#include <AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed.hpp>
Public Member Functions | |
Constructors and Destructors | |
AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed (const Model &model, const HVACComponent &fan, const HVACComponent &heatingCoil, const HVACComponent &coolingCoil, const HVACComponent &supplementalHeatingCoil) | |
virtual | ~AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed ()=default |
AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed (const AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed &other)=default | |
AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed (AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed &&other)=default | |
AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed & | operator= (const AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed &)=default |
AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed & | operator= (AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed &&)=default |
Getters | |
boost::optional< Schedule > | availabilitySchedule () const |
boost::optional< ThermalZone > | controllingZoneorThermostatLocation () const |
HVACComponent | supplyAirFan () const |
std::string | supplyAirFanPlacement () const |
Schedule | supplyAirFanOperatingModeSchedule () const |
HVACComponent | heatingCoil () const |
double | minimumOutdoorDryBulbTemperatureforCompressorOperation () const |
HVACComponent | coolingCoil () const |
HVACComponent | supplementalHeatingCoil () const |
boost::optional< double > | maximumSupplyAirTemperaturefromSupplementalHeater () const |
bool | isMaximumSupplyAirTemperaturefromSupplementalHeaterAutosized () const |
double | maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation () const |
double | auxiliaryOnCycleElectricPower () const |
double | auxiliaryOffCycleElectricPower () const |
double | designHeatRecoveryWaterFlowRate () const |
double | maximumTemperatureforHeatRecovery () const |
boost::optional< double > | supplyAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Supply Air Flow Rate". More... | |
bool | isSupplyAirFlowRateWhenNoCoolingorHeatingisNeededAutosized () const |
int | numberofSpeedsforHeating () const |
int | numberofSpeedsforCooling () const |
boost::optional< double > | speed1SupplyAirFlowRateDuringHeatingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Speed 1 Supply Air Flow Rate". More... | |
bool | isSpeed1SupplyAirFlowRateDuringHeatingOperationAutosized () const |
boost::optional< double > | speed2SupplyAirFlowRateDuringHeatingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Speed 2 Supply Air Flow Rate". More... | |
bool | isSpeed2SupplyAirFlowRateDuringHeatingOperationAutosized () const |
boost::optional< double > | speed3SupplyAirFlowRateDuringHeatingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Speed 3 Supply Air Flow Rate". More... | |
bool | isSpeed3SupplyAirFlowRateDuringHeatingOperationAutosized () const |
boost::optional< double > | speed4SupplyAirFlowRateDuringHeatingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Speed 4 Supply Air Flow Rate". More... | |
bool | isSpeed4SupplyAirFlowRateDuringHeatingOperationAutosized () const |
boost::optional< double > | speed1SupplyAirFlowRateDuringCoolingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Speed 1 Supply Air Flow Rate". More... | |
bool | isSpeed1SupplyAirFlowRateDuringCoolingOperationAutosized () const |
boost::optional< double > | speed2SupplyAirFlowRateDuringCoolingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Speed 2 Supply Air Flow Rate". More... | |
bool | isSpeed2SupplyAirFlowRateDuringCoolingOperationAutosized () const |
boost::optional< double > | speed3SupplyAirFlowRateDuringCoolingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Speed 3 Supply Air Flow Rate". More... | |
bool | isSpeed3SupplyAirFlowRateDuringCoolingOperationAutosized () const |
boost::optional< double > | speed4SupplyAirFlowRateDuringCoolingOperation () const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Speed 4 Supply Air Flow Rate". More... | |
bool | isSpeed4SupplyAirFlowRateDuringCoolingOperationAutosized () const |
Setters | |
bool | setAvailabilitySchedule (Schedule &schedule) |
void | resetAvailabilitySchedule () |
bool | setControllingZoneorThermostatLocation (const ThermalZone &thermalZone) |
void | resetControllingZoneorThermostatLocation () |
bool | setSupplyAirFan (const HVACComponent &fan) |
bool | setSupplyAirFanPlacement (const std::string &supplyAirFanPlacement) |
bool | setSupplyAirFanOperatingModeSchedule (Schedule &schedule) |
bool | setHeatingCoil (const HVACComponent &coil) |
bool | setMinimumOutdoorDryBulbTemperatureforCompressorOperation (double minimumOutdoorDryBulbTemperatureforCompressorOperation) |
