#include <ZoneHVACPackagedTerminalHeatPump.hpp>
Public Member Functions | |
Constructors and Destructors | |
ZoneHVACPackagedTerminalHeatPump (const Model &model, Schedule &availabilitySchedule, HVACComponent &supplyAirFan, HVACComponent &heatingCoil, HVACComponent &coolingCoil, HVACComponent &supplementalHeatingCoil) | |
virtual | ~ZoneHVACPackagedTerminalHeatPump () |
Getters | |
Schedule | availabilitySchedule () const |
std::string | outdoorAirMixerObjectType () const |
std::string | outdoorAirMixerName () const |
boost::optional< double > | supplyAirFlowRateDuringCoolingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Supply Air Flow Rate". More... | |
bool | isSupplyAirFlowRateDuringCoolingOperationAutosized () const |
boost::optional< double > | supplyAirFlowRateDuringHeatingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Supply Air Flow Rate". More... | |
bool | isSupplyAirFlowRateDuringHeatingOperationAutosized () const |
boost::optional< double > | supplyAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Supply Air Flow Rate". More... | |
bool | isSupplyAirFlowRateWhenNoCoolingorHeatingisNeededAutosized () const |
boost::optional< double > | outdoorAirFlowRateDuringCoolingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Outdoor Air Flow Rate". More... | |
bool | isOutdoorAirFlowRateDuringCoolingOperationAutosized () const |
boost::optional< double > | outdoorAirFlowRateDuringHeatingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Outdoor Air Flow Rate". More... | |
bool | isOutdoorAirFlowRateDuringHeatingOperationAutosized () const |
boost::optional< double > | outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Outdoor Air Flow Rate". More... | |
bool | isOutdoorAirFlowRateWhenNoCoolingorHeatingisNeededAutosized () const |
HVACComponent | supplyAirFan () const |
HVACComponent | heatingCoil () const |
double | heatingConvergenceTolerance () const |
bool | isHeatingConvergenceToleranceDefaulted () const |
double | minimumOutdoorDryBulbTemperatureforCompressorOperation () const |
Not used as of EnergyPlus 8.8.0 and above. More... | |
bool | isMinimumOutdoorDryBulbTemperatureforCompressorOperationDefaulted () const |
HVACComponent | coolingCoil () const |
double | coolingConvergenceTolerance () const |
bool | isCoolingConvergenceToleranceDefaulted () const |
HVACComponent | supplementalHeatingCoil () const |
boost::optional< double > | maximumSupplyAirTemperaturefromSupplementalHeater () const |
bool | isMaximumSupplyAirTemperaturefromSupplementalHeaterAutosized () const |
double | maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation () const |
bool | isMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperationDefaulted () const |
std::string | fanPlacement () const |
bool | isFanPlacementDefaulted () const |
boost::optional< Schedule > | supplyAirFanOperatingModeSchedule () const |
Setters | |
bool | setAvailabilitySchedule (Schedule &schedule) |
bool | setOutdoorAirMixerObjectType (std::string outdoorAirMixerObjectType) |
bool | setOutdoorAirMixerName (std::string outdoorAirMixerName) |
bool | setSupplyAirFlowRateDuringCoolingOperation (double supplyAirFlowRateDuringCoolingOperation) |
void | autosizeSupplyAirFlowRateDuringCoolingOperation () |
bool | setSupplyAirFlowRateDuringHeatingOperation (double supplyAirFlowRateDuringHeatingOperation) |
void | autosizeSupplyAirFlowRateDuringHeatingOperation () |
bool | setSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded (double supplyAirFlowRateWhenNoCoolingorHeatingisNeeded) |
void | resetSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded () |
void | autosizeSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded () |
bool | setOutdoorAirFlowRateDuringCoolingOperation (double outdoorAirFlowRateDuringCoolingOperation) |
void | autosizeOutdoorAirFlowRateDuringCoolingOperation () |
bool | setOutdoorAirFlowRateDuringHeatingOperation (double outdoorAirFlowRateDuringHeatingOperation) |
void | autosizeOutdoorAirFlowRateDuringHeatingOperation () |
bool | setOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded (double outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded) |
void | resetOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () |
void | autosizeOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () |
bool | setSupplyAirFan (HVACComponent &hvacComponent) |
bool | setHeatingCoil (HVACComponent &hvacComponent) |
bool | setHeatingConvergenceTolerance (double heatingConvergenceTolerance) |
void | resetHeatingConvergenceTolerance () |
bool | setMinimumOutdoorDryBulbTemperatureforCompressorOperation (double minimumOutdoorDryBulbTemperatureforCompressorOperation) |
Not used as of EnergyPlus 8.8.0 and above. More... | |
void | resetMinimumOutdoorDryBulbTemperatureforCompressorOperation () |
bool | setCoolingCoil (HVACComponent &hvacComponent) |
bool | setCoolingConvergenceTolerance (double coolingConvergenceTolerance) |
void | resetCoolingConvergenceTolerance () |
bool | setSupplementalHeatingCoil (HVACComponent &hvacComponent) |
bool | setMaximumSupplyAirTemperaturefromSupplementalHeater (double maximumSupplyAirTemperaturefromSupplementalHeater) |
void | autosizeMaximumSupplyAirTemperaturefromSupplementalHeater () |
bool | setMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation (double maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation) |
void | resetMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation () |
bool | setFanPlacement (std::string fanPlacement) |
void | resetFanPlacement () |
bool | setSupplyAirFanOperatingModeSchedule (Schedule &schedule) |
Sets the supply air fan operating mode schedule. More... | |
void | resetSupplyAirFanOperatingModeSchedule () |
Other | |
boost::optional< double > | autosizedSupplyAirFlowRateDuringCoolingOperation () const |
boost::optional< double > | autosizedSupplyAirFlowRateDuringHeatingOperation () const |
boost::optional< double > | autosizedSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
boost::optional< double > | autosizedOutdoorAirFlowRateDuringCoolingOperation () const |
boost::optional< double > | autosizedOutdoorAirFlowRateDuringHeatingOperation () const |
boost::optional< double > | autosizedOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
boost::optional< double > | autosizedMaximumSupplyAirTemperaturefromSupplementalHeater () const |
Public Member Functions inherited from openstudio::model::ZoneHVACComponent | |
bool | addToNode (Node &node) |
Adds this ZoneHVACComponent to a node on an AirLoopHVAC object. More... | |
bool | addToThermalZone (ThermalZone &thermalZone) |
Adds this ZoneHVACComponent to the thermal zone while managing all node connections automatically. More... | |
boost::optional< ModelObject > | airInletModelObject () const |
Provided for backwards compatibility, use inletNode instead. More... | |
boost::optional< AirLoopHVAC > | airLoopHVAC () const |
Returns the AirLoopHVAC attached to this ZoneHVACComponent. More... | |
boost::optional< ModelObject > | airOutletModelObject () const |
Provided for backwards compatibility, use outletNode instead. More... | |
boost::optional< Node > | inletNode () const |
Returns the optional node connected to the inletPort(). More... | |
unsigned | inletPort () const |
Returns the inlet port. More... | |
boost::optional< Node > | outletNode () const |
Returns the optional node connected to the outletPort(). More... | |
unsigned | outletPort () const |
Returns the outlet port. More... | |
bool | removeFromAirLoopHVAC () |
If this ZoneHVACComponent is used as a supply component on an AirLoopHVAC system, then this method will detach this ZoneHVACComponent from the AirLoopHVAC system, otherwise this method does nothing. More... | |
void | removeFromThermalZone () |
Detaches this ZoneHVACComponent from the associated ThermalZone. More... | |
void | removeReturnPlenum () |
Remove any return plenum attached to this ZoneHVACComponent. More... | |
boost::optional < AirLoopHVACReturnPlenum > | returnPlenum () const |
bool | setReturnPlenum (const ThermalZone &plenumZone) |
Establish plenumZone as the return plenum for this ZoneHVACComponent. More... | |
virtual boost::optional < ThermalZone > | thermalZone () const |
Returns the optional ThermalZone that this ZoneHVACComponent is attached to. More... | |
virtual | ~ZoneHVACComponent () |
Public Member Functions inherited from openstudio::model::HVACComponent | |
bool | addToNode (Node &node) |
Adds this object to a new system node and returns a boolean indicating if the addition was successful. More... | |
