChilledWaterFlowRate ()
 
bool setReferenceCondenserWaterFlowRate (boost::optional< double > referenceCondenserWaterFlowRate)
 
bool setReferenceCondenserWaterFlowRate (double referenceCondenserWaterFlowRate)
 
void resetReferenceCondenserWaterFlowRate ()
 
void autosizeReferenceCondenserWaterFlowRate ()
 
bool setCoolingCapacityFunctionOfTemperature (const Curve &)
 
bool setElectricInputToCoolingOutputRatioFunctionOfTemperature (const Curve &)
 
bool setElectricInputToCoolingOutputRatioFunctionOfPLRType (std::string electricInputToCoolingOutputRatioFunctionOfPLRType)
 
void resetElectricInputToCoolingOutputRatioFunctionOfPLRType ()
 
bool setElectricInputToCoolingOutputRatioFunctionOfPLR (const Curve &)
 
bool setMinimumPartLoadRatio (double minimumPartLoadRatio)
 
void resetMinimumPartLoadRatio ()
 
bool setMaximumPartLoadRatio (double maximumPartLoadRatio)
 
void resetMaximumPartLoadRatio ()
 
bool setOptimumPartLoadRatio (double optimumPartLoadRatio)
 
void resetOptimumPartLoadRatio ()
 
bool setMinimumUnloadingRatio (double minimumUnloadingRatio)
 
void resetMinimumUnloadingRatio ()
 
bool setFractionofCompressorElectricConsumptionRejectedbyCondenser (double fractionofCompressorElectricConsumptionRejectedbyCondenser)
 
void resetFractionofCompressorElectricConsumptionRejectedbyCondenser ()
 
bool setLeavingChilledWaterLowerTemperatureLimit (double leavingChilledWaterLowerTemperatureLimit)
 
void resetLeavingChilledWaterLowerTemperatureLimit ()
 
bool setChillerFlowMode (std::string chillerFlowMode)
 
void resetChillerFlowMode ()
 
bool setDesignHeatRecoveryWaterFlowRate (double designHeatRecoveryWaterFlowRate)
 
void autosizeDesignHeatRecoveryWaterFlowRate ()
 
bool setSizingFactor (double sizingFactor)
 
void resetSizingFactor ()
 
bool setCondenserHeatRecoveryRelativeCapacityFraction (double condenserHeatRecoveryRelativeCapacityFraction)
 
bool setHeatRecoveryInletHighTemperatureLimitSchedule (Schedule &s)
 
void resetHeatRecoveryInletHighTemperatureLimitSchedule ()
 
bool setHeatRecoveryLeavingTemperatureSetpointNode (const Node &node)
 
void resetHeatRecoveryLeavingTemperatureSetpointNode ()
 
bool setEndUseSubcategory (const std::string &endUseSubcategory)
 
Other
boost::optional< double > autosizedReferenceCapacity () const
 
boost::optional< double > autosizedReferenceChilledWaterFlowRate () const
 
boost::optional< double > autosizedReferenceCondenserWaterFlowRate () const
 
boost::optional< double > autosizedDesignHeatRecoveryWaterFlowRate () const
 
boost::optional< PlantLoopchilledWaterLoop () const
 Convenience Function to return the Chilled Water Loop (chiller on supply) More...
 
boost::optional< PlantLoopcondenserWaterLoop () const
 Convenience Function to return the Condenser Water Loop (chiller on demand side) More...
 
boost::optional< PlantLoopheatRecoveryLoop () const
 Convenience Function to return the Heat Recovery Loop (chiller on demand side - tertiary) More...
 
