| AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass (const Model &model, const HVACComponent &fan, const HVACComponent &coolingCoil, const HVACComponent &heatingCoil) |
|
virtual | ~AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass ()=default |
|
| AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass (const AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass &other)=default |
|
| AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass (AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass &&other)=default |
|
AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass & | operator= (const AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass &)=default |
|
AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass & | operator= (AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass &&)=default |
|
|
boost::optional< Schedule > | availabilitySchedule () const |
|
boost::optional< double > | systemAirFlowRateDuringCoolingOperation () const |
| In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Supply Air Flow Rate". More...
|
|
bool | isSystemAirFlowRateDuringCoolingOperationAutosized () const |
|
boost::optional< double > | systemAirFlowRateDuringHeatingOperation () const |
| In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Supply Air Flow Rate". More...
|
|
bool | isSystemAirFlowRateDuringHeatingOperationAutosized () const |
|
boost::optional< double > | systemAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
| In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Supply Air Flow Rate". More...
|
|
bool | isSystemAirFlowRateWhenNoCoolingorHeatingisNeededAutosized () const |
|
boost::optional< double > | outdoorAirFlowRateDuringCoolingOperation () const |
| In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Outdoor Air Flow Rate". More...
|
|
bool | isOutdoorAirFlowRateDuringCoolingOperationAutosized () const |
|
boost::optional< double > | outdoorAirFlowRateDuringHeatingOperation () const |
| In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Outdoor Air Flow Rate". More...
|
|
bool | isOutdoorAirFlowRateDuringHeatingOperationAutosized () const |
|
boost::optional< double > | outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
| In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Outdoor Air Flow Rate". More...
|
|
bool | isOutdoorAirFlowRateWhenNoCoolingorHeatingisNeededAutosized () const |
|
boost::optional< Schedule > | outdoorAirFlowRateMultiplierSchedule () const |
|
HVACComponent | supplyAirFan () const |
|
std::string | supplyAirFanPlacement () const |
|
boost::optional< Schedule > | supplyAirFanOperatingModeSchedule () const |
|
HVACComponent | coolingCoil () const |
|
HVACComponent | heatingCoil () const |
|
std::string | priorityControlMode () const |
|
double | minimumOutletAirTemperatureDuringCoolingOperation () const |
|
double | maximumOutletAirTemperatureDuringHeatingOperation () const |
|
std::string | dehumidificationControlType () const |
|
double | minimumRuntimeBeforeOperatingModeChange () const |
|
unsigned | plenumorMixerAirPort () const |
|
Node | plenumorMixerNode () const |
| This Node always exists for connecting "Plenum or Mixer Inlet Node", it will be translated only if actually connected to an AirLoopHVAC:ReturnPlenum or an AirLoopHVAC:ZoneMixer. More...
|
|
boost::optional< Mixer > | plenumorMixer () const |
| Convenience method to get the optional linked Mixer object (AirLoopHVAC:ReturnPlenum or AirLoopHVAC:ZoneMixer) More...
|
|
|
bool | setAvailabilitySchedule (Schedule &schedule) |
|
void | resetAvailabilitySchedule () |
|
bool | setSystemAirFlowRateDuringCoolingOperation (double systemAirFlowRateDuringCoolingOperation) |
|
void | autosizeSystemAirFlowRateDuringCoolingOperation () |
|
bool | setSystemAirFlowRateDuringHeatingOperation (double systemAirFlowRateDuringHeatingOperation) |
|
void | autosizeSystemAirFlowRateDuringHeatingOperation () |
|
bool | setSystemAirFlowRateWhenNoCoolingorHeatingisNeeded (double systemAirFlowRateWhenNoCoolingorHeatingisNeeded) |
|
void | autosizeSystemAirFlowRateWhenNoCoolingorHeatingisNeeded () |
|
bool | setOutdoorAirFlowRateDuringCoolingOperation (double outdoorAirFlowRateDuringCoolingOperation) |
|
void | autosizeOutdoorAirFlowRateDuringCoolingOperation () |
|
bool | setOutdoorAirFlowRateDuringHeatingOperation (double outdoorAirFlowRateDuringHeatingOperation) |
|
void | autosizeOutdoorAirFlowRateDuringHeatingOperation () |
|
bool | setOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded (double outdoorAirFlowRateWhenNoCoolingorHeatingisNeeded) |
|
void | autosizeOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () |
|
bool | setOutdoorAirFlowRateMultiplierSchedule (Schedule &outdoorAirFlowRateMultiplierSchedule) |
|
void | resetOutdoorAirFlowRateMultiplierSchedule () |
|
bool | setSupplyAirFan (const HVACComponent &fansCVandOnOff) |
|
bool | setSupplyAirFanPlacement (const std::string &supplyAirFanPlacement) |
|
bool | setSupplyAirFanOperatingModeSchedule (Schedule &schedule) |
|
void | resetSupplyAirFanOperatingModeSchedule () |
|
bool | setCoolingCoil (const HVACComponent &coolingCoilName) |
|
bool | setHeatingCoil (const HVACComponent &heatingCoilName) |
|
bool | setPriorityControlMode (const std::string &priorityControlMode) |
|
bool | setMinimumOutletAirTemperatureDuringCoolingOperation (double minimumOutletAirTemperatureDuringCoolingOperation) |
|
bool | setMaximumOutletAirTemperatureDuringHeatingOperation (double maximumOutletAirTemperatureDuringHeatingOperation) |
|
bool | setDehumidificationControlType (const std::string &dehumidificationControlType) |
|
bool | setMinimumRuntimeBeforeOperatingModeChange (double runtime) |
|
bool | setPlenumorMixer (const Mixer &returnPathComponent) |
| Connect the bypass air duct to an AirLoopHVAC:ReturnPlenum or an AirLoopHVAC:ZoneMixer that must be on the same AirLoopHVAC as this Unitary System. More...