bool | addToSplitter (Splitter &splitter) |
Adds this object to a splitter by creating a new branch. More... | |
boost::optional< AirLoopHVAC > | airLoopHVAC () const |
Returns the optional AirLoopHVAC object that the HVAC component is attached to. More... | |
boost::optional < AirLoopHVACOutdoorAirSystem > | airLoopHVACOutdoorAirSystem () const |
Returns the optional AirLoopHVACOutdoorAirSystem that the HVAC component is attached to. More... | |
void | applySizingValues () |
void | autosize () |
Returns the optional ModelObject connected to this object's port. More... | |
boost::optional< HVACComponent > | containingHVACComponent () const |
EnergyPlus unitary equipment and air terminals are typically composed of other HVAC components. More... | |
boost::optional < StraightComponent > | containingStraightComponent () const |
boost::optional < ZoneHVACComponent > | containingZoneHVACComponent () const |
Returns any ZoneHVACComponent that contains this HVACComponent. More... | |
void | disconnect () |
Removes all connections to other HVACComponent objects. More... | |
bool | isRemovable () const |
Indicates if the HVACComponent can be removed from the model. More... | |
boost::optional< Loop > | loop () const |
Returns the optional Loop object that the HVAC component is attached to. More... | |
boost::optional< PlantLoop > | plantLoop () const |
Returns the optional PlantLoop object that the HVAC component is attached to. More... | |
std::vector< IdfObject > | remove () |
Removes the HVACComponent from the model only if isRemovable() return true. More... | |
virtual | ~HVACComponent () |
Public Member Functions inherited from openstudio::model::ParentObject | |
std::vector< IddObjectType > | allowableChildTypes () const |
Returns a vector of allowable children types. More... | |
std::vector< ModelObject > | children () const |
Return direct child objects in the Model. More... | |
virtual | ~ParentObject () |
Public Member Functions inherited from openstudio::model::ModelObject | |
virtual | ~ModelObject () |
ModelObject | clone () const |
Creates a deep copy of this object, placing it in this object's model(). More... | |
ModelObject | clone (Model model) const |
Creates a deep copy of this object, placing it in model. More... | |
Component | createComponent () const |
Method for creating sharable Model snippets. More... | |
Model | model () const |
Returns the Model that contains this object. More... | |
boost::optional< ParentObject > | parent () const |
Return this object's parent in the hierarchy, if it has one. More... | |
std::vector< ResourceObject > | resources () const |
Get the resources directly used by this ModelObject. More... | |
template<typename T > | |
std::vector< T > | getModelObjectSources () const |
Get all objects of type T that point to this object. More... | |
template<typename T > | |
std::vector< T > | getModelObjectSources (IddObjectType iddObjectType) const |
Get all objects of type T that point to this object. More... | |
template<typename T > | |
boost::optional< T > | getModelObjectTarget (unsigned index) const |
Get the object of type T pointed to by this object from field index. More... | |
template<typename T > | |
std::vector< T > | getModelObjectTargets () const |
Get all objects of type T to which this object points. More... | |
const std::vector< std::string > & | outputVariableNames () const |
Get all output variables names that could be associated with this object. More... | |
std::vector< OutputVariable > | outputVariables () const |
Get all output variables associated with this object, must run simulation to generate data. More... | |
boost::optional < openstudio::TimeSeries > | getData (const OutputVariable &variable, const std::string &envPeriod) const |
Get data associated with this output variable and this object. More... | |
std::vector< LifeCycleCost > | lifeCycleCosts () const |
Returns the list of all LifeCycleCosts that refer to this object. More... | |
std::vector< IdfObject > | removeLifeCycleCosts () |
Removes all LifeCycleCosts that refer to this object. More... | |
IddObjectType | iddObjectType () const |
This is a virtual function that will tell you the type of iddObject you are dealing with. More... | |
AdditionalProperties | additionalProperties () const |