- Public Member Functions inherited from openstudio::model::WaterToWaterComponent
virtual bool addToNode (Node &node)
 
virtual bool addToTertiaryNode (Node &node)
 Add this WaterToWaterComponent to a tertiaryPlantLoop by making connections to the tertiary inlet and outlet. More...
 
virtual ModelObject clone (Model model) const
 
virtual boost::optional
< ModelObject
demandInletModelObject () const
 Returns the optional ModelObject connected to the demand inlet port. More...
 
virtual unsigned demandInletPort () const
 Returns the demand inlet port. More...
 
virtual boost::optional
< ModelObject
demandOutletModelObject () const
 Returns the optional ModelObject connected to the demand outlet port. More...
 
virtual unsigned demandOutletPort () const
 Returns the demand outlet port. More...
 
void disconnect ()
 
boost::optional< PlantLoopplantLoop () const
 Returns the optional PlantLoop object that the HVAC component is a supply component on. More...
 
virtual std::vector
< openstudio::IdfObject > 
remove ()
 
bool removeFromPlantLoop ()
 Removes the component from the plantLoop if one is attached. More...
 
bool removeFromSecondaryPlantLoop ()
 Removes the component from the secondaryPlantLoop if one is attached. More...
 
bool removeFromTertiaryPlantLoop ()
 Removes the component from the tertiaryPlantLoop if one is attached. More...
 
boost::optional< PlantLoopsecondaryPlantLoop () const
 Returns the optional PlantLoop object that the HVAC component is a demand component on. More...
 
virtual boost::optional
< ModelObject
supplyInletModelObject () const
 Returns the optional ModelObject connected to the supply inlet port. More...
 
virtual unsigned supplyInletPort () const
 Returns the supply inlet port. More...
 
virtual boost::optional
< ModelObject
supplyOutletModelObject () const
 Returns the optional ModelObject connected to the supply outlet port. More...
 
virtual unsigned supplyOutletPort () const
 Returns the supply outlet port. More...
 
boost::optional< ModelObjecttertiaryInletModelObject () const
 Returns the optional ModelObject connected to the tertiary inlet. More...
 
boost::optional< ModelObjecttertiaryOutletModelObject () const
 Returns the optional ModelObject connected to the tertiary outlet. More...
 
boost::optional< PlantLooptertiaryPlantLoop () const
 Tertiary plant loop applies to a limited number of WaterToWaterComponent types that interact with three plant systems. More...
 
 WaterToWaterComponent (IddObjectType type, const Model &model)
 
virtual ~WaterToWaterComponent ()
 
- Public Member Functions inherited from openstudio::model::HVACComponent
bool addToNode (Node &node)
 Adds this object to a new system node and returns a boolean indicating if the addition was successful. More...
 
bool addToSplitter (Splitter &splitter)
 Adds this object to a splitter by creating a new branch. More...
 
boost::optional< AirLoopHVACairLoopHVAC () const
 Returns the optional AirLoopHVAC object that the HVAC component is attached to. More...
 
boost::optional
< AirLoopHVACOutdoorAirSystem
airLoopHVACOutdoorAirSystem () const
 Returns the optional AirLoopHVACOutdoorAirSystem that the HVAC component is attached to. More...
 
void applySizingValues ()
 
void autosize ()
 Returns the optional ModelObject connected to this object's port. More...
 
boost::optional< HVACComponentcontainingHVACComponent () const
 EnergyPlus unitary equipment and air terminals are typically composed of other HVAC components. More...
 
boost::optional
< StraightComponent
containingStraightComponent () const
 
boost::optional
< ZoneHVACComponent
containingZoneHVACComponent () const
 Returns any ZoneHVACComponent that contains this HVACComponent. More...
 
void disconnect ()
 Removes all connections to other HVACComponent objects. More...
 
bool isRemovable () const
 Indicates if the HVACComponent can be removed from the model. More...
 
boost::optional< Looploop () const
 Returns the optional Loop object that the HVAC component is attached to. More...
 
boost::optional< PlantLoopplantLoop () const
 Returns the optional PlantLoop object that the HVAC component is attached to. More...
 
std::vector< IdfObject > remove ()
 Removes the HVACComponent from the model only if isRemovable() return true. More...
 
virtual ~HVACComponent ()
 
- Public Member Functions inherited from openstudio::model::ParentObject
std::vector< IddObjectType > allowableChildTypes () const
 Returns a vector of allowable children types. More...
 
std::vector< ModelObjectchildren () const
 Return direct child objects in the Model. More...
 
virtual ~ParentObject ()
 
- Public Member Functions inherited from openstudio::model::ModelObject
virtual ~ModelObject ()
 
ModelObject clone () const
 Creates a deep copy of this object, placing it in this object's model(). More...
 