bool | setCoolingCoil (const HVACComponent &coil) |
bool | setSupplementalHeatingCoil (const HVACComponent &coil) |
bool | setMaximumSupplyAirTemperaturefromSupplementalHeater (double maximumSupplyAirTemperaturefromSupplementalHeater) |
void | autosizeMaximumSupplyAirTemperaturefromSupplementalHeater () |
bool | setMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation (double maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation) |
bool | setAuxiliaryOnCycleElectricPower (double auxiliaryOnCycleElectricPower) |
bool | setAuxiliaryOffCycleElectricPower (double auxiliaryOffCycleElectricPower) |
bool | setDesignHeatRecoveryWaterFlowRate (double designHeatRecoveryWaterFlowRate) |
bool | setMaximumTemperatureforHeatRecovery (double maximumTemperatureforHeatRecovery) |
bool | setSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded (double supplyAirFlowRateWhenNoCoolingorHeatingisNeeded) |
void | autosizeSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded () |
bool | setNumberofSpeedsforHeating (int numberofSpeedsforHeating) |
bool | setNumberofSpeedsforCooling (int numberofSpeedsforCooling) |
bool | setSpeed1SupplyAirFlowRateDuringHeatingOperation (double speed1SupplyAirFlowRateDuringHeatingOperation) |
void | autosizeSpeed1SupplyAirFlowRateDuringHeatingOperation () |
bool | setSpeed2SupplyAirFlowRateDuringHeatingOperation (double speed2SupplyAirFlowRateDuringHeatingOperation) |
void | autosizeSpeed2SupplyAirFlowRateDuringHeatingOperation () |
bool | setSpeed3SupplyAirFlowRateDuringHeatingOperation (double speed3SupplyAirFlowRateDuringHeatingOperation) |
void | autosizeSpeed3SupplyAirFlowRateDuringHeatingOperation () |
bool | setSpeed4SupplyAirFlowRateDuringHeatingOperation (double speed4SupplyAirFlowRateDuringHeatingOperation) |
void | autosizeSpeed4SupplyAirFlowRateDuringHeatingOperation () |
bool | setSpeed1SupplyAirFlowRateDuringCoolingOperation (double speed1SupplyAirFlowRateDuringCoolingOperation) |
void | autosizeSpeed1SupplyAirFlowRateDuringCoolingOperation () |
bool | setSpeed2SupplyAirFlowRateDuringCoolingOperation (double speed2SupplyAirFlowRateDuringCoolingOperation) |
void | autosizeSpeed2SupplyAirFlowRateDuringCoolingOperation () |
bool | setSpeed3SupplyAirFlowRateDuringCoolingOperation (double speed3SupplyAirFlowRateDuringCoolingOperation) |
void | autosizeSpeed3SupplyAirFlowRateDuringCoolingOperation () |
bool | setSpeed4SupplyAirFlowRateDuringCoolingOperation (double speed4SupplyAirFlowRateDuringCoolingOperation) |
void | autosizeSpeed4SupplyAirFlowRateDuringCoolingOperation () |
Other | |
boost::optional< double > | autosizedMaximumSupplyAirTemperaturefromSupplementalHeater () const |
boost::optional< double > | autosizedSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded () const |
boost::optional< double > | autosizedSpeed1SupplyAirFlowRateDuringHeatingOperation () const |
boost::optional< double > | autosizedSpeed2SupplyAirFlowRateDuringHeatingOperation () const |
boost::optional< double > | autosizedSpeed3SupplyAirFlowRateDuringHeatingOperation () const |
boost::optional< double > | autosizedSpeed4SupplyAirFlowRateDuringHeatingOperation () const |
boost::optional< double > | autosizedSpeed1SupplyAirFlowRateDuringCoolingOperation () const |
boost::optional< double > | autosizedSpeed2SupplyAirFlowRateDuringCoolingOperation () const |
boost::optional< double > | autosizedSpeed3SupplyAirFlowRateDuringCoolingOperation () const |
boost::optional< double > | autosizedSpeed4SupplyAirFlowRateDuringCoolingOperation () const |
Public Member Functions inherited from openstudio::model::StraightComponent | |
bool | addToNode (Node &node) |
boost::optional< AirLoopHVAC > | airLoopHVAC () const |
Returns the optional AirLoopHVAC object that this AirToAirComponent is attached to. More... | |
ModelObject | clone (Model model) const |
void | disconnect () |
boost::optional< ModelObject > | inletModelObject () const |
Returns the optional ModelObject connected to the inlet port. More... | |
unsigned | inletPort () const |
Returns the inlet port. More... | |
StraightComponent & | operator= (const StraightComponent &)=default |
StraightComponent & | operator= (StraightComponent &&)=default |
boost::optional< ModelObject > | outletModelObject () const |
Returns the optional ModelObject connected to the outlet port. More... | |
unsigned | outletPort () const |
Returns the outlet port. More... | |
std::vector < openstudio::IdfObject > | remove () |
bool | removeFromLoop () |
StraightComponent (IddObjectType type, const Model &model) | |
StraightComponent (const StraightComponent &other)=default | |
StraightComponent (StraightComponent &&other)=default | |
virtual | ~StraightComponent ()=default |
Public Member Functions inherited from openstudio::model::HVACComponent | |