|
|
void | resetPlenumorMixer () |
|
boost::optional< double > | autosizedSystemAirFlowRateDuringCoolingOperation () const |
|
boost::optional< double > | autosizedSystemAirFlowRateDuringHeatingOperation () const |
|
boost::optional< double > | autosizedSystemAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
|
boost::optional< double > | autosizedOutdoorAirFlowRateDuringCoolingOperation () const |
|
boost::optional< double > | autosizedOutdoorAirFlowRateDuringHeatingOperation () const |
|
boost::optional< double > | autosizedOutdoorAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
|
bool | addToNode (Node &node) |
|
boost::optional< AirLoopHVAC > | airLoopHVAC () const |
| Returns the optional AirLoopHVAC object that this AirToAirComponent is attached to. More...
|
|
ModelObject | clone (Model model) const |
|
void | disconnect () |
|
boost::optional< ModelObject > | inletModelObject () const |
| Returns the optional ModelObject connected to the inlet port. More...
|
|
unsigned | inletPort () const |
| Returns the inlet port. More...
|
|
StraightComponent & | operator= (const StraightComponent &)=default |
|
StraightComponent & | operator= (StraightComponent &&)=default |
|
boost::optional< ModelObject > | outletModelObject () const |
| Returns the optional ModelObject connected to the outlet port. More...
|
|
unsigned | outletPort () const |
| Returns the outlet port. More...
|
|
std::vector
< openstudio::IdfObject > | remove () |
|
bool | removeFromLoop () |
|
| StraightComponent (IddObjectType type, const Model &model) |
|
| StraightComponent (const StraightComponent &other)=default |
|
| StraightComponent (StraightComponent &&other)=default |
|
virtual | ~StraightComponent ()=default |
|
bool | addToNode (Node &node) |
| Adds this object to a new system node and returns a boolean indicating if the addition was successful. More...
|
|
bool | addToSplitter (Splitter &splitter) |
| Adds this object to a splitter by creating a new branch. More...
|
|
boost::optional< AirLoopHVAC > | airLoopHVAC () const |
| Returns the optional AirLoopHVAC object that the HVAC component is attached to. More...
|
|
boost::optional
< AirLoopHVACOutdoorAirSystem > | airLoopHVACOutdoorAirSystem () const |
| Returns the optional AirLoopHVACOutdoorAirSystem that the HVAC component is attached to. More...
|
|
std::vector< AppGFuelType > | appGHeatingFuelTypes () const |
|
void | applySizingValues () |
|
void | autosize () |
| Returns the optional ModelObject connected to this object's port. More...
|
|
ComponentType | componentType () const |
|
boost::optional< HVACComponent > | containingHVACComponent () const |
| EnergyPlus unitary equipment and air terminals are typically composed of other HVAC components. More...
|
|
boost::optional
< StraightComponent > | containingStraightComponent () const |
|
boost::optional
< ZoneHVACComponent > | containingZoneHVACComponent () const |
| Returns any ZoneHVACComponent that contains this HVACComponent. More...
|
|
std::vector< FuelType > | coolingFuelTypes () const |
|
void | disconnect () |
| Removes all connections to other HVACComponent objects. More...
|
|
std::vector< FuelType > | heatingFuelTypes () const |
|
| HVACComponent (const HVACComponent &other)=default |
|
| HVACComponent (HVACComponent &&other)=default |
|
bool | isRemovable () const |
| Indicates if the HVACComponent can be removed from the model. More...
|
|
boost::optional< Loop > | loop () const |
| Returns the optional Loop object that the HVAC component is attached to. More...
|
|
HVACComponent & | operator= (const HVACComponent &)=default |
|
HVACComponent & | operator= (HVACComponent &&)=default |
|
boost::optional< PlantLoop > | plantLoop () const |
| Returns the optional PlantLoop object that the HVAC component is attached to. More...