ModelObject clone (Model model) const
 Creates a deep copy of this object, placing it in model. More...
 
Component createComponent () const
 Method for creating sharable Model snippets. More...
 
Model model () const
 Returns the Model that contains this object. More...
 
boost::optional< ParentObjectparent () const
 Return this object's parent in the hierarchy, if it has one. More...
 
std::vector< ResourceObjectresources () const
 Get the resources directly used by this ModelObject. More...
 
template<typename T >
std::vector< T > getModelObjectSources () const
 Get all objects of type T that point to this object. More...
 
template<typename T >
std::vector< T > getModelObjectSources (IddObjectType iddObjectType) const
 Get all objects of type T that point to this object. More...
 
template<typename T >
boost::optional< T > getModelObjectTarget (unsigned index) const
 Get the object of type T pointed to by this object from field index. More...
 
template<typename T >
std::vector< T > getModelObjectTargets () const
 Get all objects of type T to which this object points. More...
 
const std::vector< std::string > & outputVariableNames () const
 Get all output variables names that could be associated with this object. More...
 
std::vector< OutputVariableoutputVariables () const
 Get all output variables associated with this object, must run simulation to generate data. More...
 
boost::optional
< openstudio::TimeSeries > 
getData (const OutputVariable &variable, const std::string &envPeriod) const
 Get data associated with this output variable and this object. More...
 
std::vector< LifeCycleCostlifeCycleCosts () const
 Returns the list of all LifeCycleCosts that refer to this object. More...
 
std::vector< IdfObject > removeLifeCycleCosts ()
 Removes all LifeCycleCosts that refer to this object. More...
 
IddObjectType iddObjectType () const
 This is a virtual function that will tell you the type of iddObject you are dealing with. More...
 
AdditionalProperties additionalProperties () const
 Returns this object's additional properties, constructing a new object if necessary. More...
 
bool hasAdditionalProperties () const
 Returns true if this object has additional properties. More...
 
std::vector< IdfObject > removeAdditionalProperties ()
 Removes all additional properties that refer to this object. More...
 
bool setParent (ParentObject &newParent)
 set the parent, child may have to call non-const methods on the parent More...
 
bool operator< (const ModelObject &right) const
 
bool operator== (const ModelObject &other) const
 equality test More...
 
bool operator!= (const ModelObject &other) const
 inequality test More...
 
std::vector< ScheduleTypeKeygetScheduleTypeKeys (const Schedule &schedule) const
 Return the ScheduleTypeKeys indicating how schedule is used in this object. More...
 
boost::optional< double > getAutosizedValue (std::string valueName, std::string unitString) const
 Gets the autosized component value from the sql file. More...
 
virtual std::vector
< EMSActuatorNames
emsActuatorNames () const
 Return the names of the available ems actuators. More...
 
virtual std::vector< std::string > emsInternalVariableNames () const
 Return the names of the available ems internal variables. More...
 
boost::optional< ModelObjectconnectedObject (unsigned port) const
 
boost::optional< unsigned > connectedObjectPort (unsigned port) const
 

Static Public Member Functions

static IddObjectType iddObjectType ()
 
static std::vector< std::string > validChillerFlowModeValues ()
 

Related Functions

(Note that these are not member functions.)

typedef std::vector
< ChillerElectricReformulatedEIR
ChillerElectricReformulatedEIRVector
 
typedef boost::optional
< ChillerElectricReformulatedEIR
OptionalChillerElectricReformulatedEIR
 

Additional Inherited Members

- Protected Types inherited from openstudio::model::HVACComponent
typedef detail::HVACComponent_Impl ImplType
 
- Protected Types inherited from openstudio::model::ModelObject
typedef detail::ModelObject_Impl ImplType
 
- Protected Member Functions inherited from openstudio::model::HVACComponent
virtual std::vector< ModelObjectchildren () const
 
 HVACComponent (IddObjectType type, const Model &model)
 
 HVACComponent (std::shared_ptr< ImplType > impl)
 
- Protected Member Functions inherited from openstudio::model::ParentObject
 ParentObject (IddObjectType type, const Model &model)
 Constructs a new ParentObject object in the model. More...
 