bool | addToNode (Node &node) |
Adds this object to a new system node and returns a boolean indicating if the addition was successful. More... | |
bool | addToSplitter (Splitter &splitter) |
Adds this object to a splitter by creating a new branch. More... | |
boost::optional< AirLoopHVAC > | airLoopHVAC () const |
Returns the optional AirLoopHVAC object that the HVAC component is attached to. More... | |
boost::optional < AirLoopHVACOutdoorAirSystem > | airLoopHVACOutdoorAirSystem () const |
Returns the optional AirLoopHVACOutdoorAirSystem that the HVAC component is attached to. More... | |
std::vector< AppGFuelType > | appGHeatingFuelTypes () const |
void | applySizingValues () |
void | autosize () |
Returns the optional ModelObject connected to this object's port. More... | |
ComponentType | componentType () const |
boost::optional< HVACComponent > | containingHVACComponent () const |
EnergyPlus unitary equipment and air terminals are typically composed of other HVAC components. More... | |
boost::optional < StraightComponent > | containingStraightComponent () const |
boost::optional < ZoneHVACComponent > | containingZoneHVACComponent () const |
Returns any ZoneHVACComponent that contains this HVACComponent. More... | |
std::vector< FuelType > | coolingFuelTypes () const |
void | disconnect () |
Removes all connections to other HVACComponent objects. More... | |
std::vector< FuelType > | heatingFuelTypes () const |
HVACComponent (const HVACComponent &other)=default | |
HVACComponent (HVACComponent &&other)=default | |
bool | isRemovable () const |
Indicates if the HVACComponent can be removed from the model. More... | |
boost::optional< Loop > | loop () const |
Returns the optional Loop object that the HVAC component is attached to. More... | |
HVACComponent & | operator= (const HVACComponent &)=default |
HVACComponent & | operator= (HVACComponent &&)=default |
boost::optional< PlantLoop > | plantLoop () const |
Returns the optional PlantLoop object that the HVAC component is attached to. More... | |
std::vector< IdfObject > | remove () |
Removes the HVACComponent from the model only if isRemovable() return true. More... | |
virtual | ~HVACComponent ()=default |
Public Member Functions inherited from openstudio::model::ParentObject | |
std::vector< IddObjectType > | allowableChildTypes () const |
Returns a vector of allowable children types. More... | |
std::vector< ModelObject > | children () const |
Return direct child objects in the Model. More... | |
ParentObject & | operator= (const ParentObject &)=default |
ParentObject & | operator= (ParentObject &&)=default |
ParentObject (const ParentObject &other)=default | |
ParentObject (ParentObject &&other)=default | |
virtual | ~ParentObject ()=default |
Public Member Functions inherited from openstudio::model::ModelObject | |
virtual | ~ModelObject ()=default |
ModelObject (const ModelObject &other)=default | |
ModelObject (ModelObject &&other)=default | |
ModelObject & | operator= (const ModelObject &)=default |
ModelObject & | operator= (ModelObject &&)=default |
ModelObject | clone () const |
Creates a deep copy of this object, placing it in this object's model(). More... | |
ModelObject | clone (Model model) const |
Creates a deep copy of this object, placing it in model. More... | |
Component | createComponent () const |
Method for creating sharable Model snippets. More... | |
Model | model () const |
Returns the Model that contains this object. More... | |
boost::optional< ParentObject > | parent () const |
Return this object's parent in the hierarchy, if it has one. More... | |
std::vector< ResourceObject > | resources () const |
Get the resources directly used by this ModelObject. More... | |
template<typename T > | |
std::vector< T > | getModelObjectSources () const |
Get all objects of type T that point to this object. More... | |
template<typename T > | |
std::vector< T > | getModelObjectSources (IddObjectType iddObjectType) const |
Get all objects of type T that point to this object. More... | |
template<typename T > | |
boost::optional< T > | getModelObjectTarget (unsigned index) const |
Get the object of type T pointed to by this object from field index. More... | |
template<typename T > | |
std::vector< T > | getModelObjectTargets () const |
Get all objects of type T to which this object points. More... | |
const std::vector< std::string > & | outputVariableNames () const |
Get all output variables names that could be associated with this object. More... | |
std::vector< OutputVariable > | outputVariables () const |
Get all output variables associated with this object, must run simulation to generate data. More... | |
boost::optional < openstudio::TimeSeries > | getData (const OutputVariable &variable, const std::string &envPeriod) const |