Returns this object's additional properties, constructing a new object if necessary. More... | |
bool | hasAdditionalProperties () const |
Returns true if this object has additional properties. More... | |
std::vector< IdfObject > | removeAdditionalProperties () |
Removes all additional properties that refer to this object. More... | |
bool | setParent (ParentObject &newParent) |
set the parent, child may have to call non-const methods on the parent More... | |
bool | operator< (const ModelObject &right) const |
bool | operator== (const ModelObject &other) const |
equality test More... | |
bool | operator!= (const ModelObject &other) const |
inequality test More... | |
std::vector< ScheduleTypeKey > | getScheduleTypeKeys (const Schedule &schedule) const |
Return the ScheduleTypeKeys indicating how schedule is used in this object. More... | |
boost::optional< double > | getAutosizedValue (std::string valueName, std::string unitString) const |
Gets the autosized component value from the sql file. More... | |
virtual std::vector < EMSActuatorNames > | emsActuatorNames () const |
Return the names of the available ems actuators. More... | |
virtual std::vector< std::string > | emsInternalVariableNames () const |
Return the names of the available ems internal variables. More... | |
boost::optional< ModelObject > | connectedObject (unsigned port) const |
boost::optional< unsigned > | connectedObjectPort (unsigned port) const |
Static Public Member Functions | |
static std::vector< std::string > | fanPlacementValues () |
static IddObjectType | iddObjectType () |
static std::vector< std::string > | outdoorAirMixerObjectTypeValues () |
static std::vector< std::string > | validFanPlacementValues () |
static std::vector< std::string > | validOutdoorAirMixerObjectTypeValues () |
Related Functions | |
(Note that these are not member functions.) | |
typedef boost::optional < ZoneHVACPackagedTerminalHeatPump > | OptionalZoneHVACPackagedTerminalHeatPump |
typedef std::vector < ZoneHVACPackagedTerminalHeatPump > | ZoneHVACPackagedTerminalHeatPumpVector |
Related Functions inherited from openstudio::model::ParentObject | |
std::vector< ModelObject > | getRecursiveChildren (const ParentObject &object, bool includeLifeCycleCostsAndAdditionalProperties=false, bool includeUsedResources=true) |
Returns object and all other objects accessible by calling children() on encountered ParentObjects . More... | |
std::vector< ModelObject > | getRecursiveChildrenAndResources (const ModelObject &object) |
Returns object and all other objects accessible by calling children() and resources() on encountered ModelObjects . More... | |
Related Functions inherited from openstudio::model::ModelObject | |
std::vector< ResourceObject > | getRecursiveResources (const ModelObject &object) |
Returns all ResourceObjects accessible by recursively calling .resources() starting from object. More... | |
Additional Inherited Members | |
Protected Types inherited from openstudio::model::ZoneHVACComponent | |
typedef detail::ZoneHVACComponent_Impl | ImplType |
Protected Types inherited from openstudio::model::HVACComponent | |
typedef detail::HVACComponent_Impl | ImplType |
Protected Types inherited from openstudio::model::ModelObject | |
typedef detail::ModelObject_Impl | ImplType |
Protected Member Functions inherited from openstudio::model::ZoneHVACComponent | |
virtual std::vector< ModelObject > | children () const override |
ZoneHVACComponent (IddObjectType type, const Model &model) | |
ZoneHVACComponent (std::shared_ptr< ImplType > impl) | |
Protected Member Functions inherited from openstudio::model::HVACComponent | |
HVACComponent (IddObjectType type, const Model &model) | |
HVACComponent (std::shared_ptr< ImplType > impl) | |
Protected Member Functions inherited from openstudio::model::ParentObject | |
ParentObject (IddObjectType type, const Model &model) | |
Constructs a new ParentObject object in the model. More... | |
Protected Member Functions inherited from openstudio::model::ModelObject | |
ModelObject (IddObjectType type, const Model &model, bool fastName=false) | |
ModelObject (std::shared_ptr< detail::ModelObject_Impl > impl) | |
ZoneHVACPackagedTerminalHeatPump is a ZoneHVACComponent that wraps the OpenStudio IDD object 'OS:ZoneHVAC:PackagedTerminalHeatPump'.