- Protected Member Functions inherited from openstudio::model::ModelObject
 ModelObject (IddObjectType type, const Model &model, bool fastName=false)
 
 ModelObject (std::shared_ptr< detail::ModelObject_Impl > impl)
 

Detailed Description

ChillerElectricReformulatedEIR is a StraightComponent that wraps the OpenStudio IDD object 'OS:Chiller:Electric:EIR'.

Constructor & Destructor Documentation

openstudio::model::ChillerElectricReformulatedEIR::ChillerElectricReformulatedEIR ( const Model model,
const Curve CCFofT,
const Curve EItoCORFofT,
const Curve EItoCORFofPLR 
)
explicit
Parameters
modelthe Model to put the chiller in
CCFofTCooling Capacity as a Function of Temp
EItoCORFofTElectric Input to Cooling Output Ratio as a Function of Temp
EItoCORFofPLRElectric Input to Cooling Output Ratio as a Function of Partial Load Ratio
openstudio::model::ChillerElectricReformulatedEIR::ChillerElectricReformulatedEIR ( const Model model)
explicit
virtual openstudio::model::ChillerElectricReformulatedEIR::~ChillerElectricReformulatedEIR ( )
inlinevirtual

Member Function Documentation

boost::optional<double> openstudio::model::ChillerElectricReformulatedEIR::autosizedDesignHeatRecoveryWaterFlowRate ( ) const
void openstudio::model::ChillerElectricReformulatedEIR::autosizeDesignHeatRecoveryWaterFlowRate ( )
boost::optional<double> openstudio::model::ChillerElectricReformulatedEIR::autosizedReferenceCapacity ( ) const
boost::optional<double> openstudio::model::ChillerElectricReformulatedEIR::autosizedReferenceChilledWaterFlowRate ( ) const
boost::optional<double> openstudio::model::ChillerElectricReformulatedEIR::autosizedReferenceCondenserWaterFlowRate ( ) const
void openstudio::model::ChillerElectricReformulatedEIR::autosizeReferenceCapacity ( )
void openstudio::model::ChillerElectricReformulatedEIR::autosizeReferenceChilledWaterFlowRate ( )
void openstudio::model::ChillerElectricReformulatedEIR::autosizeReferenceCondenserWaterFlowRate ( )
boost::optional<PlantLoop> openstudio::model::ChillerElectricReformulatedEIR::chilledWaterLoop ( ) const

Convenience Function to return the Chilled Water Loop (chiller on supply)

std::string openstudio::model::ChillerElectricReformulatedEIR::chillerFlowMode ( ) const
double openstudio::model::ChillerElectricReformulatedEIR::condenserHeatRecoveryRelativeCapacityFraction ( ) const
boost::optional<PlantLoop> openstudio::model::ChillerElectricReformulatedEIR::condenserWaterLoop ( ) const

Convenience Function to return the Condenser Water Loop (chiller on demand side)

Curve openstudio::model::ChillerElectricReformulatedEIR::coolingCapacityFunctionOfTemperature ( ) const
boost::optional<double> openstudio::model::ChillerElectricReformulatedEIR::designHeatRecoveryWaterFlowRate ( ) const
Curve openstudio::model::ChillerElectricReformulatedEIR::electricInputToCoolingOutputRatioFunctionOfPLR ( ) const
std::string openstudio::model::ChillerElectricReformulatedEIR::electricInputToCoolingOutputRatioFunctionOfPLRType ( ) const
Curve openstudio::model::ChillerElectricReformulatedEIR::electricInputToCoolingOutputRatioFunctionOfTemperature ( ) const
std::string openstudio::model::ChillerElectricReformulatedEIR::endUseSubcategory ( ) const
double openstudio::model::ChillerElectricReformulatedEIR::fractionofCompressorElectricConsumptionRejectedbyCondenser ( ) const
boost::optional<Schedule> openstudio::model::ChillerElectricReformulatedEIR::heatRecoveryInletHighTemperatureLimitSchedule ( ) const
boost::optional<Node> openstudio::model::ChillerElectricReformulatedEIR::heatRecoveryLeavingTemperatureSetpointNode ( ) const
boost::optional<PlantLoop> openstudio::model::ChillerElectricReformulatedEIR::heatRecoveryLoop ( ) const