|
|
std::vector< IdfObject > | remove () |
| Removes the HVACComponent from the model only if isRemovable() return true. More...
|
|
virtual | ~HVACComponent ()=default |
|
std::vector< IddObjectType > | allowableChildTypes () const |
| Returns a vector of allowable children types. More...
|
|
std::vector< ModelObject > | children () const |
| Return direct child objects in the Model. More...
|
|
ParentObject & | operator= (const ParentObject &)=default |
|
ParentObject & | operator= (ParentObject &&)=default |
|
| ParentObject (const ParentObject &other)=default |
|
| ParentObject (ParentObject &&other)=default |
|
virtual | ~ParentObject ()=default |
|
virtual | ~ModelObject ()=default |
|
| ModelObject (const ModelObject &other)=default |
|
| ModelObject (ModelObject &&other)=default |
|
ModelObject & | operator= (const ModelObject &)=default |
|
ModelObject & | operator= (ModelObject &&)=default |
|
ModelObject | clone () const |
| Creates a deep copy of this object, placing it in this object's model(). More...
|
|
ModelObject | clone (Model model) const |
| Creates a deep copy of this object, placing it in model. More...
|
|
Component | createComponent () const |
| Method for creating sharable Model snippets. More...
|
|
Model | model () const |
| Returns the Model that contains this object. More...
|
|
boost::optional< ParentObject > | parent () const |
| Return this object's parent in the hierarchy, if it has one. More...
|
|
std::vector< ResourceObject > | resources () const |
| Get the resources directly used by this ModelObject. More...
|
|
template<typename T > |
std::vector< T > | getModelObjectSources () const |
| Get all objects of type T that point to this object. More...
|
|
template<typename T > |
std::vector< T > | getModelObjectSources (IddObjectType iddObjectType) const |
| Get all objects of type T that point to this object. More...
|
|
template<typename T > |
boost::optional< T > | getModelObjectTarget (unsigned index) const |
| Get the object of type T pointed to by this object from field index. More...
|
|
template<typename T > |
std::vector< T > | getModelObjectTargets () const |
| Get all objects of type T to which this object points. More...
|
|
const std::vector< std::string > & | outputVariableNames () const |
| Get all output variables names that could be associated with this object. More...
|
|
std::vector< OutputVariable > | outputVariables () const |
| Get all output variables associated with this object, must run simulation to generate data. More...
|
|
boost::optional
< openstudio::TimeSeries > | getData (const OutputVariable &variable, const std::string &envPeriod) const |
| Get data associated with this output variable and this object. More...
|
|
std::vector< LifeCycleCost > | lifeCycleCosts () const |
| Returns the list of all LifeCycleCosts that refer to this object. More...
|
|
std::vector< IdfObject > | removeLifeCycleCosts () |
| Removes all LifeCycleCosts that refer to this object. More...
|
|
IddObjectType | iddObjectType () const |
| This is a virtual function that will tell you the type of iddObject you are dealing with. More...
|
|
AdditionalProperties | additionalProperties () const |
| Returns this object's additional properties, constructing a new object if necessary. More...
|
|
bool | hasAdditionalProperties () const |
| Returns true if this object has additional properties. More...
|
|
std::vector< IdfObject > | removeAdditionalProperties () |
| Removes all additional properties that refer to this object. More...
|
|
boost::optional< std::string > | cadObjectId () const |
|
bool | setCADObjectId (const std::string &cadObjectId) |
|
boost::optional< std::string > | gbXMLId () const |
|
bool | setGBXMLId (const std::string &gbXMLId) |
|
boost::optional< std::string > | displayName () const |
|
bool | setDisplayName (const std::string &displayName) |
|
bool | setParent (ParentObject &newParent) |
| set the parent, child may have to call non-const methods on the parent More...
|
|
bool | operator< (const ModelObject &right) const |
|
bool | operator== (const ModelObject &other) const |
| equality test More...
|
|
bool | operator!= (const ModelObject &other) const |
| inequality test More...
|
|
std::vector< ScheduleTypeKey > | getScheduleTypeKeys (const Schedule &schedule) const |
| Return the ScheduleTypeKeys indicating how schedule is used in this object. More...
|
|
boost::optional< double > | getAutosizedValue (const std::string &valueName, const std::string &units) const |
| Gets the autosized component value from the sql file. More...
|
|
virtual std::vector
< EMSActuatorNames > | emsActuatorNames () const |
| Return the names of the available ems actuators. More...
|
|
virtual std::vector< std::string > | emsInternalVariableNames () const |
| Return the names of the available ems internal variables. More...
|
|
boost::optional< ModelObject > | connectedObject (unsigned port) const |
|
boost::optional< unsigned > | connectedObjectPort (unsigned port) const |
|