openstudio::model::ZoneHVACPackagedTerminalHeatPump::ZoneHVACPackagedTerminalHeatPump | ( | const Model & | model, |
Schedule & | availabilitySchedule, | ||
HVACComponent & | supplyAirFan, | ||
HVACComponent & | heatingCoil, | ||
HVACComponent & | coolingCoil, | ||
HVACComponent & | supplementalHeatingCoil | ||
) |
|
inlinevirtual |
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizedMaximumSupplyAirTemperaturefromSupplementalHeater | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizedOutdoorAirFlowRateDuringCoolingOperation | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizedOutdoorAirFlowRateDuringHeatingOperation | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizedOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizedSupplyAirFlowRateDuringCoolingOperation | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizedSupplyAirFlowRateDuringHeatingOperation | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizedSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizeMaximumSupplyAirTemperaturefromSupplementalHeater | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizeOutdoorAirFlowRateDuringCoolingOperation | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizeOutdoorAirFlowRateDuringHeatingOperation | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizeOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizeSupplyAirFlowRateDuringCoolingOperation | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizeSupplyAirFlowRateDuringHeatingOperation | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::autosizeSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) |
Schedule openstudio::model::ZoneHVACPackagedTerminalHeatPump::availabilitySchedule | ( | ) | const |
HVACComponent openstudio::model::ZoneHVACPackagedTerminalHeatPump::coolingCoil | ( | ) | const |
double openstudio::model::ZoneHVACPackagedTerminalHeatPump::coolingConvergenceTolerance | ( | ) | const |
std::string openstudio::model::ZoneHVACPackagedTerminalHeatPump::fanPlacement | ( | ) | const |
|
static |
HVACComponent openstudio::model::ZoneHVACPackagedTerminalHeatPump::heatingCoil | ( | ) | const |
double openstudio::model::ZoneHVACPackagedTerminalHeatPump::heatingConvergenceTolerance | ( | ) | const |
|
static |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::isCoolingConvergenceToleranceDefaulted | ( | ) | const |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::isFanPlacementDefaulted | ( | ) | const |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::isHeatingConvergenceToleranceDefaulted | ( | ) | const |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::isMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperationDefaulted | ( | ) | const |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::isMaximumSupplyAirTemperaturefromSupplementalHeaterAutosized | ( | ) | const |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::isMinimumOutdoorDryBulbTemperatureforCompressorOperationDefaulted | ( | ) | const |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::isOutdoorAirFlowRateDuringCoolingOperationAutosized | ( | ) | const |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::isOutdoorAirFlowRateDuringHeatingOperationAutosized | ( | ) | const |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::isOutdoorAirFlowRateWhenNoCoolingorHeatingisNeededAutosized | ( | ) | const |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::isSupplyAirFlowRateDuringCoolingOperationAutosized | ( | ) | const |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::isSupplyAirFlowRateDuringHeatingOperationAutosized | ( | ) | const |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::isSupplyAirFlowRateWhenNoCoolingorHeatingisNeededAutosized | ( | ) | const |
double openstudio::model::ZoneHVACPackagedTerminalHeatPump::maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::maximumSupplyAirTemperaturefromSupplementalHeater | ( | ) | const |
double openstudio::model::ZoneHVACPackagedTerminalHeatPump::minimumOutdoorDryBulbTemperatureforCompressorOperation | ( | ) | const |
Not used as of EnergyPlus 8.8.0 and above.