Convenience Function to return the Heat Recovery Loop (chiller on demand side - tertiary)

static IddObjectType openstudio::model::ChillerElectricReformulatedEIR::iddObjectType ( )
static
bool openstudio::model::ChillerElectricReformulatedEIR::isChillerFlowModeDefaulted ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isDesignHeatRecoveryWaterFlowRateAutosized ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isFractionofCompressorElectricConsumptionRejectedbyCondenserDefaulted ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isLeavingChilledWaterLowerTemperatureLimitDefaulted ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isMaximumPartLoadRatioDefaulted ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isMinimumPartLoadRatioDefaulted ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isMinimumUnloadingRatioDefaulted ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isOptimumPartLoadRatioDefaulted ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isReferenceCapacityAutosized ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isReferenceChilledWaterFlowRateAutosized ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isReferenceCondenserWaterFlowRateAutosized ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isReferenceLeavingChilledWaterTemperatureDefaulted ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isReferenceLeavingCondenserWaterTemperatureDefaulted ( ) const
bool openstudio::model::ChillerElectricReformulatedEIR::isSizingFactorDefaulted ( ) const
double openstudio::model::ChillerElectricReformulatedEIR::leavingChilledWaterLowerTemperatureLimit ( ) const
double openstudio::model::ChillerElectricReformulatedEIR::maximumPartLoadRatio ( ) const
double openstudio::model::ChillerElectricReformulatedEIR::minimumPartLoadRatio ( ) const
double openstudio::model::ChillerElectricReformulatedEIR::minimumUnloadingRatio ( ) const
double openstudio::model::ChillerElectricReformulatedEIR::optimumPartLoadRatio ( ) const
boost::optional<double> openstudio::model::ChillerElectricReformulatedEIR::referenceCapacity ( ) const
boost::optional<double> openstudio::model::ChillerElectricReformulatedEIR::referenceChilledWaterFlowRate ( ) const
boost::optional<double> openstudio::model::ChillerElectricReformulatedEIR::referenceCondenserWaterFlowRate ( ) const
double openstudio::model::ChillerElectricReformulatedEIR::referenceCOP ( ) const
double openstudio::model::ChillerElectricReformulatedEIR::referenceLeavingChilledWaterTemperature ( ) const
double openstudio::model::ChillerElectricReformulatedEIR::referenceLeavingCondenserWaterTemperature ( ) const
void openstudio::model::ChillerElectricReformulatedEIR::resetChillerFlowMode ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetElectricInputToCoolingOutputRatioFunctionOfPLRType ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetFractionofCompressorElectricConsumptionRejectedbyCondenser ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetHeatRecoveryInletHighTemperatureLimitSchedule ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetHeatRecoveryLeavingTemperatureSetpointNode ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetLeavingChilledWaterLowerTemperatureLimit ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetMaximumPartLoadRatio ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetMinimumPartLoadRatio ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetMinimumUnloadingRatio ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetOptimumPartLoadRatio ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetReferenceChilledWaterFlowRate ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetReferenceCondenserWaterFlowRate ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetReferenceLeavingChilledWaterTemperature ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetReferenceLeavingCondenserWaterTemperature ( )