Get data associated with this output variable and this object. More... | |
std::vector< LifeCycleCost > | lifeCycleCosts () const |
Returns the list of all LifeCycleCosts that refer to this object. More... | |
std::vector< IdfObject > | removeLifeCycleCosts () |
Removes all LifeCycleCosts that refer to this object. More... | |
IddObjectType | iddObjectType () const |
This is a virtual function that will tell you the type of iddObject you are dealing with. More... | |
AdditionalProperties | additionalProperties () const |
Returns this object's additional properties, constructing a new object if necessary. More... | |
bool | hasAdditionalProperties () const |
Returns true if this object has additional properties. More... | |
std::vector< IdfObject > | removeAdditionalProperties () |
Removes all additional properties that refer to this object. More... | |
boost::optional< std::string > | cadObjectId () const |
bool | setCADObjectId (const std::string &cadObjectId) |
boost::optional< std::string > | gbXMLId () const |
bool | setGBXMLId (const std::string &gbXMLId) |
boost::optional< std::string > | displayName () const |
bool | setDisplayName (const std::string &displayName) |
bool | setParent (ParentObject &newParent) |
set the parent, child may have to call non-const methods on the parent More... | |
bool | operator< (const ModelObject &right) const |
bool | operator== (const ModelObject &other) const |
equality test More... | |
bool | operator!= (const ModelObject &other) const |
inequality test More... | |
std::vector< ScheduleTypeKey > | getScheduleTypeKeys (const Schedule &schedule) const |
Return the ScheduleTypeKeys indicating how schedule is used in this object. More... | |
boost::optional< double > | getAutosizedValue (const std::string &valueName, const std::string &units) const |
Gets the autosized component value from the sql file. More... | |
virtual std::vector < EMSActuatorNames > | emsActuatorNames () const |
Return the names of the available ems actuators. More... | |
virtual std::vector< std::string > | emsInternalVariableNames () const |
Return the names of the available ems internal variables. More... | |
boost::optional< ModelObject > | connectedObject (unsigned port) const |
boost::optional< unsigned > | connectedObjectPort (unsigned port) const |
Static Public Member Functions | |
static IddObjectType | iddObjectType () |
static std::vector< std::string > | supplyAirFanPlacementValues () |
Related Functions | |
(Note that these are not member functions.) | |
using | AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeedVector = std::vector< AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed > |
using | OptionalAirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed = boost::optional< AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed > |
Related Functions inherited from openstudio::model::ParentObject | |
std::vector< ModelObject > | getRecursiveChildren (const ParentObject &object, bool includeLifeCycleCostsAndAdditionalProperties=false, bool includeUsedResources=true) |
Returns object and all other objects accessible by calling children() on encountered ParentObjects . More... | |
std::vector< ModelObject > | getRecursiveChildrenAndResources (const ModelObject &object) |
Returns object and all other objects accessible by calling children() and resources() on encountered ModelObjects . More... | |
Related Functions inherited from openstudio::model::ModelObject | |
std::vector< ResourceObject > | getRecursiveResources (const ModelObject &object) |
Returns all ResourceObjects accessible by recursively calling .resources() starting from object. More... | |
Additional Inherited Members | |
Protected Types inherited from openstudio::model::HVACComponent | |
using | ImplType = detail::HVACComponent_Impl |
Protected Types inherited from openstudio::model::ModelObject | |
using | ImplType = detail::ModelObject_Impl |
Protected Member Functions inherited from openstudio::model::HVACComponent | |
virtual std::vector< ModelObject > | children () const |
HVACComponent (IddObjectType type, const Model &model) | |
HVACComponent (std::shared_ptr< ImplType > impl) | |
Protected Member Functions inherited from openstudio::model::ParentObject | |
ParentObject (IddObjectType type, const Model &model) | |
Constructs a new ParentObject object in the model. More... | |
Protected Member Functions inherited from openstudio::model::ModelObject | |
ModelObject (IddObjectType type, const Model &model, bool fastName=false) | |
ModelObject (std::shared_ptr< detail::ModelObject_Impl > impl) | |
AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed is a StraightComponent that wraps the OpenStudio IDD object 'OS:AirLoopHVAC:UnitaryHeatPump:AirToAir:MultiSpeed'.