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::outdoorAirFlowRateDuringCoolingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Outdoor Air Flow Rate".
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::outdoorAirFlowRateDuringHeatingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Outdoor Air Flow Rate".
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Outdoor Air Flow Rate".
std::string openstudio::model::ZoneHVACPackagedTerminalHeatPump::outdoorAirMixerName | ( | ) | const |
std::string openstudio::model::ZoneHVACPackagedTerminalHeatPump::outdoorAirMixerObjectType | ( | ) | const |
|
static |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::resetCoolingConvergenceTolerance | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::resetFanPlacement | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::resetHeatingConvergenceTolerance | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::resetMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::resetMinimumOutdoorDryBulbTemperatureforCompressorOperation | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::resetOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::resetSupplyAirFanOperatingModeSchedule | ( | ) |
void openstudio::model::ZoneHVACPackagedTerminalHeatPump::resetSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setAvailabilitySchedule | ( | Schedule & | schedule | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setCoolingCoil | ( | HVACComponent & | hvacComponent | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setCoolingConvergenceTolerance | ( | double | coolingConvergenceTolerance | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setFanPlacement | ( | std::string | fanPlacement | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setHeatingCoil | ( | HVACComponent & | hvacComponent | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setHeatingConvergenceTolerance | ( | double | heatingConvergenceTolerance | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ( | double | maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setMaximumSupplyAirTemperaturefromSupplementalHeater | ( | double | maximumSupplyAirTemperaturefromSupplementalHeater | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setMinimumOutdoorDryBulbTemperatureforCompressorOperation | ( | double | minimumOutdoorDryBulbTemperatureforCompressorOperation | ) |
Not used as of EnergyPlus 8.8.0 and above.
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setOutdoorAirFlowRateDuringCoolingOperation | ( | double | outdoorAirFlowRateDuringCoolingOperation | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setOutdoorAirFlowRateDuringHeatingOperation | ( | double | outdoorAirFlowRateDuringHeatingOperation | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | double | outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setOutdoorAirMixerName | ( | std::string | outdoorAirMixerName | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setOutdoorAirMixerObjectType | ( | std::string | outdoorAirMixerObjectType | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setSupplementalHeatingCoil | ( | HVACComponent & | hvacComponent | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setSupplyAirFan | ( | HVACComponent & | hvacComponent | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setSupplyAirFanOperatingModeSchedule | ( | Schedule & | schedule | ) |
Sets the supply air fan operating mode schedule.
Values of zero indicate that the fan cycles on and off with the active (heating or cooling) coil. Other values operate the fan continuously.
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setSupplyAirFlowRateDuringCoolingOperation | ( | double | supplyAirFlowRateDuringCoolingOperation | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setSupplyAirFlowRateDuringHeatingOperation | ( | double | supplyAirFlowRateDuringHeatingOperation | ) |
bool openstudio::model::ZoneHVACPackagedTerminalHeatPump::setSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | double | supplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ) |
HVACComponent openstudio::model::ZoneHVACPackagedTerminalHeatPump::supplementalHeatingCoil | ( | ) | const |
HVACComponent openstudio::model::ZoneHVACPackagedTerminalHeatPump::supplyAirFan | ( | ) | const |
boost::optional<Schedule> openstudio::model::ZoneHVACPackagedTerminalHeatPump::supplyAirFanOperatingModeSchedule | ( | ) | const |
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::supplyAirFlowRateDuringCoolingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Supply Air Flow Rate".
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::supplyAirFlowRateDuringHeatingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Supply Air Flow Rate".
boost::optional<double> openstudio::model::ZoneHVACPackagedTerminalHeatPump::supplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Supply Air Flow Rate".
|
static |
|
static |
|
related |
|