void openstudio::model::ChillerElectricReformulatedEIR::resetSizingFactor ( )
bool openstudio::model::ChillerElectricReformulatedEIR::setChillerFlowMode ( std::string  chillerFlowMode)
bool openstudio::model::ChillerElectricReformulatedEIR::setCondenserHeatRecoveryRelativeCapacityFraction ( double  condenserHeatRecoveryRelativeCapacityFraction)
bool openstudio::model::ChillerElectricReformulatedEIR::setCoolingCapacityFunctionOfTemperature ( const Curve )
bool openstudio::model::ChillerElectricReformulatedEIR::setDesignHeatRecoveryWaterFlowRate ( double  designHeatRecoveryWaterFlowRate)
bool openstudio::model::ChillerElectricReformulatedEIR::setElectricInputToCoolingOutputRatioFunctionOfPLR ( const Curve )
bool openstudio::model::ChillerElectricReformulatedEIR::setElectricInputToCoolingOutputRatioFunctionOfPLRType ( std::string  electricInputToCoolingOutputRatioFunctionOfPLRType)
bool openstudio::model::ChillerElectricReformulatedEIR::setElectricInputToCoolingOutputRatioFunctionOfTemperature ( const Curve )
bool openstudio::model::ChillerElectricReformulatedEIR::setEndUseSubcategory ( const std::string &  endUseSubcategory)
bool openstudio::model::ChillerElectricReformulatedEIR::setFractionofCompressorElectricConsumptionRejectedbyCondenser ( double  fractionofCompressorElectricConsumptionRejectedbyCondenser)
bool openstudio::model::ChillerElectricReformulatedEIR::setHeatRecoveryInletHighTemperatureLimitSchedule ( Schedule s)
bool openstudio::model::ChillerElectricReformulatedEIR::setHeatRecoveryLeavingTemperatureSetpointNode ( const Node node)
bool openstudio::model::ChillerElectricReformulatedEIR::setLeavingChilledWaterLowerTemperatureLimit ( double  leavingChilledWaterLowerTemperatureLimit)
bool openstudio::model::ChillerElectricReformulatedEIR::setMaximumPartLoadRatio ( double  maximumPartLoadRatio)
bool openstudio::model::ChillerElectricReformulatedEIR::setMinimumPartLoadRatio ( double  minimumPartLoadRatio)
bool openstudio::model::ChillerElectricReformulatedEIR::setMinimumUnloadingRatio ( double  minimumUnloadingRatio)
bool openstudio::model::ChillerElectricReformulatedEIR::setOptimumPartLoadRatio ( double  optimumPartLoadRatio)
bool openstudio::model::ChillerElectricReformulatedEIR::setReferenceCapacity ( boost::optional< double >  referenceCapacity)
bool openstudio::model::ChillerElectricReformulatedEIR::setReferenceCapacity ( double  referenceCapacity)
bool openstudio::model::ChillerElectricReformulatedEIR::setReferenceChilledWaterFlowRate ( boost::optional< double >  referenceChilledWaterFlowRate)
bool openstudio::model::ChillerElectricReformulatedEIR::setReferenceChilledWaterFlowRate ( double  referenceChilledWaterFlowRate)
bool openstudio::model::ChillerElectricReformulatedEIR::setReferenceCondenserWaterFlowRate ( boost::optional< double >  referenceCondenserWaterFlowRate)
bool openstudio::model::ChillerElectricReformulatedEIR::setReferenceCondenserWaterFlowRate ( double  referenceCondenserWaterFlowRate)
bool openstudio::model::ChillerElectricReformulatedEIR::setReferenceCOP ( double  referenceCOP)
bool openstudio::model::ChillerElectricReformulatedEIR::setReferenceLeavingChilledWaterTemperature ( double  referenceLeavingChilledWaterTemperature)
bool openstudio::model::ChillerElectricReformulatedEIR::setReferenceLeavingCondenserWaterTemperature ( double  referenceLeavingCondenserWaterTemperature)
bool openstudio::model::ChillerElectricReformulatedEIR::setSizingFactor ( double  sizingFactor)
double openstudio::model::ChillerElectricReformulatedEIR::sizingFactor ( ) const
static std::vector<std::string> openstudio::model::ChillerElectricReformulatedEIR::validChillerFlowModeValues ( )
static

Friends And Related Function Documentation