|
explicit |
|
virtualdefault |
|
default |
|
default |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizedMaximumSupplyAirTemperaturefromSupplementalHeater | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizedSpeed1SupplyAirFlowRateDuringCoolingOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizedSpeed1SupplyAirFlowRateDuringHeatingOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizedSpeed2SupplyAirFlowRateDuringCoolingOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizedSpeed2SupplyAirFlowRateDuringHeatingOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizedSpeed3SupplyAirFlowRateDuringCoolingOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizedSpeed3SupplyAirFlowRateDuringHeatingOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizedSpeed4SupplyAirFlowRateDuringCoolingOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizedSpeed4SupplyAirFlowRateDuringHeatingOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizedSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
void openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizeMaximumSupplyAirTemperaturefromSupplementalHeater | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizeSpeed1SupplyAirFlowRateDuringCoolingOperation | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizeSpeed1SupplyAirFlowRateDuringHeatingOperation | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizeSpeed2SupplyAirFlowRateDuringCoolingOperation | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizeSpeed2SupplyAirFlowRateDuringHeatingOperation | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizeSpeed3SupplyAirFlowRateDuringCoolingOperation | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizeSpeed3SupplyAirFlowRateDuringHeatingOperation | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizeSpeed4SupplyAirFlowRateDuringCoolingOperation | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizeSpeed4SupplyAirFlowRateDuringHeatingOperation | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::autosizeSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) |
double openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::auxiliaryOffCycleElectricPower | ( | ) | const |
double openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::auxiliaryOnCycleElectricPower | ( | ) | const |
boost::optional<Schedule> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::availabilitySchedule | ( | ) | const |
boost::optional<ThermalZone> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::controllingZoneorThermostatLocation | ( | ) | const |
HVACComponent openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::coolingCoil | ( | ) | const |
double openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::designHeatRecoveryWaterFlowRate | ( | ) | const |
HVACComponent openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::heatingCoil | ( | ) | const |
|
static |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::isMaximumSupplyAirTemperaturefromSupplementalHeaterAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::isSpeed1SupplyAirFlowRateDuringCoolingOperationAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::isSpeed1SupplyAirFlowRateDuringHeatingOperationAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::isSpeed2SupplyAirFlowRateDuringCoolingOperationAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::isSpeed2SupplyAirFlowRateDuringHeatingOperationAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::isSpeed3SupplyAirFlowRateDuringCoolingOperationAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::isSpeed3SupplyAirFlowRateDuringHeatingOperationAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::isSpeed4SupplyAirFlowRateDuringCoolingOperationAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::isSpeed4SupplyAirFlowRateDuringHeatingOperationAutosized | ( | ) | const |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::isSupplyAirFlowRateWhenNoCoolingorHeatingisNeededAutosized | ( | ) | const |
double openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ( | ) | const |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::maximumSupplyAirTemperaturefromSupplementalHeater | ( | ) | const |
double openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::maximumTemperatureforHeatRecovery | ( | ) | const |
double openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::minimumOutdoorDryBulbTemperatureforCompressorOperation | ( | ) | const |
int openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::numberofSpeedsforCooling | ( | ) | const |
int openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::numberofSpeedsforHeating | ( | ) | const |
|
default |
|
default |
void openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::resetAvailabilitySchedule | ( | ) |
void openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::resetControllingZoneorThermostatLocation | ( | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setAuxiliaryOffCycleElectricPower | ( | double | auxiliaryOffCycleElectricPower | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setAuxiliaryOnCycleElectricPower | ( | double | auxiliaryOnCycleElectricPower | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setAvailabilitySchedule | ( | Schedule & | schedule | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setControllingZoneorThermostatLocation | ( | const ThermalZone & | thermalZone | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setCoolingCoil | ( | const HVACComponent & | coil | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setDesignHeatRecoveryWaterFlowRate | ( | double | designHeatRecoveryWaterFlowRate | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setHeatingCoil | ( | const HVACComponent & | coil | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setMaximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ( | double | maximumOutdoorDryBulbTemperatureforSupplementalHeaterOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setMaximumSupplyAirTemperaturefromSupplementalHeater | ( | double | maximumSupplyAirTemperaturefromSupplementalHeater | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setMaximumTemperatureforHeatRecovery | ( | double | maximumTemperatureforHeatRecovery | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setMinimumOutdoorDryBulbTemperatureforCompressorOperation | ( | double | minimumOutdoorDryBulbTemperatureforCompressorOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setNumberofSpeedsforCooling | ( | int | numberofSpeedsforCooling | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setNumberofSpeedsforHeating | ( | int | numberofSpeedsforHeating | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSpeed1SupplyAirFlowRateDuringCoolingOperation | ( | double | speed1SupplyAirFlowRateDuringCoolingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSpeed1SupplyAirFlowRateDuringHeatingOperation | ( | double | speed1SupplyAirFlowRateDuringHeatingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSpeed2SupplyAirFlowRateDuringCoolingOperation | ( | double | speed2SupplyAirFlowRateDuringCoolingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSpeed2SupplyAirFlowRateDuringHeatingOperation | ( | double | speed2SupplyAirFlowRateDuringHeatingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSpeed3SupplyAirFlowRateDuringCoolingOperation | ( | double | speed3SupplyAirFlowRateDuringCoolingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSpeed3SupplyAirFlowRateDuringHeatingOperation | ( | double | speed3SupplyAirFlowRateDuringHeatingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSpeed4SupplyAirFlowRateDuringCoolingOperation | ( | double | speed4SupplyAirFlowRateDuringCoolingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSpeed4SupplyAirFlowRateDuringHeatingOperation | ( | double | speed4SupplyAirFlowRateDuringHeatingOperation | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSupplementalHeatingCoil | ( | const HVACComponent & | coil | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSupplyAirFan | ( | const HVACComponent & | fan | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSupplyAirFanOperatingModeSchedule | ( | Schedule & | schedule | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSupplyAirFanPlacement | ( | const std::string & | supplyAirFanPlacement | ) |
bool openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::setSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | double | supplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ) |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::speed1SupplyAirFlowRateDuringCoolingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Speed 1 Supply Air Flow Rate".
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::speed1SupplyAirFlowRateDuringHeatingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Speed 1 Supply Air Flow Rate".
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::speed2SupplyAirFlowRateDuringCoolingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Speed 2 Supply Air Flow Rate".
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::speed2SupplyAirFlowRateDuringHeatingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Speed 2 Supply Air Flow Rate".
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::speed3SupplyAirFlowRateDuringCoolingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Speed 3 Supply Air Flow Rate".
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::speed3SupplyAirFlowRateDuringHeatingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Speed 3 Supply Air Flow Rate".
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::speed4SupplyAirFlowRateDuringCoolingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Cooling Speed 4 Supply Air Flow Rate".
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::speed4SupplyAirFlowRateDuringHeatingOperation | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "Heating Speed 4 Supply Air Flow Rate".
HVACComponent openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::supplementalHeatingCoil | ( | ) | const |
HVACComponent openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::supplyAirFan | ( | ) | const |
Schedule openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::supplyAirFanOperatingModeSchedule | ( | ) | const |
std::string openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::supplyAirFanPlacement | ( | ) | const |
|
static |
boost::optional<double> openstudio::model::AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed::supplyAirFlowRateWhenNoCoolingorHeatingisNeeded | ( | ) | const |
In EnergyPlus 8.3.0 and above this property maps to the EnergyPlus field "No Load Supply Air Flow Rate".
|
related |
|